GENMAX GM2800iA Portable Inverter Generator User Manual

June 9, 2024
GENMAX

GM2800iA Portable Inverter Generator

R
USER MANUAL

FOR MODELS:

GM2800iA/GM2800iAE
Portable Inverter Generator
2500 Running Watts | 2800 Peak Watts

GM3500iA/GM3500iAE/GM3500iAED
Portable Inverter Generator
3200(GAS.)/2800(LPG) Running Watts | 3500(GAS.)/3100(LPG) Peak Watts

CHONGQING DINKING POWER MACHINERY CO., LTD

GM2800iA GM2800iAE GM3500iA GM3500iAE GM3500iAED

(Gal)

2500 2800 1.58

2500 2800 1.58

3200 3500 1.58

3200
3200(GAS.) 2800(LPG)

3500 1.58

3500(GAS.) 3100(LPG)

1.58

4500 4500 4850 4850 4850

A5RTC 145 A5RTC 145 A5RTC 145 A5RTC 145 A5RTC 145

64×45 64×45 64×45 64×45 64×45

(Gal)
0.12 0.12 0.12 0.12 0.12

10W30 10W30 10W30 10W30 10W30

2

LIMITED WARRANTY

Email: warrantiessmallengines@gmail.com

Phone: 866-960-2920

WARRANTY CARD

Name: ___ Model Number:


Street Address: ___ Serial Number:__

City, State, ZIP:____ Date Purchased:


Country: __ Purchased From:____

Phone Number: ___

R

E-Mail: ___

3

17

LIMITED WARRANTY

17

Warranty Card

18

18

18

19

19

19

20

21

22

22

22

23

11 11

SCHEMATICS

24

11

11

11

11

GENMAX

11

12

12

13

14

14

14

15

16

16

16

4

Connection of the product to a building’s electrical system is not applicable.
5

6

SAFETY LABELS AND DECALS 6
6
Three-prong Plug (1)
7

BASIC INVERTER FEATURES
7 3
Fuel Cap: Open the fuel tank cap and fill with proper amount of gasoline.
8

10 9
4 2

GM2800iA/GM3500iA

USB Duplex: 5V DC that come in 1 amps and 2.1 amps.
120-Volt, 30-Amp Outlet (L5-30): The outlet is capable of carrying a maximum of 30 amps. Multifunctional LED Digital Display Meter: Red light (LOW OIL) means that the amount of oil is too low, red light (OVERLOAD) means that the machine overload, green light (POWER) means normal operation. LED Digital Display shows time, voltage, power, frequency and oil level; Time: scrolling display of single running time and accumulated running time; voltage: scrolling display of 120V and 240V. Efficiency Mode Switch: When turned to the ON position, the engine will sense the load needed and run at a slower RPM to save fuel.

Parallel Connectors: To increase AC power output, the connector sockets are used to connect the two same type generator with special paralleling cords. The connector sockets is only used to the communication between the inverters, they cannot used for AC power output. The special paralleling cords shall be purchase separately, and they shall be approved by certification body. AC Protector: If the inverter is overload, the AC protector will trip to block current. 10 CO Alarm : Flashing red light: dangerous levels of carbon monoxide gas have built up leave immediately until area has aired out. Move generator to well-ventilated area before operation. Flashing yellow light: carbon monoxide sensor malfunction. Sensor needs service.

9

4
11 2

9

10

GM2800iAE/GM3500iAE/GM3500iAED

USB Duplex: 5V DC that come in 1 amps and 2.1 amps.
One Push Start: Press this button, the engine can start and stop. Press this button for 3-5 seconds until the green light is on, and then press the ON/OFF button on the remote control key until the light is off. At this time, the remote control matches successfully. Multifunctional LED Digital Display Meter: Red light (LOW OIL) means that the amount of oil is too low, red light (OVERLOAD) means that the machine overload, green light (POWER) means normal operation. LED Digital Display shows time, voltage, power, frequency and oil level; Time: scrolling display of single running time and accumulated running time; voltage: scrolling display of 120V and 240V.

Efficiency Mode Switch: When turned to the ON position, the engine will sense the load needed and run at a slower RPM to save fuel.
Parallel Connectors: To increase AC power output, the connector sockets are used to connect the two same type generator with special paralleling cords. The connector sockets is only used to the communication between the inverters, they cannot used for AC power output. The special paralleling cords shall be purchase separately, and they shall be approved by certification body. AC Protector: If the inverter is overload, the AC protector will trip to block current. 10 CO Alarm : Flashing red light: dangerous levels of carbon monoxide gas have built up leave immediately until area has aired out. Move generator to well-ventilated area before operation. Flashing yellow light: carbon monoxide sensor malfunction. Sensor needs service. 11 120-Volt, 30-Amp Outlet (L5-30): The outlet is capable of carrying a maximum of 30 amps.

10

GENMAX
Carbon Monoxide Specification CO DETECT technology monitors the accumulation of carbon monoxide (CO), a poisonous gas produced by engine exhaust when the generator is running. If CO Sensor detects unsafe elevated levels of CO gas, it automatically shuts off the engine. CO Sensor is not a substitute for an indoor carbon monoxide alarm or for safe operation. DO NOT allow engine exhaust fumes to enter a confined area through windows, doors, vents or other openings. Generators must ALWAYS be used outdoors, far away from occupied buildings with engine exhaust pointed away from people and buildings. Meets the requirements of ANSI/PGMA G300-2018.
11

GENMAX

GENMAX

GENMAX

12

Loosen the knob on the right exterior cover and remove the right exterior cover (see Figure 1).
13

14

10 10
10 10
Recoil Starter 1. Remove all the loads out of the output; 2. Turn the fuel switch to “ON”; 3. Turn the engine switch to “ON”; 4. Firmly grasp and pull the recoil handle slowly until you feel increased resistance. At this point, apply a rapid pull while pulling out from the inverter. Pull the Recoil Handle out from Inverter (see Figure 6). Tip: When pulling the hand starter, hold the generator carrying handle firmly, to prevent the generator from overturning.

Figure 6 Electric Starting 1. Remove all the loads out of the output. 2. Turn the fuel switch to “ON”. 3. Press “START UP” to START the generator.
Remote Start 1. Remove all the loads out of the output. 2. Turn the fuel switch to “ON”. 3. Press “ON” on the remote control for 1 second and the generator runs normally.
Remote Control Pairing 1. Press the “START” button for 5 seconds, release it when the “START/MATCH” indicator lights up. 2. Press “ON”/”OFF” on the remote control until the indicator lights off. 3. Press “ON” on the remote control for 1 second, when the generator starts, the function is paired successfully. Tip: The remote control supplied with the generator has been paired successfully.
Dual Fuel 1. Using fuel oil: Turn the oil/gas switch to GAS., and then start and run the generator according to normal start-up steps; 2. Use gas: turn the oil and gas conversion switch to gas, open the gas cylinder, press the thickening valve button on the secondary pressure reducing valve, and start the generator according to the normal start-up steps. Procedure For Connecting Gas Pipes 1. Connect the pressure reducing valve assembly to the gas tank and tighten it; 2. Connect the dedicated gas hose to the generator; 3. Switch the oil/gas switch to gas gear; 4. Open the gas valve on the fuel tank and start the generator according to the normal start-up steps.

15

1. Remove all the loads out of the output. 3. Turn off the fuel (or gas) switch. 2. Press “START UP” to stop the generator. To stop the engine in an emergency, please directly press “START UP” to stop the generator.

(see Figure 7).

Figure 7

16

17

Figure 8.

Figure 8

Figure 8.

18

(see Figure 9).

Figure 9

(see Figure 11).

Figure 10

Figure 11
19

(see Figure 12). Figure 12

Figure 13

(see Figure 14)

Figure 14
(see Figure 13).
20

3. Unscrew the bolts and remove the left exterior cover plate (see Figure 15).
Figure 15
(see Figure 16). Figure 16
21

(see Figure 17). Figure 17
22

23

GM2800iA/GM3500iA
24

GM2800iAE/GM3500iAE
25

GM3500iAED
26

R
CHONGQING DINKING POWER MACHINERY CO.,LTD. CAOJIE DEVELOPMENT AREA, INDUSTRIAL PARK, HECHUAN, CHONGQING, CHINA
27
6800.J05.GEM.02.00 V1

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals