GENMAX GM1200i Digital Inverter Generator User Manual
- June 9, 2024
- GENMAX
Table of Contents
GM1200i Digital Inverter Generator
R
USER MANUAL
FOR MODELS:
GM1200i
Digital Inverter Generator
1000 Running Watts | 1200 Peak Watts
CHONGQING DINKING POWER MACHINERY CO., LTD
GM1200i
1000
1200
(Gel)
0.6
4500
A5RTC 57
45×36
(Gel)
0.08
10W30
NEUTRAL FLOATING
For portable generators where the neutral is floating, the operator’s manual
shall include the following wording or equivalent:
The portable generator stator winding is isolated from the frame and from the
AC receptacle ground pin; and Electrical devices that require a connection
between one conductor pin and the grounded receptacle pin may not function
properly.
2
LIMITED WARRANTY
Email: warrantiessmallengines@gmail.com
Phone: 866-960-2920
WARRANTY CARD
Name: ___ Model Number:
Street Address: ___ Serial Number:__
City, State, ZIP:____ Date Purchased:
Country: __ Purchased From:____
Phone Number: ___
R
E-Mail: ___ 3
16
LIMITED WARRANTY
16
Warranty Card
17
17
17
18
18
18
19
20
21
21
GM1200i
21
GM1200i
22
10
10
10
10
10
10
GENMAX
10
11
11
12
13
13
13
GM1200i
14
15
15
15
4
Connection of the product to a building’s electrical system is not applicable.
5
6
SAFETY LABELS AND DECALS GM1200i
RV30 Plug(1) 7
BASIC INVERTER FEATURES GM1200i 3
9 10
Fuel Cap and Vent: Open the vent to run the engine and close the vent when the
engine is off.
9 Choke Switch: when cold start, properly close part of the air inlet to
improve the engine start performance, after normal operation, the choke should
be fully open, otherwise the engine can not run properly because of too thick
mixture and cause too much oil consumption.
10 Fuel Switch: FuelswitchisOFF,andtheenginewill not run.
8
12
9
10
11
GM1200i
Low Oil Alarm: Indicates low oil level. Overload Alarm: Indicates that the
inverter is overloaded. Output Indicator: Indicates the inverter is ready to
be used.
CO Alarm : Flashing red light: dangerous levels of carbon monoxide gas have
built up leave immediately until area has aired out. Move generator to well-
ventilated area before operation. Flashing yellow light: carbon monoxide
sensor malfunction. Sensor needs service. 10 AC Breaker:
to block current.
11 Parallel Connectors:To increase AC power output, the connector sockets are
used to connect the two same type generator with special paralleling cords.
The connector sockets is only used to the communication between the inverters,
they can not used for AC power output. The special paralleling cords shall be
purchase separately, and they shall be approved by certification body.
12 Engine Switch: Press ON to start the engine, press OFF to turn OFF the
engine
9
GENMAX
10
GENMAX
GENMAX
GENMAX
11
12
13
Turn the choke handle to the right to the “closed” position (see Figure 7).
CHOKE open
closed
Starting GM1200i
2. Turn off switch to “ON” . 3.
6. After generator starts, turn choke switch left to “open” state (see Figure 9).
CHOKE open
closed
14
Turn the flameout switch to OFF. Stop all the electric equipment. Put the cap
ventilate button to OFF”position when the generator totally cold. Figure 10:
Turn Engine Switch to OFF Position
15
16
17
18
19
20
21
22
GM1200i
23
R
CHONGQING DINKING POWER MACHINERY CO.,LTD. CAOJIE DEVELOPMENT AREA,
INDUSTRIA2L4 PARK, HECHUAN, CHONGQING, CHINA
6800.446.GEM.02.00 V3