Cell2 AL6 Wide Angle Lighthead User Manual
- June 9, 2024
- Cell2
Table of Contents
Cell2 AL6 Wide Angle Lighthead
Surface Mounting
WIRING
OPERATION
For Simultaneous or Alternating Flash:
-
Apply +VDC to RED and YELLOW wires simultaneously to enter Grouping mode; lighthead will display short (single or double) flashes:
Single flash = Group1
Double flash = Group2 -
Remove YELLOW wire from +VDC then momentarily apply +VDC to change Groups:
Heads of the same Group will flash together.
Heads of different Groups will flash alternately. -
Save and Exit the Grouping Mode by powering off the lighthead.
For Flash Patterns:
Momentarily apply +VDC to YELLOW wire:
once for next pattern
quick three times for FP#1
NOTE: This unit may not be factory set at FP# 1.
FLASH PATTERNS
1| Double [R65]| 9| Double [SAE]
2| Single [2Hz]| 10| Triple [SAE]
3| Triple [2Hz]| 11| Quad [SAE]
4| Quad [2Hz]| 12| Quint [SAE]
5| Random| 13| Ultra [SAE]
6| Steady| 14| Single-Quad
7| Single [SAE][CA13]| 15| Single H/L
8| Mega [SAE]| 16| Singe-Triple-Quint
Side Mirror Mounting
ADJUSTABLE RANGE FOR SIDE MIRROR MOUNT
- Up-down tilting: ±8°
- Left-right tilting: ±8°
- Height Adjustment: 8mm
Side Mirror Mounting
Notes when Mounting with back Cover
-
Please ensure that the wires should exit from the side without the groove A
-
Please break away the drainage notch B with pliers. (Not required for pedestal mount)
-
Select a mounting location and install the Bracket 1 to mirror.
-
Attach the Bracket 2 to the Lighthead.
NOTE: You may adjust the height and Left-Right tilting at this point.
- Feed the wires through the cable grommet and assemble the Bracket 1 with Bracket 2.
NOTE: You may adjust the Up-down tilting at this point.
- Secure the back Cover with the screw and the rubber stud.