DUAL COLOUR   3+3 LED DUAL COLOUR LIGHTHEAD

WIRING
  1. To Chassis Ground: ……………………………….. BLACK

  2. To+VDC for Warning Mode (1) (fuse @ 1A): ……… RED
    Default Colour Mode – Colour 1

  3. To+VDC for Warning Mode (2) (fuse @ 1A): ….. WHITE
    Default Colour Mode – Colour 2
    (To+VDC for Warning Mode (3): ……….. RED+WHITE)
    Default Colour Mode – Colour 1 alt. 2
    Order of Precedence: Mode (3) > Mode (1) = Mode (2) > Cruise Mode

  4. To+VDC for Cruise Mode (fuse @ 1A): ……….. GREEN

  5. For Synchronization and Flash Pattern:YELLOW
    Connect YELLOW wires of all lightheads together for synchronization.
    (All lightheads should be set to the same Flash Pattern)

OPERATION
For Flash Pattern Selection:

Each Warning Mode may select and save one Flash Pattern. While activating a Warning Mode, momentarily apply YELLOW wire to +VDC :

  • Once to next pattern.
  • Quick three times to the default Flash Pattern (FP#1).
    (refer to Flash Pattern Chart)
For Simultaneous or Alternating Synchronization:
  1. Apply +VDC to RED (or WHITE or RED+WHITE ) and YELLOW wires simultaneously to enter SETTING MODE; the lighthead will display short flashes:
    • Single flash = Group 1      • Double flash = Group 2

  2. Remove YELLOW wire from +VDC then momentarily apply to +VDC again for more than 3 seconds to change Groups:
    • Lightheads of the same Group will flash together.
    • Lightheads of the different Group will flash alternately.

  3. Save and exit SETTING MODE by disconnecting all power.

NOTE: All warning modes share the same Group setting.

For Color Mode Setting:
  1. Each Warning Memory may select and save one Colour Mode. Apply +VDC to RED (or WHITE or RED+WHITE ) and YELLOW wires simultaneously to enter SETTING MODE; the lighthead will display its current Colour Mode:
    • Single Colour flashing Color 1    = Color 1
    • Single Colour flashing Color 2    = Color 2
    • Dual Colour flashing Color 1      = Color 1 alt. 2
    • Dual Colour flashing Color 2      = Color 2 alt. 1

  2. Remove YELLOW wire from +VDC then momentarily apply to +VDC for less than 3 seconds to change Colour Mode.

  3. Save and exit SETTING MODE by disconnecting all power.

Reset to Factory Default Settings:
  1. Apply +VDC to RED (or WHITE or RED+WHITE ) and YELLOW wires simultaneously to enter SETTING MODE;
  2. Remove YELLOW wire from +VDC then momentarily apply to +VDC again for more than 5 seconds. The lighthead will display fast short flashes to signify restoring successfully.
  3. Save and exit SETTING MODE by disconnecting all power.

Flash Pattern (Dual Colour)


1

| Double  [2Hz]|

8

| Double [SAE]|

15

| Single-Quad|

22

| Triple-Triple Fast

2

| Single    [2Hz]|

9

| Triple    [SAE]|

16

| Single H/L|

23

| Quint-Triple

3

| Triple    [2Hz]|

10

| Quad    [SAE]|

17

| Single-Triple-Quint|

24

| 7-1 Flash

4

| Quad     [2Hz]|

11

| Quint    [SAE]|

18

| Steady Scene|

25

| 7-1 Flash #

5

| Random|

12

| Mega|

19

| Single-Single|

26

| Quad-Single

6

| Steady EF*|

13

| Giga|

20

| Double-Double|

27

| Quad-Single#

7

| Single    [SAE][CA13]|

14

| Ultra     [SAE]|

21

| Triple-Triple Mid|

28

| Quint-Quint

FP#19~28 will always operate in dual colour.

  • For use with external flash controller.    # Inverted colour mode.

SINGLE COLOUR   6 LED SINGLE COLOUR LIGHTHEAD

WIRING
  1. To Chassis Ground: …………………………………. BLACK

  2. To+VDC for Warning Mode (fuse @ 2A): …………… RED
    Apply +VDC to RED wire for High Power Operation (100%).

  3. For Low Power Operation: ………………………… WHITE
    Apply +VDC to WHITE wire while RED wire is activated for Low Power Operation (40%).

  4. To+VDC for Cruise Mode (fuse @ 2A): ………… GREEN
    Order of Precedence: Warning Mode > Cruise Mode

  5. For Synchronization and Flash Pattern: …. YELLOW
    Connect YELLOW wires of all lightheads together for synchronization.
    (All lightheads should be set to the same Flash Pattern)

OPERATION
For Flash Pattern Selection:

Each Warning Mode may select and save one Flash Pattern. While activating a Warning Mode, momentarily apply YELLOW wire to +VDC :

  • Once to next pattern.
  • Quick three times to the default Flash Pattern (FP#1).
    (refer to Flash Pattern Chart)
For Simultaneous or Alternating Synchronization:
  1. Apply +VDC to RED and YELLOW wires simultaneously to enter SETTING MODE; the lighthead will display short flashes:
    • Single flash = Group 1
    • Double flash = Group 2

  2. Remove YELLOW wire from +VDC then momentarily apply to +VDC again for more than 3 seconds to change Groups:
    • Lightheads of the same Group will flash together.
    • Lightheads of the different Group will flash alternately.

  3. Save and exit SETTING MODE by disconnecting all power.

Reset to Factory Default Settings:
  1. Apply +VDC to RED and YELLOW wires simultaneously to enter SETTING MODE;
  2. Remove YELLOW wire from +VDC then momentarily apply to +VDC again for more than 5 seconds. The lighthead will display fast short flashes to signify restoring successfully.
  3. Save and exit SETTING MODE by disconnecting all power.

Flash Pattern (Single Colour)


1

| Double    [2Hz]|

10

| Quad       [SAE]

2

| Single      [2Hz]|

11

| Quint      [SAE]

3

| Triple      [2Hz]|

12

| Mega

4

| Quad       [2Hz]|

13

| Giga

5

| Random|

14

| Ultra        [SAE]

6

| Steady EF*|

15

| Single-Quad

7

| Single       [SAE][CA13]|

16

| Single H/L

8

| Double    [SAE]|

17

| Single-Triple-Quint

9

| Triple      [SAE]|

18

| Steady Scene

  • For use with external flash controller.
INSTALLATION
Universal Bracket (Multi-Angle)

NOTE:
Tighten the mounting bolts with the suggested range of torque value: 7.5~15 kgf-cm (6.5~13 lbf-in).

  1. Spring Washer
  2. Hex Nut
  3. Flat Washer
  4. Mounting Surface
  5. Universal Bracket
  6. Mounting Bolt

OR

  1. Mounting Bolt
  2. Universal Bracket
  3. Spring Washer
  4. Hex Nut
  5. Flat Washer
  6. Mounting Surface
Adjustable Bracket (Optional)

The angle of lighthead is adjustable up to 20 degree for optimum warning efficiency.

Case (1)

Cell2 ED6 - INSTALLATION 3

  1. Mounting Surface

OR

Case (2)

Cell2 ED6 - INSTALLATION 4

  1. Mounting Surface

NOTE:
Tighten the mounting bolts with the suggested range of torque value: 7.5~15 kgf-cm (6.5~13 lbf-in).

NOTE:
Apply the blackout tapes to avoid back-flash.

  1. Case (1): Mounting Screw
  2. Case (1): Toothed Washer
  3. Blackout Tape
  4. Case (2): Hex Bolt
  5. Foam Tape
  6. Adjustable Bracket
  7. Mounting Bolt
L-Bracket (Front / Rear)

NOTE:
Tighten the mounting bolts with the suggested range of torque value: 7.5~15 kgf-cm (6.5~13 lbf-in).

Cell2 ED6 - INSTALLATION 6

  1. Mounting Bolt
  2. L-Bracket
  3. Spring Washer
  4. Flat Washer
  5. Hex Nut
  6. Mounting Surface

OR

  1. Mounting surface
  2. Hex Nut
  3. Flat Washer
  4. Spring Washer
  5. L-Bracket
  6. Mounting Bolt