WIRING & OPERATION
-
RED : To +VDC
BLACK : To Chassis Ground (-) -
WHITE : For Simultaneous or Alternating Flash
- Group1 Units : (Wiring- \WJ[H]~’jj’~ connected to RED) will flash together.
- Group2 Units : (Wiring- \WJ[H]~’jj’~ not connected to RED) will flash together.
- Group1 Units will alternate with Group2 Units*
-
YELLOW: Flash patterns & Synchronization Connect Y OW wires of all heads together for synchronization.
All heads must be set at the same pattern.- Momentarily apply +VDC to Y ___ ow wire : once for next pattern. quick 3 times for reset.
3 Bolt Mount
FLASH PATTERN CHANGE
- Open
- Push down on Tab A , and twist the dome counterclockwise 1 , then lift the dome to open.
- Change
- While activating Warning Mode, momentarily push the RED BUTTON 2 ) to change to the next flash pattern. (see Flash Patterns chart)
- Close
- Magnetic Mount / Bolt Mount Align dome indent B ) before Tab A , then twist clockwise 3 to close.
NOTE
- This unit may not be factory-set at FP#1
- Actual approval base on the model ordered.
FP# | FLASH PATTERNS |
---|---|
Double [R65 2Hz] | |
2 | Single [2Hz] |
3 | Quad [2Hz] |
4 | Single [SAE] |
5 | Double [SAE] |
6 | Quad [SAE] |
7 | Quint [SAE] |
8 | Mega |
9 | Ultra [SAE] |
10 | Single-Quad |
11 | Single H/L |
12 | Single Column Rotator |
13 | Double Column Rotator |
14 | Double Rotator x5 -> Quint x5 |