Cell2 CR06-DC Led Flush Mount Kit User Manual
- June 9, 2024
- Cell2
Table of Contents
Cell2 CR06-DC Led Flush Mount Kit
WIRING
OPERATION
For Flash Pattern Selection
While in Warning Mode, momentarily apply +VDC to YELLOW wire:
- once to next pattern
- quickly three times to FP#1 (Refer ro Flash Pattern Chart)
For Simultaneous or Alternating Flash
- Apply +VDC to RED and YELLOW wires simultaneously to enter SETTING MODE; lighthead will display short (single or double) flashes:
- Single flash = Group 1
- Double flash = Group 2
- Remove YELLOW wire from +VDC then momentarily apply +VDC again for more than 3 seconds to change Groups.
- Lightheads of the same Group will flash together.
- Lightheads of different Groups will flash alternately.
- Save and Exit the SETTING MODE by powering off the lighthead.
NOTE : All warning memories share the same Group setting.
For Color Mode Setting
- Apply +VDC to RED and YELLOW wires simultaneously to enter SETTING MODE; lighthead will display short (single or double) flashes:
- Single Color flashing Color 1 = Color1
- Single Color flashing Color 2 = Color2
- Dual Color flashing Color 1 = Color1 alt 2
- Dual Color flashing Color 2 = Color2 alt 1
- Remove YELLOW wire from +VDC then momentarily apply +VDC again for less than 3 seconds to change Color Mode.
- Save and Exit the SETTING MODE by powering off the lighthead.
Reset to Factory Default Settings
-
Apply +VDC to RED and YELLOW wires simultaneously to enter SETTING MODE
-
Remove YELLOW wire from +VDC then momentarily apply to +VDC again more than 5 seconds.
The lighthead will display fast shrot flashers to signify restoring successfully. -
Save and Exit the SETTING MODE by powering off the lighthead
Flash Pattern1| Double| [R65*]| 8| Double| [SAE]| 15| Single-Quad| 22| Triple-Triple Fast
2| Single| [2Hz]| 9| Triple| [SAE]| 16| Single H/L| 23| Quint-Triple
3| Triple| [2Hz]| 10| Quad| [SAE]| 17| Single-Triple-Quint| 24| 7-1 Flash
4| Quad| [2Hz]| 11| Quint| [SAE]| 18| Steady Scene| 25| 7-1 Flash #
5| Random| 12| Mega| 19| Single-Single| 26| Quad-Single
6| Steady EF**| 13| Giga| 20| Double-Double| 27| Quad-Single#
7| Single| [SAE][CA13]| 14| Ultra| [SAE]| 21| Triple-Triple Mid| 28| Quint- Quint
FP19~28 will aways operate in dual color.
Inverted color mode.
Actual approval will be based on the model ordered.
For use with external flash controller
INSTALLATION
Pop-n-Lock
Recommended Surface thickness @1.5~4.0mm
-
Select a mounting location and drill an 1.14” (29mm) cut-out, and then install the LIGHTHEAD onto the cut-out.
NOTE : To install more efficiently, use a rotating motion to guide the LIGHTHEAD when installing onto the cut-out. -
Ensure that the optical stripes are aligned vertically
-
Where necessary, apply silicone around the reverse side to prevent from rotating
Bracket Mount
-
From the front, install the LIGHTHEAD onto the BRACKET.
-
Ensure that the optical stripes are aligned vertically.
NOTE: To install more efficiently, use a rotating motion to guide the LIGHTHEAD when installing onto the BRACKET.
Secure the BRACKET onto the desired mounting surface with screws.: To install more efficiently, use a rotating motion to guide the LIGHTHEAD when installing onto the BRACKET. -
Secure the BRACKET onto the desired mounting surface with screws.
-
Where necessary, apply silicone around the reverse side to prevent from rotating.