Cell2 CR06-DC Led Flush Mount Kit User Manual

June 9, 2024
Cell2

Cell2 CR06-DC Led Flush Mount Kit

WIRING

OPERATION

For Flash Pattern Selection
While in Warning Mode, momentarily apply +VDC to YELLOW wire:

  • once to next pattern
  • quickly three times to FP#1 (Refer ro Flash Pattern Chart)

For Simultaneous or Alternating Flash

  1. Apply +VDC to RED and YELLOW wires simultaneously to enter SETTING MODE; lighthead will display short (single or double) flashes:
  2. Single flash = Group 1
  3. Double flash = Group 2
  4. Remove YELLOW wire from +VDC then momentarily apply +VDC again for more than 3 seconds to change Groups.
  5. Lightheads of the same Group will flash together.
  6. Lightheads of different Groups will flash alternately.
  7. Save and Exit the SETTING MODE by powering off the lighthead.
    NOTE : All warning memories share the same Group setting.

For Color Mode Setting

  1. Apply +VDC to RED and YELLOW wires simultaneously to enter SETTING MODE; lighthead will display short (single or double) flashes:
  2. Single Color flashing Color 1 = Color1
  3. Single Color flashing Color 2 = Color2
  4. Dual Color flashing Color 1 = Color1 alt 2
  5. Dual Color flashing Color 2 = Color2 alt 1
  6. Remove YELLOW wire from +VDC then momentarily apply +VDC again for less than 3 seconds to change Color Mode.
  7. Save and Exit the SETTING MODE by powering off the lighthead.

Reset to Factory Default Settings

  1. Apply +VDC to RED and YELLOW wires simultaneously to enter SETTING MODE

  2. Remove YELLOW wire from +VDC then momentarily apply to +VDC again more than 5 seconds.
    The lighthead will display fast shrot flashers to signify restoring successfully.

  3. Save and Exit the SETTING MODE by powering off the lighthead
    Flash Pattern

    1| Double| [R65*]| 8| Double| [SAE]| 15| Single-Quad| 22| Triple-Triple Fast
    2| Single| [2Hz]| 9| Triple| [SAE]| 16| Single H/L| 23| Quint-Triple
    3| Triple| [2Hz]| 10| Quad| [SAE]| 17| Single-Triple-Quint| 24| 7-1 Flash
    4| Quad| [2Hz]| 11| Quint| [SAE]| 18| Steady Scene| 25| 7-1 Flash #
    5| Random| 12| Mega| 19| Single-Single| 26| Quad-Single
    6| Steady EF**| 13| Giga| 20| Double-Double| 27| Quad-Single#
    7| Single| [SAE][CA13]| 14| Ultra| [SAE]| 21| Triple-Triple Mid| 28| Quint- Quint

FP19~28 will aways operate in dual color.
Inverted color mode.
Actual approval will be based on the model ordered.
For use with external flash controller

INSTALLATION

Pop-n-Lock

Recommended Surface thickness @1.5~4.0mm

  1. Select a mounting location and drill an 1.14” (29mm) cut-out, and then install the LIGHTHEAD onto the cut-out.
    NOTE : To install more efficiently, use a rotating motion to guide the LIGHTHEAD when installing onto the cut-out.

  2. Ensure that the optical stripes are aligned vertically

  3. Where necessary, apply silicone around the reverse side to prevent from rotating

Bracket Mount

  1. From the front, install the LIGHTHEAD onto the BRACKET.

  2. Ensure that the optical stripes are aligned vertically.
    NOTE: To install more efficiently, use a rotating motion to guide the LIGHTHEAD when installing onto the BRACKET.
    Secure the BRACKET onto the desired mounting surface with screws.: To install more efficiently, use a rotating motion to guide the LIGHTHEAD when installing onto the BRACKET.

  3. Secure the BRACKET onto the desired mounting surface with screws.

  4. Where necessary, apply silicone around the reverse side to prevent from rotating.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals