Cell2 RAYZR Lighthead 3LED TIR User Manual
- June 9, 2024
- Cell2
Table of Contents
RAYZR Lighthead 3LED TIR
User Manual
RAYZR Lighthead 3LED TIR
WIRING FOR WARNING STICKS
RED ……………………[+] Warning Mode to +VDC with rated fuse (for correct rating,
refer to the Fuse Rating Chart)
BLACK …………………to Chassis ground
Fuse Rating
2-Head Model = 2 Amps| 4-Head Model = 3 Amps
YELLOW………………. [+] Flash Pattern Selection (refer to Flash Patterns chart) / Synchronization Momentarily apply +VDC to YELLOW wire:
- Once to next pattern
- Quick 3 times to FP#1
Connect YELLOW wires of all sticks together for synchronization All
sticks should be set to the same pattern
WHOTE …………………………..[+] for Simultaneous or Alternating Flash (for multi-
sticks only)
Group1 – Sticks with WHOTE connected to +VDC will flash together
Group2 – Sticks with WHOTE not connected to +VDC will flash together
Group1 will alternate with Group2
Warning Stick Flash Patterns
1| Kit Scan| 10| [Left-Right] Single| 19| [All] Quint
2| Kit Scan + Double| 11| [Left-Right] Double 2Hz| 20| [Ali] Ultra
3| [wig-wag] Slow-Fast| 12| [Left-Right] Quint| 21| rem Single-Quad
4| [Outside-In] Single| 13| [Left-Right] Ultra| 22| [All] Single H/L
5| (Outside-In] Ultra| 14| [Left-Right] Single-Quad| 23| [All] Quint + (Left-
eight] Mega
6| [Side-by-Side] Single| 15| (Left-Right] Single H/L| 24| [Half] Steady Half
7| [SIde-by-Side] Ultra| 16| [Left-Right] Quint + [All] Mega| 25| [Ali] Steady
All
8| [Side-by-Side] Slow-Fast| 17| [All) Single| 26| Left Chaser
9| Random| 18| [All) Double 2Hz| 27| Right Chaser
WIRING FOR TRAFFIC ADVISOR WARNING STICK
RED ……………….. to +VDC with rated fuse (for correct rating, refer to the
Fuse Rating Chart)
BLACK …………………….to Chassis ground
Fuse Rating
6-Head Model = 4 Amps
10-Head Model = 7 Amps
8-Head Model = 6 Amps
BLUE……………………. [+] Rear “Left Arrow” [122] | Rear”Centre Out Arrow” [P1] |
---|
ORANGE……………… [+] Rear “Right Arrow” [P2]
BROWN ……………. [+] Warning Mode [P3] GREEN …………….[+] Low Power Operation or [+] End-Flasher See “Firmware Selection” for End-Flasher Mode.
End Flasher Patterns ( Green )
1| Double [2Hz] (all)
2| Quad [2Hz] (all)
3| Single [2Hz] (all)
4| Double [2Hz] (split)
5| Quad [2Hz] (split)
6| Single [2Hz] (split)
WHITE………….. [ ] Control Panel Indicator Signal out (connect to a
compatible Control Panel)
YELLOW…………….. [+] Flash Pattern Selection (refer to respective pattern
chart) While End-Flasher, Traffic Advising or Warning Mode is activated,
Momentarily apply +VDC to YELLOW wire:
- Once to next pattern
- Quick 3 times to FP#1
NOTE: [Px] = Precedence order, when more than a wire is activated at the
same time, higher priority wire will affect lower priority wire. P1 being the
highest priority.
End Flasher Patterns (Green) 1 Double [2Hz] (all) 2 Quad [2Hz] (all) 3 Single
[2Hz] (all) 4 Double [2Hz] (split) 5 Quad [2Hz] (split) 6 Single [2Hz] (split)
Traffic Advisor Warning Stick Patterns (Brown)
1| Random / Custom| 11| [Wig-wag] Slow-Fast
2| Random Standard| 12| [Left-Right] Single
3| [Outside-In] Single| 13| [Left-Right] Ultra
4| [Outside-In] Ultra| 14| [Left-Right] Single H/L
5| [Side-by-Side] Single| 15| [Left-Right] Quint + [All] Mega
6| [Side-by-Side] Ultra| 16| [All] Single
7| [Side-by-Side] Slow-Fast| 17| [All] Double
8| Kit Scan| 18| [All] Ultra
9| Kit Scan Split| 19| [All] Quint + [Left-Right] Mega
10| Kit Scan Dual + Double| 20| [All] Steady
Arrow Patterns (Orange / Blue)
1| Sweep Single
2| Sweep Double
3| Sweep Triple
4| Sweep Single End x2
5| Solid
6| Solid End x2
7| Solid Chaser
8| Solid Fade
9| Blink Double
10| Blink Triple
11| Blink Solid
FIRMWARE SELECTION FOR TRAFFIC ADVISOR WARNING STICK
All Traffic Advisor Warning Stick come with built-in selectable firmwares. To change firmware:
- Apply +VDC to RED, = and GREEN wires simultaneously then remove GREEN wire from +VDC to enter FIRMWARE selection.
- Once in FIRMWARE selection mode, the unit will display one of the following patterns.
- Momentarily apply GREEN wire to +VDC to change FIRMWARE. 4. Once a desired FIRMWARE is selected, save and exit by disconnect all power.
CUSTOM PATTERN PROGRAMMING FOR TRAFFIC ADVISOR WARNING STICK
PROGRAMMING FP#1 Random Custom pattern from Warning Patterns can be
customized. This can only be done through firmware that is set to Traffic
Arrow.
To configure FP#1 flash pattern:
-
Activate Warning Patterns by applying +VDC to BROWN wire.
-
Scroll to flash pattern FP#1 by quickly tapping +VDC 3 times to YELLOW wire .
-
Enter PROGRAMMING by quickly tapping +VDC 3 times to GREEN wire.
-
Once in PROGRAMMING, all lightheads will faintly blink once every second. The center pair of lightheads will be activated.
-
Tap +VDC to YELLOW wire:
• Once for next pattern (see Lighthead Pattern Chart).
• Quick 3 times for FP#1. -
Scroll to the next pair of lightheads by tapping +VDC to GREEN wire.
-
Repeat steps 5 and 6 until all lightheads are properly configured.
-
Exit PROGRAMMING by quickly tapping +VDC 3 times to GREEN wire or disconnect all power.
RESETTING
To restore factory setting:
- Apply +VDC to RED, YELLOW, and GREEN wires simultaneously for more than 3 seconds and remove GREEN wire from +VDC to enter FIRMWARE selection.
- Once in FIRMWARE selection mode, momentarily apply GREEN wire to +VDC for more than 3 seconds to reset. All lightheads will blink once to indicate the reset.
- Save and exit by disconnect all power.
Programmable Lighthead Pattern
1| Steady| (All)
2| Single Slow| (Left-Right Split)
3| Single Mid| (Left-Right Split)
4| Single Fast| (Left-Right Split)
5| Double 2Hz| (Left-Right Split)
6| Double| (Left-Right Split)
7| Qoad 2Hz| (Left-Right Split)
8| Ultra| (Left-Right Split)
9| Single-Quad| (Left-Right Split)
10| Single H/L| (Left-Right Split)
11| Random| (All)
12| Off|
13| Single Slow| (All)
14| Single Mid| (All)
15| Single Fast| (All)
16| Double 2Hz| (All)
17| Double| (All)
18| Qoad 2Hz| (All)
19| Ultra| (All)
20| Single-Quad| (All)
21| Single H/L| (All)
Read User Manual Online (PDF format)