cell2 LP26 LED PAD Instructions

June 9, 2024
Cell2

cell2 LP26 LED PAD

cell2-LP26-LED-PAD-PRODUCT

WIRING

cell2-LP26-LED-PAD-FIG-1

  • CAUTION: Ensure that the mounting surface is evenly flat; mounting this light head on non-flat surfaces may result in bending and/or water ingress.
  • NOTE: When using an adhesive mount, ensure that the mounting surface is clean, dry, and well-unified before mounting.

OPERATION

For Flash Patterns:
Momentarily apply +VDC to BROWN wire:

  • once for next pattern
  • quick three times for FP#1

NOTE: This unit may not be factory-set at FP#1.

FP#

|

Flash Pattern

---|---
1| Double| [R65]| 11| Quint                                   [SAE]| 21| Triple| (Split)
2| Single| [2HZ]| 12| Mega| 22| Quad| (Split)
3| Triple| [2HZ]| 13| Giga| 23| Quint| (Split)
4| Quad| [2HZ]| 14| Ultra                                    [SAE]| 24| Mega| (Split)
5| Random| 15| Single-Quad| 25| Giga| (Split)
6| Steady/Cruise| 16| Single H/L| 26| Ultra| (Split)
7| Single| [SAE/CA13]| 17| Single-Triple-Quint| 27| Single-Quad| (Split)
8| Double| [SAE]| 18| Half-Steady-Half-Double (Split)| 28| Single H/L| (Split)
9| Triple| [SAE]| 19| Single                                 (Split)| 29| Single-Triple-Quint (Split)
10| Quad| [SAE]| 20| Double                                (Split)| 30| Steady-Dim EF

  • Actual approval will be based on the model purchased.
  • Split = Top-half alternating Bottom-half.

For Simultaneous or Alternating Synchronization:

  1. Apply +VDC to WHITE and BROWN wires simultaneously to enter Grouping mode; the light head will display short (single or double) flashes:
    • Single flash = Group1
    • Double flash = Group2
  2. Remove BROWN wire from +VDC and momentarily apply to +VDC to change Group:
    • Lightheads in the same Group will flash together.
    • Group1 light heads and Group2 light heads will flash alternatingly.
  3. Save and exit Grouping Mode by disconnecting all power
  4. Connect BROWN wires of multiple light heads together for synchronization; all light heads should be set to the same Flash Pattern.

CAUTION
Overtightening the mounting screws could damage the light head and void the warranty. Use an in-lb torque wrench, and tighten the mounting screws with the suggested range of torque value: For #6 mounting screws – 6 to 7.8 in-lbs.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Cell2 User Manuals

Related Manuals