Cell2 UR06 LED Flush Mount Kit User Manual
- June 9, 2024
- Cell2
Table of Contents
Cell2 UR06 LED Flush Mount Kit
CONTENTS
WIRING & FUNCTIONS
NOTE: Each warning mode may be set to different Flash Pattern & Colour Mode.
OPERATION
For Synchronization:
Connect wires of all lightheads together for synchronization. (All the
lightheads should be set to the same Flash Pattern)
For Warning Colour Mode:
Each Warning Mode may be set to warning or in , . To change Warning Colour
Mode:
- Choose the desired warning mode to change and apply +VDC to its activation wire with wire simultaneously to enter Setting Mode; lighthead will display short flashes in its current Colour Mode.
- Colour 1 (Warning Mode 1 Pre-set)
- Colour 2 (Warning Mode 2 Pre-set)
- Colour 1 alt. 2 (Warning Mode 3 Pre-set)
- Remove wire from +VDC and momentarily apply to +VDC again to change Colour Mode.
- Once in desired Colour Mode, save and Exit Setting Mode by powering off the lighthead.
For Flash Pattern:
While a warning mode is actiaved, momentarily apply +VDC to wire:
-
* once for next pattern
- quick three times to reset to FP#1 (see flash pattern chart)
Flash Pattern
1| Double [2Hz]| 15| Random
2| Single [2Hz]| 16| Double [2Hz] (SPLIT)
3| Triple [2Hz]| 17| Single [2Hz] (SPLIT)
4| Quad [2Hz]| 18| Triple [2Hz] (SPLIT)
5| Single| 19| Quad [2Hz] (SPLIT)
6| Double| 20| Single (SPLIT)
7| Quad| 21| Double (SPLIT)
8| Quint| 22| Quad (SPLIT)
9| Mega| 23| Quint (SPLIT)
10| Ultra| 24| Mega (SPLIT)
11| Single-Quad| 25| Ultra (SPLIT)
12| Single H/L| 26| Single-Quad (SPLIT)
13| Steady EF *| 27| Single H/L (SPLIT)
14| Steady Scene| |
INSTALLATION – FLUSH MOUNT
-
Select a mounting location and drill one 1″ (25.4mm) cut-out.
NOTE: Mounting surface thickness @ 0.8~2.0mm -
From the front, install MOUNTING GROMMET onto the cut-out, and then insert the LIGHTHEAD.
-
Where necessary, apply silicone around the reverse side to prevent from rotating.
-
Where necessary, apply silicone around the reverse side to prevent from rotating.
INSTALLATION – BRACKET MOUNT (sold-separately)
-
From the front, install the MOUNTING GROMMET onto the BRACKET, and insert the LIGHTHEAD.
-
Ensure that triangle mark on the lens is aligned vertically.
-
Secure the LIGHTHEAD onto the BRACKET with a screw.
-
Secure the BRACKET onto the desired mounting surface with screws.
WIRING 2 KITS TOGETHER
Below is a schematic diagram for wiring 2 kits together.
Yellow wires from both controllers must be connected together for
synchronization.
- When Flash Pattern 1~12 is selected: All Heads will flash simultaneously.
- When Flash Pattern 15~26 is selected: Head 1A&2A will flash alternatively with Head 1B&2B.
- refer to Flash Pattern chart on opposite page.
NOTE: To have Head 1A&2B alternate with 1B&2A, simply reverse the lightheaded outlets on one of the Controllers; (both kits must be in Flash Pattern 15~26).
NOTE: The mounting area for controllers varies from vehicle to vehicle.
Read User Manual Online (PDF format)