KLARSTEIN 10029700 Series Air Conditioner Instruction Manual
- June 9, 2024
- Klarstein
Table of Contents
- KLARSTEIN 10029700 Series Air Conditioner
- TECHNICAL DATA
- SAFETY INSTRUCTIONS
- General safety instructions
- Instructions for Handling Damage
- CONTROL PANEL AND KEY FUNCTIONS
- REMOTE CONTROL AND INDICATORS
- Remote control indicators
- General Operation
- INSTALLATION
- CLEANING AND CARE
- TROUBLESHOOTING
- ERROR CODES
- PRODUCT DATA SHEET
- DISPOSAL CONSIDERATIONS
- MANUFACTURER & IMPORTER (UK)
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
KLARSTEIN 10029700 Series Air Conditioner
Dear Customer,
Congratulations on purchasing this device. Please read the following instructions carefully and follow them to prevent possible damage. We assume no liability for damage caused by disregard of the instructions and improper use. Scan the QR code to get access to the latest user manual and more product information.
TECHNICAL DATA
Item number| 10029702, 10029703,
10040152, 10040153
| 10029704, 10029705,
10040154, 10040155
---|---|---
Power supply| 220-240 V ~ 50/60 Hz
Cooling capacity| 7000 BTU| 9000 BTU
Room size| 21-34 m²| 26-44 m²
SAFETY INSTRUCTIONS
Special notes
- Only use agents recommended by the manufacturer for defrosting or cleaning.
- Never store the appliance in a room in which there are permanent sources of ignition (e.g. open flames, a switched-on gas appliance or a switched-on electric heater).
- Do not puncture or burn the appliance.
- Note that coolant may be odourless.
Note: Only use the unit in rooms larger than X m² (see table):
Model | X (m²) |
---|---|
5000 BTU/h, 7000 BTU/h, 8000 BTU/h | 4 m² |
9000 BTU/h, 10000 BTU/h, 10500 BTU/h | 12 m² |
12000 BTU/h, 14000 BTU/h, 16000 BTU/h,18000 BTU/h | 15 m² |
General safety instructions
-
The device is only suitable for indoor use.
-
Do not use the product if it needs to be repaired or if it has not been installed properly.
-
Do not use the product in the following areas:
- near heat sources,
- in areas where oil can splash,
- in areas exposed to direct sunlight,
- in areas where splash water can occur,
- near bathtubs, in washrooms, near showers or swimming pools.
-
Never insert your fingers or other objects into the ventilation openings. In particular, warn children of the dangers this may cause.
-
Ensure that the unit is held vertically during transport and storage so that the compressor is correctly positioned.
-
Always turn off the appliance before cleaning and unplug it from the wall outlet.
-
Switch off the appliance before moving it and unplug it from the wall outlet. Move the appliance slowly and carefully.
-
To avoid the risk of fi re, do not cover the unit.
-
All fan connections must comply with local electrical safety regulations. If necessary, refer to these regulations.
-
Supervise children so that they do not play with the unit.
-
If the power cord is damaged, it must be replaced by the manufacturer, customer service or a similarly qualifi ed person to avoid danger.
-
This equipment may be used by children over the age of 8 and by persons
(including children) with limited physical, sensory or mental capabilities and/
or lack of experience and knowledge, provided they have been instructed in the use of this equipment by a person responsible for their safety and understand the hazards associated with the use of this equipment. Cleaning and maintenance of the appliance may only be carried out by children under supervision. -
The appliance must be installed in accordance with national wiring regulations.
-
Type and voltage of fuses: T, 250 V AC, 2 A or higher.
-
Contact customer service for cleaning and maintenance.
-
Do not pull the power cord, deform or modify it, or immerse it in water. Incorrect handling of the power cord may result in damage to the equipment and/or electric shock.
-
National gas regulations must be observed.
-
Do not block the ventilation openings.
-
Do not operate the appliance solely by inserting or removing the power plug, as this may result in electric shock or fi re due to heat.
-
Immediately unplug the appliance from the wall outlet if it emits strange noises, odours or smoke.
Instructions for Handling Damage
- In case of damage to the device, contact the manufacturer, customer service or a similarly qualifi ed person.
- If damage occurs, turn off the power, unplug the power cord, and contact the manufacturer, the service representative, or a similarly qualifi ed person.
- The power cord must be securely earthed.
- If the power cord is damaged, turn off the power to avoid danger and unplug the power cord from the wall outlet. The power cord must be replaced by the manufacturer, customer service or a similarly qualified person.
WARNING Risk of injury! Repairs to the coolant circuit may only be carried out by trained specialist personnel. Never attempt to repair the unit yourself!
DEVICE OVERVIEW
1 | Control panel | 7 | Ventilation slots |
---|---|---|---|
2 | Ventilation slats | 8 | Air intake |
3 | Vibrating fins | 9 | Connection A |
4 | Rollers | 10 | Exhaust air hose |
5 | Cable holders | 11 | Connections B and C |
6 | Plugs and power cord |
CONTROL PANEL AND KEY FUNCTIONS
- +/- Key
- Temperature display 3 Cooling display
- Drying indicator
- Fan display
- Mode
- Timer
- On / off button
- Sleep mode
- Fan
- Fan speed
+/-| In cooling mode, press these buttons to adjust the temperature in 1 °C
increments. The adjustable temperature range is between 16 °C – 30 °C. This
button is inactive in auto, drying or fan mode.
---|---
MODE| Press this button to select the mode in the following order: Cooling>
Drying> Fan.
COOL: The cooling indicator lights up in this mode. This display shows the set
temperature. The adjustable temperature is between 16 °C and 32 °C.
DRY: The drying indicator lights up in this mode. This display shows no
temperature.
FAN: On this mode only the fan works. The fan indicator lights. The display
shows no temperature.
FAN| Press this button to select the speed in the following order: low >
medium > high > auto > low.
TIMER| Press this button to call up the timer. Then press the +/- key to set
the timer. Each time the button is pressed, the time will change by 0.5 hours
until 10 hours are reached. After that, the value will change by 1 hour each
time you press the button. After you have entered the desired value, wait 5
seconds until the display automatically accepts the time. As soon as the timer
starts running, the timer indicator will light up in the display. If you want
to cancel the timer, press the timer button again in timer mode.
SLEEP| Press this button to activate sleep mode. If the device is currently in
cooling mode, the temperature will increase by 1 °C over the course of one
hour as soon as the sleep mode starts. Over the next 2 hours, the temperature
will rise by a further 2 °C and then will stay at this level. The sleep
function does not work in fan, auto or drying mode.
REMOTE CONTROL AND INDICATORS
1| On / off switch| 8| Fan mode
2| Mode| 9| Temperature
3| ****
+/-
| 10| Timer (automatic switch-on or switch-off)
4| Fan| 11| Turbo
5| Panning movement (up / down)| 12| Sleep mode
6| Swiveling movement (left / right)| 13| Light
7| Health mode / Save| |
Remote control indicators
Notes:
- This is a universal remote control for air conditioning systems with multiple functions. If you press a button with functions that the device does not have, the device will remain in its current state.
- After the device is connected, the air conditioner will emit a sound, and the operating light will light up red. You may now operate the device using the remote control.
- If the device is switched on, the transmit symbol WIFI on the remote control will flash once after each key press.
- When the device is switched off, the set temperature will appear on the remote control. When switched on, the remote control display will show the symbol for starting up.
On / off switch (ON / OFF) Press to turn the device on or off. After
startup will light up green. (The color of the display differs from model to
model).
Mode Press to go through and select the modes.
AUTO| In automatic mode, the air conditioner will run automatically depending
on the ambient temperature. The set temperature cannot be changed and is also
not displayed. Press the FAN button to set the fan level. and press to adjust
the pan movement. Press and to adjust the swivel movement.
---|---
COOL| When you select cooling mode, the air conditioner will run in cooling
mode. The symbol will appear on the display. You can press the [+] and [-]
buttons to set the temperature. Press the FAN button to set the fan level.
Press and to adjust the swivel movement.
DRY| The fan will run at a low speed in dehumidification mode. You cannot
change the fan level in dehumidification mode. The symbol appears on the
display. Press and to adjust the swivel movement.
FAN| The device will only run in ventilation mode. All function symbols in the
display have gone out. The operating indicator will light up. With the FAN
button, you can set the fan speed. Press and to adjust the swivel movement.
HEAT| The device will heat in this mode. The symbol appears on the display.
Use the [+] and [-] buttons to set the temperature. Press and to adjust the
swivel movement. (Devices with exclusive cooling do not receive a signal when
you press the HEAT button.)
Note: To avoid a cold wind after starting, the indoor fan will start blowing with a delay of 1-5 minutes. The exact time is determined by the room temperature. The range of the adjustable temperature is between 16 ° C and 30 ° C. Possible fan levels: auto, low, medium, and high.
+/- Keys Temperature setting: If you press [+] or [-], the set
temperature will be increased or decreased by 1 ° C (or 1 ° F). Hold the
button down. After 2 seconds, the set time on the remote control will change.
Release the button after the desired time value has been reached. The display
will change accordingly. The temperature cannot be set in auto mode.
Timer on/off or setting the time: press +/- to set the time (see TIMER).
FAN Press sets the fan speed in these steps: automatic, low, medium, and
high.
Note: In automatic mode, the fan automatically adjusts the level depending on the ambient temperature. In dehumidification mode, the fan runs at a low temperature.
Swivel movement up / down The settings appear in the following order: if you press on the remote control, the pan movement is automatically set. The horizontal slats in the air conditioning system automatically move up and down at the greatest possible angle.
When you select the remote control, you set a fixed pan position. The horizontal slats will stop in the position indicated in the symbol.
Swivel movement left / right The settings appear in the following order: if you press on the remote control, the pan movement is automatically set. The vertical slats in the air conditioning system automatically move up and down at the greatest possible angle.
When you press on the remote control, the pan movement is automatically set. The horizontal slats in the air conditioning system automatically move up and down at the greatest possible angle.
When you select the remote control, you set a fixed pan position. The horizontal slats stop in the position indicated in the symbol.
HEALTH/SAVE
Health function: after pressing the HEALTH button, the setting of the remote
control changes in this order: HEALTH > AIR > AIR > HEALTH > No display. When
the respective symbol is selected with the remote control, the corresponding
mode will start.
SAVE function: if you press the Save button in cooling mode, the device will
run in SAVE mode. ‘SE’ will appear on the remote control display. The device
will run in automatic mode, the temperature cannot be set. Press SAVE again to
exit this mode and the device will return to its original set level and
temperature. Note: This function is only available on some models.
Fan operation / X fan After pressing this button in cooling mode and in
dehumidification mode, the display will show and the fan will continue to run
for 2 minutes to dry the device. After switching on the device, the
ventilation mode will be automatically activated. This function is not
available in automatic mode, ventilation mode and heating mode. If you switch
off the device again after activating this function, the fan will run at a low
level to dry condensation in the device.
TEMP / Temperature setting Press this button to show the set temperature, indoor temperature or outdoor temperature on the display.
- Selection of the remote control: the display of the set temperature.
- Selection of the remote control: the display of the internal temperature.
- Selection of the remote control: the display of the outside temperature.
Note: On some models, the outside temperature cannot be displayed. Display only for models with a two-digit display.
TIMER / automatic timer
Automatic switch-off: when the device is switched on: press this button to set the automatic switch-off. ‘HOUR’ and ‘OFF’ will flash on the display. Press the [+] and [-] buttons within 5 seconds to set the time for the shutdown. Pressing [+] and [-] increases or decreases the time by 1/2 hour. If you hold down [+] and [-] for 2 seconds, the time value changes quickly. Then press TIMER to confirm. ‘T-OFF’ and ‘H’ will no longer flash.
Automatic switch-on: when the device is switched off: press this button to set the automatic switch-on. ‘T-OFF’ and ‘H’ will flash on the display. Press the [+] and [-] buttons within 5 seconds to set the time for switching on. Pressing [+] and [-] increases or decreases the time by 1/2 hour. If you hold down [+] or [-] for 2 seconds, the time value changes quickly. Then press TIMER to confirm.
Note: The setting range is 0.5-24 hours. The time interval between two entries must not exceed 5 seconds, otherwise, the remote control will leave the input mode.
TURBO When this button is pressed in cooling or heating mode, the air
conditioner will go into quick cooling mode or quick heating mode. ‘TURBO’
will appear on the remote control display. Press the button again to exit
turbo mode. The ‘TURBO’ display will go out.
SLEEP When this button is pressed in cooling or heating mode, the air
conditioner will go into sleep mode. The symbol will appear on the remote
control display. Press the button again to exit sleep mode. The sleep symbol
will disappear.
Light This button turns off the remote control indicator light. The
Light symbol is hidden. Press the button again to turn the light back on.
The Light symbol will reappear.
Child safety Press [+] and [-] at the same time to switch on the childproof lock. When the child lock is activated, the display appears on the remote control. If you now press any buttons, will flash three times and the remote control will not send any signal.
General Operation
- After connecting to the power supply, press the ON / OFF button on the remote control to switch on the device.
- Press MODE to select the desired operating mode: AUTO, COOL, DRY, FAN, HEAT.
- Press [+] and [-] to set the desired temperature. The temperature cannot be set in AUTO mode.
- Press FAN to set the desired fan level: AUTO, LOW (low), MEDIUM (medium), and HIGH (high).
- Press and select the pan movement.
Replacement of the remote control batteries
- Press the retaining clip on the battery compartment of the remote control and slide off the cover in the direction of the arrow.
- Replace the old batteries with two LR03 batteries. Make sure that the polarity is correct.
- Put the battery cover back on.
Note: The distance between the signal generator and the signal receiver must not be more than 8 metres.
- If the signal in the room is disturbed by fluorescent lights, neon lamps or mobile phones, move the remote control closer to the device.
- Replace the batteries with the same type.
- Remove the batteries if you will not be using the remote control for a long time.
- If the display on the remote control becomes blurred or shows nothing, replace the batteries.
INSTALLATION
Accessory
Additionally, you need a cross screwdriver, a straight screwdriver, a saw, a gauge, a scissor, and a pencil.
Installing the Wire Hook
- Assemble the wire hook at the back of the unit with screws (the direction of wire hook is as shown in the following fig.
- Wind the power cord around the wire hook.
Installing the Heat Discharge Pipe
- Rotate joint A and joint B clockwise into the two ends of heat discharge pipe.
- Insert joint A of heat discharge pipe (the side with „TOP“ is upwards) into the groove until you hear a sound.
- Aim the locating pole of joint B of heat discharge pipe at the opening of joint C; rotate it slightly to make joint B and joint C connect tightly.
- in order to improove cooling efficiency, the heat discharge pipe should be as short as possible and flat without curve to ensure smooth heat discharge.
- Correct installation is as shown in figure. When installing it on a wall, height of hall should be about 40 cm – 130 cm from floor.
- If the pipe is bent too much, it would easily cause malfunctions.
Manual Removement of collected Water When using the continuous drainage option from the bottom hole, install drainage pipe before using, other- wise poor drainage will affect normal operation of the unit. Remove the rubber plug at drainage port. Fix the drainage pipe clip on the right of rear side plate near drainage port with a screw.
Put the drainage pipe into the drainage port and screw it up, and then bind it with a pipe hoop. Put the rubber plug into the other side of the drainage pipe, fix it with a pipe hook, and then fix it in the drainage pipe clip.
Drainage way as follows In cooling or drying operation, the condensation water will be drained to the chassis and spattered by water- striking motor. As the temperature of the condenser is high, most of the condensation water will be evaporated and drained to outdoors. So usually, only a little condensation water will be accumulated inside the chassis and you do not need to discharge the water frequently. When the chassis is full with water, the buzzer will give out 8 sounds and „H8“ is displayed to remind user to discharge water.
- Move the unit to a suitable place for discharging water; do not tilt the unit and keep it horizontal during moving;
- Take the drainage pipe from the clip and pull out the rubber plug on the drainage pipe to discharge water;
- After full water protection is eliminated and the compressor has been stopped for 3 minutes, the unit will resume operation.
Using a continuous Drainage The water can be discharged automatically via the central outlet. You will need the supplied rubber hose, hose adapter and hose clamp.
This is how you set up the drain:
Important Hint on using a continuous Drainage When using the continuous drainage option from the middle hole, place the portable on a level surface and make sure garden hose is clear of any obstructions and is directed downward. Placing portable on an uneven surface or improper hose installation may result in water filling up the chassis and causing the unit to shut off. Empty water in the chassis if shut off occurs, then check portable location and hose for proper setup.
CLEANING AND CARE
Before cleaning the air conditioner, please turn off the unit and disconnect power. Otherwise, it may cause electric shock. Do not wash air conditioner with water. Otherwise, it may cause electric shock. Do not use volatile liquid (such as thinner or gas) to clean the air conditioner. Otherwise, it may damage the appearance of air conditioner.
Clean outer Case and Grille Clean outer case: If there‘s dust on the surface of an outer case, please use soft towel to wipe it. If the outer case is very dirty (such as grease), please use neutral abluent to wipe it. Clean grille: Use a cleaner or soft brush to clean it.
Clean Filter
- Remove filter.
- Use clean water to clean the filter. If the filter is very dirty (such as grease), use warm water 40 °C (104 °F) melted with neutral abluent to clean it and then put at shady place to dry it.
- After the filter is cleaned and completely dried, reinstall it well.
Cleaning the Heat Discharge Pipe Remove the heat discharge pipe from air conditioner, clean and dry it , and then reinstall it. (For the method of installation and removal , please refer to the instruction for „Installation and disassembly of heat discharge pipe“).
Checking before Use-Season
- Check whether air inlets and air outlets are blocked.
- Check whether plug and socket are in good condition.
- Check whether filter is clean.
- Check whether batteries are installed in remote controller.
- Check whether joint, window bracket and heat discharge pipe are installed tightly.
- Check whether heat discharge pipe is damaged.
Checking after Use Season
- Disconnect power supply. Clean filter and outer case.
- Remove dust and sundries on the air conditioner.
- Eliminate accumulated water in chassis (refer to the section of „Drainage way“ for details).
- Check whether window bracket is damaged or not. If yes, please contact the dealer.
Long-time Storage If you don‘t use the air conditioner for a long time, make sure there‘s no accumulated water in chassis. Pull out the plug and wrap the power cord. Clean the air conditioner and pack it well to prevent dust.
TROUBLESHOOTING
Problem | Possible Cause | Solution |
---|---|---|
Air conditioner can‘t operate. | Is plug loose? | Reinsert the plug. |
Whether the unit is restarted up after stopping immediately. | Wait for 3min, |
and then
turn it on again.
Poor cooling.| The air filter is too dirty.| Clean the air filter.
The set temperature is proper.| Adjust the temperature.
Door and window are not closed.| Close dorrs and windows.
Air conditioner can‘t receive signal from remote contr- oller or remote
controller is not sensible.| Remote controller is not within the receiving
range.| The receiving range of remote controller is 8 m. Do not exceed this
range.
Whether it‘s blocked by obstacles.| Remove the obstacles.
Is sensitivity of remote controller low.| Check the batteries of remote
controller. If the power is low, please replace the batteries.
There’s a fluorescence
lamp in the room.
| Move the remote controller close to air conditioner or turn off the
fluorescence lamp and try it again.
No fan blowed out from air conditioner.| Air outlet or air inlet is blocked.|
Eliminate the obstacles.
Set temperature can‘t be adjusted.| The unit operates under auto mode.|
Temperature can‘t be adjusted under auto mode.
The required temperature exceeds the temperature setting range.| Temperature
setting range: 16°C-30°C .
There‘s abnormal sound during operation.| The unit is interfered by thunder,
radio, etc.| Disconnect power, put thro- ugh the power again, and then turn on
the unit again.
ERROR CODES
H8
| ****
Chassis is full of water.
| Pour out the water inside chassis. If „H8“ still exits, please contact
professional person to maintain the unit.
---|---|---
F1
| Malfunction of ambient temperature sensor.| ****
Please contact professional person to deal with it.
F2
| Malfunction of evaporator
temperature sensor.
| ****
Please contact professional person to deal with it.
F0
| ****
Refrigerant is leaking or system is blocked.
| Re-energize the unit after turning off and pulling out the plug for 30 min; If there‘s still malfunction, please contact after- sales service.
H3
| ****
Overload protection for compressor.
| Check if the unit is under high-temperature and high- humidity environment; if ambient temperature is too high, power off the unit and then energize it for operation after the ambient temperature drops to 35 °C below
E8
| Overload malfunction.| Check if the evaporator and condenser are blocked by
some objects; if yes, take away the objects, power off the unit and then
energize it for operation. If the malfunction still occur, please contact our
after-sales service center.
F4| Outdoor tube temperature sensor is open/short-circuited.| Please contact
professional person to deal with it.
NOTES ON REFRIGERANT R290
Warnings
- The air conditioning system must be kept and transported upright. Otherwise, irreparable compressor damage may Leave the unit for at least 24 hours before putting it into operation.
- Switch off the device and disconnect it from the power supply before
- Make sure that the product creates a steady stream of Ensure the air inlets and outlets are not blocked.
- To prevent leaks, operate this unit on a horizontal
- Any person performing work on a refrigerant circuit should have a current certificate from an industry-accredited assessment body. This ensures competence for the safe handling of refrigerants according to an industry-recognized assessment
- If the device stops working, dispose of it
- Store the device in a well-ventilated place when not in
- Store the device so that it is not
- Repairs may only be carried out by the manufacturer or an authorized specialist
- Do not damage any components of the refrigerant Escaping refrigerant may not be noticed because it is odorless.
- Maintenance and repairs must be carried out under the supervision of specialists in the use of flammable refrigerants.
Information for rooms with refrigerant pipes
- Limit the piping to a minimum.
- Be careful not to damage the piping.
- Appliances with fl ammable refrigerants may only be installed in a well-ventilated room.
- Comply with national gas regulations.
- All mechanical connections must be freely accessible for maintenance purposes.
CAUTION Risk of fire! This device contains the flammable refrigerant R290. If the refrigerant escapes and is exposed to an external ignition source, there is a risk of fire.
PRODUCT DATA SHEET
- Supplier‘s trademark: Klarstein
Supplier‘s model identifier: 10029702, 10029703, 10040152, 10040153
Inside sound power levels at standard rating conditions on cooling mode in dB: 63 dB
Refrigerant (R290) leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 3. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 3 times higher than 1 kg of CO2 , over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
- Energy efficiency ratio (EERrated): 2,6
- Energy efficiency class: A
Energy consumption 0,8 kWh per 60 minutes, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
- Cooling capacity Prated in kW: 2,1 kW
Information according to regulation (EU) No. 206/2012
Model identifier(s)| 10029702, 10029703,
10040152, 10040153
---|---
Description| Symbol| Value| Unit
Rated capacity for cooling| Prated for cooling| 2,1| kW
Rated capacity for heating| Prated for heating| –| kW
Rated power input for cooling| PEER| 0,8| kW
Rated power input for heating| PCOP| –| kW
Rated Energy efficiency ratio| EERd| 2,6| –
Rated Coefficient of performance| COPd| –| –
Power consumption in thermostat-off mode| PTO| 109| W
Power consumption in standby mode| PSB| 0,3| W
Electricity consumption of single/double
duct appliances
(indicate for cooling and heating separately)
| DD: QDD SD: QSD|
0,8
| DD: kWh/a SD: kWh/h
Sound power level| L WA| 63| dB(A)
Global warming potential| GWP| 3| kgCO2 eq.
Contact details
for obtaining more information
| Chal-Tec GmbH,
Wallstraße 16, 10179 Berlin, Germany.
DISPOSAL CONSIDERATIONS
If there is a legal regulation for the disposal of electrical and electronic devices in your country, this symbol on the product or on the packaging indicates that this product must not be disposed of with household waste. Instead, it must be taken to a collection point for the recycling of electrical and electronic equipment. By disposing of it in accordance with the rules, you are protecting the environment and the health of your fellow human beings from negative consequences. For information about the recycling and disposal of this product, please contact your local authority or your household waste disposal service.
This product contains batteries. If there is a legal regulation for the disposal of batteries in your country, the batteries must not be disposed of with household waste. Find out about local regulations for disposing of batteries. By disposing of them in accordance with the rules, you are protecting the environment and the health of your fellow human beings from negative consequences.
MANUFACTURER & IMPORTER (UK)
Manufacturer:
- Chal-Tec GmbH, Wallstrasse 16, 10179 Berlin, Germany.
Importer for Great Britain:
- Chal-Tec UK Limited
- Unit 6 Riverside Business Centre
- Brighton Road
- Shoreham-by-Sea
- BN43 6RE
- United Kingdom
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>