Honeywell TP50WKN 50Pint Energy Star Dehumidifier User Manual
- June 9, 2024
- Honeywell
Table of Contents
TP50WKN 50Pint Energy Star Dehumidifier
User Manual Model
TP-SMALL/ TP-BI
THANK YOU
Thank you for purchasing a Honeywell Dehumidifier. This User Manual is
intended to provide you with important information needed to set up, operate,
maintain and troubleshoot this product.
SAFETY RULES
WARNING — READ AND SAVE THESE INSTRUCTIONS BEFORE USING THIS PRODUCT.
The use of electrical products may create hazards that include, but are not
limited to injury, fire, electrical shock. Failure to follow these
instructions may damage and/ or impair its operation and void the warranty. In
case there is any inconsistency or conflict between the English version and
any other language version of the content of this material, the English
version shall prevail.
When using electrical appliances, basic safety precautions should always be
followed:
- DO NOT touch the dehumidifier or the electrical plug with wet hands.
- Check the household voltage to ensure it matches the appliance’s specification.
- Before operating, remove all packaging material and check for any damage that may have occurred during shipping.
- DO NOT operate any product with a damaged cord or plug.
- DO NOT use an extension cord with this appliance.
- DO NOT run power cord under carpeting, or cover it with rugs or runners. Keep the cord away from areas where it may be tripped over.
- Always unplug the dehumidifier before emptying the water tank.
- The water collected in the tank must be discarded. The water should never be used for drinking.
- Always unplug the dehumidifier and remove the water from the water tank before cleaning, servicing or relocating the unit.
- Remove the power cord from the electrical receptacle by grasping and pulling on the power cord plug-end only, never pull the cord.
- This appliance has been manufactured for use in domestic environments and must not be used for other purposes.
- DO NOT use the product in areas where gasoline, paint or other flammable goods and objects are used or stored.
- This dehumidifier is designed for indoor residential applications only. It should not be used for commercial or industrial applications.
- DO NOT attempt to repair or adjust any electrical or mechanical functions of the dehumidifier, as this may cause danger and void the warranty.
- DO NOT cover the air inlet or outlet on the appliance as this may cause the unit to fail.
- DO NOT insert or allow objects to enter any ventilation or exhaust opening as this may damage the product and could cause electrical shock or fire.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- DO NOT let children play with this appliance, packaging or included plastic bag.
- If the unit is damaged or it malfunctions, do not continue to operate it. Unplug the product from the electrical outlet. Refer to the troubleshooting section and contact the customer support center.
- Always place the dehumidifier on a leveled floor.
- Never install the product near a bathtub or any water container.
- Store in a dry area, away from direct sunlight, when not in use.
- This appliance and its packaging materials are not intended for use by persons (including children or elderly) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instructions concerning the use of the appliance by a person responsible for their safety.
- Always grip the top handle and keep the unit upright when transporting from room to room — DO NOT tilt the product on its side or upside-down.
- If the dehumidifier was transported tilted on its side, you must position it upright again and wait at least 4 hours before using it.
- WARNING: To reduce the risk of fire or electric shock, do not use this appliance with any solid state speed control device.
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.
REGULATION STATEMENT
TP-BIG and TP-SMALL – R290
SYMBOL | NOTE | EXPLANATION |
---|---|---|
WARNING | This symbol shows that this appliance uses a flammable |
refrigerant. If the refrigerant is leaked and exposed to an external ignition
source, there is a risk of fire.
| CAUTION| This symbol shows that the operation manual should be read
carefully.
| CAUTION| This symbol shows that a service personnel should be handling this
equipment with reference to the installation manual.
****| CAUTION| This symbol shows that information is available such as the
operating manual or installation manual.
Additional warnings for appliances with R290 refrigerant gas.
- Read the instruction carefully before using the appliance.
- When defrosting or cleaning, do not use any method other than those recommended by the manufacturer.
- Do not place the appliance in a room with continuous sources of ignition (e.g. open flame, operating gas appliance or working electrical heater).
- Do not pierce and do not burn.
- Do not perforate any part of the refrigerant circuit.
- Refrigerant gas may be odorless.
- The appliance must be installed, used and stored in an area that is greater than 13m’.
- Accumulation of possible refrigerant leaks in an unventilated room could lead to fire or explosion should the refrigerant come in contact with electric heaters, stoves or other sources of ignition.
- The appliance must be stored in a way to prevent mechanical damage.
- Only individuals authorized by an accredited organization certifying their competence to handle refrigerants in compliance with industry legislation should work on the refrigerant circuit.
- R290 refrigerant gas complies with European environmental directives.
- This appliance contains a certain number of grams (see rating label at the back of the unit) o f R290 refrigerant gas. The maximum refrigerant charge amount is 0.05 kg.
**** Repair must be performed based on the recommendations from the manufacturer. Maintenance and repair that requires the assistance of other qualified personnel must be performed under the supervision of specialists in the use of flammable refrigerants.
HOW A DEHUMIDIFIER WORKS
When the dehumidifier is switched ON, a fan pulls moisture-laden air into the
dehumidifier where it passes through dehumidifying coils inside the unit.
These coils condense moisture from the air and collect it in the water tank.
The dry air is then exhausted from the dehumidifier. The air flows through the
air vents of the dehumidifier into the room as dry, warm air.
IMPORTANT: The dehumidifier is designed to operate between 41°F (5°C) and
89°F (32°C). The dehumidifier’s performance may be greatly reduced if room
temperature is beyond this temperature range.
SELECTING A LOCATION – IMPORTANT
-
Before using the dehumidifier, place the unit UPRIGHT for at least 1 hour before use to allow the refrigerant to stabilize. If the unit was tilted on its side or upside-down during transportation, set the unit upright for 4 hours before use.
-
For optimal efficiency, the dehumidifier must be operated in an enclosed area. Keep all doors, windows and other outside entrances to the room closed.
-
Place the dehumidifier in an area where the temperature will not drop below 41°F (5°C)
-
Place the dehumidifier a t least 17.7 inches (45 cm) away from other objects (e.g. curtains or furniture) that may restrict airflow from the back or through the air vents of the unit.
-
The dehumidifier must be positioned on a level floor.
IMPORTANT: The effectiveness of the dehumidifier can be influenced by different factors. One factor is the rate at which new, moisture-laden air enters the room and the amount of air circulating in and out of the area to be dehumidified. For example, if a door to a basement i s constantly opened, letting new, moisture-laden air into the room, dehumidification will take longer than if the door was kept closed. If the dehumidifier is in a room with a storage closet or cabinets, it will have little or no effect in drying the inside of the storage closet or cabinets unless there is adequate circulation of air in and out of these spaces. To dehumidify these spaces, open the storage door or cabinet doors to allow air circulation. You may find that installing a second dehumidifier may be required for larger enclosed areas.
UNPACKAGING THE DEHUMIDIFIER
This Dehumidifier is packaged with a colored or transparent tape to secure some parts during transportation. Remove the colored or transparent packaging tape from the unit.
-
Gently pull the water tank from out of the dehumidifier
-
Remove the splash guard from the top part of the water tank
-
Take out the power plug, drain hose and other accessories, which is placed inside the tank of the dehumidifier.
-
Once all accessories have been removed, replace the splash guard onto the top part of the water tank. Make sure that the tank is properly positioned.
There is a Foam Float inside the water tank that senses the water level to
automatically stop dehumidification when the water tank is full. Make sure the
Foam Float is positioned correctly inside the water tank by ensuring it lies
level with the top edge of the water tank.
DO NOT REMOVE THIS FOAM FLOAT.
PARTS DESCRIPTION
1)Control Panel
2)Handle
3)LED Display
4)Splash Guard
5 )Water Tank Handle
6 )Foam Float
7) Water Tank
8 )Water Level Indicator
9 ) Casters| 10) Dehumidified Air Exhaust Vent
11) Washable Dust Filter
12) Direct Drain Outlet
13) Direct Drain Cap
14) Mounting Holes for Cord Winders
15) Power Cord & Plug
16) Cord Winders
17) Continuous Water Drain Tube
18)Continuous Water Drain Cap
---|---
INSTALL THE CORD WINDER
Once you have removed the cord winder accessories from the water tank – follow
the steps below.
Step 1 : Line up the cord winder pieces to the mounting holes. Step 2: Rotate
45-degrees clock-wise.
Step 3: Once you hear “click”, then you know the cord winder is ready for
use. NOTE: Once the installation of the cord winder has been completed.
The cord winder cannot be removed. The installation is permanent.
USE & OPERATION
CONTROL PANEL
- Display Screen
- Power Control
- Humidity / Timer Set Controls
- Fan Speed Control
- Timer Control
- Filter Alert
- Sleep Mode
- Water Full Indicator Light
- Continuous Operation Light
FUNCTION BUTTONS
POWER CONTROL
Press to switch the dehumidifier ON or OFF.
HUMIDITY CONTROL SETTING
When the unit is switched ON, the Display Screen shows the current humidity
percentage.
Press + or – m to select your preferred humidity level. The humidity is
adjusted in increments of 5% by pressing + or – mm. The adjustable Relative
Humidity (RH) range is between 30% RH to 90% RH. Ten seconds after setting the
preferred humidity setting, the display will revert back to displaying the
current humidity.
Recommended Settings: It is recommended to leave the unit running at 30%
humidity at High Fan Speed during the first 2 to 3 days until damp odors are
removed. After a few days when the Relative Humidity has been reduced to a
more comfortable level, press 4 or == to choose a higher RH% that maintains a
comfortable humidity level thereafter. A recommended healthy humidity level is
between 40% and 50%.
NOTE: The humidity sensor senses current humidity in the surrounding
area. It is normal for a few degrees of variance to the humidity sensitivity
from the sensor.
CONTINUOUS MODE
To activate the Continuous Mode, press the – button on the Display Screen
until appears.
The indicator light will be illuminated. The unit will run continuously.
WATER TANK FULL ALERT
When the Water Tank is full, the indicator will be illuminated. The unit will
beep for 3 seconds. The compressor will shut off, and the fan will stop for a
few minutes. To switch off the indicator light, empty the water tank and when
replacing it ensure the tank is secured properly in place.
IMPORTANT: Do not place the Water Tank on the floor when full. In case o
f an uneven base which may cause the tank to spillover.
TIMER CONTROL
The dehumidifier can be set to automatically switch ON or OFF for a selected
period of time (between 0.5-24 hour intervals). The Timer hours selection is
displayed on the Display Screen.
NOTE: Before setting the Timer control, make sure there is power t o the
unit.
Auto-Off Timer:
While the unit is running, press , the timer indicator light will flash, press
- or -to select the number of hours (0.5-24 hours) you want the unit to run
before it switches off. In 5 seconds without the operation, the Timer start
function, the timer indicator light is illuminated. Timer must be set again
after each use.
Auto-On Timer:
When unit is in Standby Mode, press , the timer indicator light will flash, press + or – to select the number of hours (0.5-24 hours) until you want the unit to automatically start running. In 5 seconds without the operation, the Timer start function, the timer indicator light is illuminated. The previous fan speed and humidity setting will be maintained. The unit will turn on and continue running until the water tank is full (unless the unit is set up for continuous draining) or until you switch it off manually. Timer must be set again after each use.
NOTE: To cancel any Timer settings, simply press again, and the timer indicator light will disappear.
NOTE: The solid red Power light indicates the unit is on Standby Mode.
FAN SPEED CONTROL
There are two fan speeds – High and Low. When, the indicator light is illuminated, the unit is operating on High speed. When the indicator light is off, and the unit is on the unit is operating on Low speed.
FILTER ALERT
When the Filter Alert Light is ON, it is time to clean the filter. Switch the u n i t OFF and carefully remove the filter from the unit and clean. Replace the filter and switch ON the unit.
The Filter Alert Light should not be illuminated until the filter requires cleaning again. The frequency of filter cleaning depends on room environment conditions. Some rooms may require changing more frequently than others.
SLEEP MODE
The LED display brightness will be reduced when the unit is in Sleep Mode.
Press the to activate the Sleep Mode. When Sleep Mode is activated the
indicator light will be illuminated. There is a one-minute window period in
which you can adjust the settings such as humidity and fan speed. After one
minute has lapsed, the top display will shut off, except the indicator light.
Press any button to deactivate Sleep Mode.
AUTO RESTART FUNCTION
This unit is equipped with an Auto Restart feature. When there is a power
outage, the dehumidifier will automatically resume all its previous settings
upon regaining power.
AUTOMATIC DEFROST
Frost may build up on the internal coils of the unit. When there is frost
build up, the internal compressor will turn off and the fan will continue to
run until the frost has melted. Once the internal coils have defrosted and
dried, the compressor or fan will automatically restart and dehumidifying will
resume.
DRAINING THE WATER
WARNING: Always drain and discard water collected from
dehumidification.
The water is not clean and cannot be used for drinking.
1. Draining water collected in the Water Tank
The condensed water can be collected directly into the water tank. When the
water tank is full, the dehumidifier will automatically shut OFF and the
**indicator will illuminate on the control panel followed by a beeping
sound.
IMPORTANT: Do not move the dehumidifier wnen the Water Tank is full as it
will be heavy and can cause water Spillage.
1.1 Locate the water tank at the front of the dehumidifier. Gently pull the
water tank out.
1.2 Grip the handle inside the water tank and carry the water tank to a sink
to empty.
1.3 Replace the empty water tank back into the front of the dehumidifier.
Please make sure that the tank is properly positioned. The safety feature
ensures that any misalignment of the tank and the unit will prevent the unit
from turning back on.
IMPORTANT: Improper alignment or positioning of the water tank will cause
the unit to pause operation, the warning light on top of the dehumidifier will
illuminate followed by a beeping sound, until the water tank is fitted
properly.
NOTE: There is a Foam Float inside the water tank that senses the water
level to automatically stop dehumidification when the water tank is full. Make
sure the Foam Float is positioned correctly inside the water tank by ensuring
it lies level with the top edge of the water tank.
DO NOT REMOVE THIS FOAM FLOAT.
2 . Continuous Water Drainage — Using a Continuous Water Drain Tube
A continuous water drainage tube is included with this unit. To activate the
continuous water draining function, you will require a suitable water drain
(e.g. sink or drain hole at floor level) near the dehumidifier. NOTE: The Continuous Drain Tube and Continuous Drain Cap come
pre-installed.
2.1 Locate the drain outlet at the back of the unit. Unscrew and remove the
Direct Drain Cap. Insert and screw the Continuous Water Drain Tube into the
Direct Drain Outlet. 2.2 If there are leaks, the Continuous
Water Drain Tube and Cap may have loosened and may not be connected properly.
Disconnect, replace and tighten again. 2.3 Position the other end of the
Continuous Water Drain Tube in the sinkor drain. Make sure the tube is not
bent or kinked which might stop the water flow. Make sure the tube is secured
over the drain and will not fall out of place causing unwanted water spillage.
IMPORTANT: Make sure water can flow
down the Continuous Water Drain Tube by keeping the tube angled down and free
of bends or kinks.
IMPORTANT:** If the unit is placed on uneven ground, or the Drain Tube is
installed incorrectly, the water may fill the water tank and stop running.
Please check whether the ground is uneven and reinstall the Drain Tube.
CLEANING & MAINTENANCE
WARNING: Always switch OFF the dehumidifier and unplug it from the
electrical outlet before attempting any cleaning or maintenance of this
product.
Appliance Maintenance:
- Switch OFF the appliance before disconnecting the power supply.
- Only use a soft cloth to clean the appliance.
Dust Filter Maintenance:
The Dust Filter located at the back of the unit helps to remove dust particles
from the air. A dirty filter clogged by dust particles can reduce the
efficiency of the dehumidifier. For optimum dehumidification, it is
recommended to clean the dust filter every 2 weeks:
- Switch off and unplug the dehumidifier from the electrical outlet.
- Carefully pull out the dust filter from the dehumidifier.
- Rinse the dust filter under running water, or vacuum away the dust with a vacuum cleaner.
- After cleaning the dust filter, dry in a cool, shaded place, then carefully reinstall into the unit.
End of Season Storage & Maintenance:
If the appliance will not be used for an extended period of time:
- Switch OFF the unit and unplug from the electrical power outlet.
- Empty the water tank and let it dry. If your dehumidifier is connected to the continuous drain hose, you must disconnect the hose, dry and then replace the drain cap back into the drain outlet.
- Remove the air filter and clean with water. Let the air filter dry and reinstall back into the unit.
- Make sure all parts of the dehumidifier and accessories are dry before storage.
- Cover the dehumidifier with a cloth/ plastic bag before storage, t o protect the surface from dust and scratches.
- It is recommended to coil the power cord and store it off the floor to ensure it is protected from bends and kinks.
- Store the unit upright in a dry location, away from direct sunlight.
TROUBLESHOOTING GUIDE
The following troubleshooting guide addresses the most common problems. If problems persist, call customer service.
PROBLEM | POSSIBLE CAUSE | SOLUTION |
---|---|---|
Dehumidifier does not start | No electricity. | Check for power. |
The power cord Is not properly plugged in. | Remove and reconnect the power |
cord.
The safety switch activated on the electrical plug.| Reset the safety switch
and wait for 3 minutes to pass. Contact customer service if problem persists.
The water tank is not in the correct position.| Position the water tank
correctly into the unit. Unit will not operate until the water tank is secure
in place.
Unit runs but the humidity level does not decrease| The humidity level setting
is too high.| Decrease the humidity level setting.
A door or window is open, letting in new moisture.| Make sure all windows or
doors to the outside are closed and tightly sealed.
There are other sources of humidity in the room (e.g. boiling water in pot).|
Switch on the dehumidifier when these sources are not present.
The temperature in the room is too low.| The dehumidifier is designed to
operate between 41°F (5°C) and 89°F (32°C). Moisture removal is greatly
reduced if room temperatures exceed this temperature range.
The dust filter is dirty/ blocked.| Clean the dust filter.
Air outlet or intake is blocked.| Remove blockage.
Unit runs but the humidity level does not decrease| Insufficient time for the
dehumidifier to remove moisture.| After Initial installation, allow 24 hours
to maintain desired dryness.
---|---|---
Dehumidifier runs constantly/ does not stop| Area to be dehumidified is too
large.| The capacity of your dehumidifier may not be adequate for the room it
Is used In. It is recommended to add an extra dehumidifier for large areas.
A door or window Is open. letting in new moisture.| Make sure all windows or
doors to the outside are closed and tightly sealed.
Water Tank Full **** is illuminated and the unit is beeping| The water tank is
full.| Empty the water tank.
The water tank is not in the correct position.| Position the water tank
correctly Into the unit Unit will not operate until the water tank is secure
in place.
The unit is blowing cold air out of the top vent| The purpose of the top air
vent is to distribute air into the room.| The temperature of the air from the
vent depends on the room environment and other factors. It can fluctuate and
this is normal. No action required.
Frost appears on the coils| Dehumidifier has been recently turned on in low
room temperatures (usually below 41°F
(5°C)).| This is normal. Frost will disappear in an hour or so after the
dehumidifier is switched OFF.
Connected the continuous drain but the water condensation is not draining
out the tube| Some floors may have an uneven surface which may affect the
continuous drainage function| Raise the front of the Dehumidifier 1/2 to 1
inch (1.27 cm to 2.54 cm) from the floor. The water condensation will drain
out the back hose and not into the bucket.
Water on the floor| The garden hose/ drain hose may be loose.| Check the
connections between the hose and the drain outlet on the unit. See Continuous
Water Drainage section.
You intended to use tne but the continuous drain hose is still connected|
Disconnect the hose and replace the rubber stopper and drain cap if using the
water tank to collect water. See Continuous Water Drainage section.
Noise| Fan is working| Wind from the fan can create sounds during operation.
This is a normal sound.
www.jmatek.com
E-mail: support.eu@jmatek.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>