Naked NKD-pH Fresh Water Pool Systems Installation Guide
- June 9, 2024
- Naked
Table of Contents
NKD-pH Fresh Water Pool Systems
Installation Guide
pH Controller
INSTALLATION & STARTUP GUIDE
MODEL: NKD-pH
NKD-pH Fresh Water Pool Systems
NOTE:
- READ THIS DOCUMENT PRIOR TO INSTALLATION. IMPROPER INSTALLATION WILL VOID WARRANTY.
- PRODUCT ONLY TO BE INSTALLED & SERVICED BY A SUITABLY QUALIFIED PROFESSIONAL.
- THIS MANUAL CONTAINS IMPORTANT INFORMATION. ONCE INSTALLATION IS COMPLETE INSTALLER MUST PROVIDE THIS MANUAL TO OWNER/OPERATOR TO STORE IN A SAFE PLACE.
IMPORTANT – PLEASE READ!
This guide contains important information about the installation, operation
and safe use of this product. When installing and using this electrical
equipment, basic safety precautions should always be followed. Failure to
follow safety warnings and instructions in this manual can result in serious
injury and/or damage to the equipment. Read and follow all warning notices and
instructions that are included in this guide.
The NKD-pH Controller internally contains live components. There is a danger
of electric shock if opened. If the power cord is damaged then the
manufacturer, their agent or a similar qualified person in order to avoid a
hazard, should replace it. The product shall be installed according to AS/NZS
3000 wiring rules. It shall be installed outside the pool zone.
To reduce the risk of accidents or incidents, service on the unit should only
be performed by a qualified pool service professional and not operated by
children under 18 years of age.
WHEN MIXING ACID WITH WATER: ALWAYS ADD ACID TO WATER. NEVER ADD WATER TO
ACID. ACID/WATER MIX RATIO = 1 : 3
DO NOT PLUG UNIT IN IF CARTON HAS BEEN WET.
WE RECOMMEND STORING ACID DRUMS IN A SAFE PLACE PREFERABLY AT LEAST 2M AWAY
FROM ALL EQUIPMENT.
IF ACID IS STORED INSIDE ENSURE ADEQUATE VENTILATION.
WATER BALANCE GUIDELINES – Ideal Levels
Concrete | 7.4 – 7.6 | 500-700ppm | 80 – 150ppm | 200 – 250ppm |
---|---|---|---|---|
Fibreglass or Vinyl | 7.2 – 7.4 | 500-700ppm | 80 – 120ppm | 150 – 190ppm |
Pool Type | pH | Salt | Total Alkalinity | Calcium Hardness |
Specifications subject to change without notice. The contents of this manual
are the exclusive copyright of Naked Pools and may not be reproduced without
written© permission. 2021
Whilst every care was taken in preparation of this document, Naked Pools
accepts no responsibility for the accuracy of the information supplied.
PH CONTROLLER | PARTS SUMMARY
- pH Controller with Wall Mount Bracket
- Clear Tee with Lock Nut, Injector Valve c/w Sleeve & Tube Nut Injector O’Ring
- Clear PVC Flexible Tube (6m)
- Acid Drum Label
- Wall Plugs & Mounting Screws (x2)
- Drum Weight with Suction Valve c/w Tube Nut
- Installation and Start-up Guide
TOOLS REQUIRED
- Hacksaw 2 No.
- Phillips Head Screwdriver
- PVC Primer & Glue
- Drill & 6mm Drill Bit
TYPICAL SYSTEM INSTALLATION
Indicates direction of water flow
- Naked Control Unit
- OXI & ION Housing
- Filter
- Heater
- Pool Pump
- NKD-pH Controller
- Clear Injection Tee Piece
- Acid Drum with weighted Suction Valve and Label
- Clear PVC Flexible Tube
Before you start:
- NKD-pH uses a 1 : 3 Acid/Water mix ratio. Add 15L water then 5L of acid to a 20L drum. Always add acid to water, never water to acid.
- Install the Clear Injection Tee Piece before or after the OXI & ION Cell Housing taking note of the flow direction indicator.
- All installations must be after any heating.
- Store the acid drum at the furthest possible point away from all equipment.
INSTALLATION STEPS (Refer To Typical System Installation Diagram)
STEP 1 Attach Wall Mounting Bracket in the desired location for the NKD-
pH using the Wall Plugs and Mounting Screws provided.
STEP 2 Snap the pH Controller into the locating pins of the Mounting
Bracket.
STEP 3 Install the Clear Injection Tee Piece before or after the OXI &
ION Cell Housing taking note of the flow direction indicator. Note: This
should be installed after any heating.
STEP 4 Measure and cut the Clear Flexible PVC Tube for the Clear
Injection Tee Piece.
STEP 5 Use the remaining Clear Flexible PVC Tube for the acid drum,
keeping the acid drum a minimum of 2m from any equipment.
STEP 6 Drill a 6mm hole in the lid of the acid drum for the Clear PVC
Flexible Tube and attach Acid Drum Label to the cap.
STEP 7 Connect the Clear PVC Flexible Tube to the base of the peristaltic
pump (left side) and feed through the 6mm hole into the acid drum and attach
to the Acid Drum with weighted Suction Valve.
STEP 8 Connect the Clear Flexible PVC Tube to the base of the peristaltic
pump (right side) and attach to the Clear Injection Tee Piece.
STEP 9 Plug the pH Controller cable into the programming plug on the base
of the Naked Control Unit.
STEP 10 Plug the piggy back plug into the AC socket on the base of the
Naked Control Unit and then the pump into the piggy back plug.
OPERATING THE CONTROLLER
The NKD-pH is based on an algorithm and is designed to dose acid into the pool
each day based on a preset time in accordance with the pool size entered
during the Initial Start-up.
The pH controller will be activated each day when T1 starts and will run for
the preset time based on the pool size.
If pH levels are high, longer running times will be required, and similarly if
levels are low, run times will need to be decreased. Every swimming pool is
different depending on the set up and environment.
To change dosing times simply press [OK] for the Main Menu within the Naked
Control Unit and using the [+] and [-] buttons select M15 pH Control.
NOTE:
WHEN STARTING THE NKD-PH FOR THE FIRST TIME THE ACID PUMP WILL AUTOMATICALLY
PRIME WHEN THE INITIAL STARTUP BEGINS OR WHEN T1 IS ACTIVATED.
THERE ARE 2 MENUS FOR PH CONTROL
-
pH1 RUN TIME
· Adjusts the run time of the acid pump.
· Run time is displayed in minutes indicating the run time of the acid pump each day when T1 starts.
· If pH levels are high simply increase the time by pressing the [+] button.
· If pH levels are low simply decrease the time by pressing the [-] button.
Adjustments may be necessary, we recommend adjusting the Run Time by 1-2 minutes and checking pH levels until the correct levels are achieved. -
pH2 DEMAND or PRIME
· Used to manually dose acid or to prime the acid line after changing the acid drum.
· Displayed in ml, the default is 100ml and can be adjusted up to 5000ml.
· The acid pump will dose the required amount entered and once completed will return to the RUN TIME in pH1
· Calculate the amount of acid required by using the Dosing Calculator in the Naked Pools App. Simply select the ml required by pressing the [+] and [-] buttons and [OK] to confirm.
MAINTENANCE
It is important to understand a certain amount of owner maintenance and care
is required to keep your investment operating properly. We recommend the
following basic maintenance and further information can be found on the Naked
Pools App.
4.1 Injection Point on Injector Valve
Check the injection point periodically by inspecting the Clear Injection Tee
Piece for build-up of solid matter at the end of the PVC tubing. While
unscrewing the BLACK lock nut, take care not to lose the rubber O-ring.
4.2 Lubricate Squeeze Tube
Lubricate the pump squeeze tube every 3-6 months. Use a silicone-based
lubricant only as petroleum-based lubricants will cause damage to the tube and
rollers.
4.3 Replace Squeeze Tube
Depending on usage, the squeeze tube may need replacement after 1-2 years of
use. Before replacing, ensure that the suction and injection tubes are empty.
To replace the squeeze tube, please follow the instructions included with the
replacement kit, or on the Naked Pools App.
Only use original sized commercial grade Tygon® Norprene® tube as incorrect
sizing will result in early failure of the Tri Roller Block.
TECHNICAL SPECIFICATIONS
Volts Input (Vac) | 220-245 |
---|---|
Amps Input – Max. (Aac) | 1 |
Total Power Consumption (W) | 13W Motor – 20W Total |
Frequency (Hz) | 50 |
pH Controller Dimensions (mm) | 135W x 225H x 123D |
Output Controlled by Sanitiser (LPH) | 0-1.0 |
Rated Pressure (kPa) | 350 |
Squeeze Tube | Tygon® Norprene® (Commercial spec) |
Motor Speed (RPM) | 10 |
Non-Return Injector Valve | PVC with viton sleeve |
Tubing | 6m x 6mm Clear Flexible PVC Tube |
Roller Block | Heavy-duty PVC |
Power Cord | Approved piggy-back type |
Water Connection | 40/50mm |
Water Flow Rate (L/min) | 80-650 |
IP Rating | 34 |
Net Weight (kg) | 2.5 |
https://naked-pools.com/the-naked-app
SCAN THIS CODE TO GET THE
NAKED APP! or visit your App Store and search “Naked Pools” ****
Swimming as nature intendedTM
1800 625 331
support@naked-pools.com
www.naked-pools.com