Z-WAVE PLUS Minoston Smart Dimmer Switch Instruction Manual

June 7, 2024
Z-Wave Plus

Zwave plus

Z-WAVE PLUS Minoston Smart Dimmer Switch

Product

Federal Communications Commission (FCC) Statement
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

IC Caution:
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject
to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired
operation of the device.
DECLARATION DE CONFORMITE D’INDUSTRIE CANADA

WARRANTY

Evalogik Products warrants this product to be free from manufacturing defects for
a period of two years from the original date of consumer purchase. This warranty is limited to the repair or replacement of this product only and does not extend to consequential or incidental damage to other products that may be used with this product.
This warranty is in lieu of all other warranties, expressed or implied. Some states do not allow limitations on how long an implied warranty lasts or permit the exclusion or limitation
of incidental or consequential damage, so the above limitations may not apply to you.
This warranty gives you specific rights, and you may also have other rights which vary from state to state. if the unit should prove defective within the warranty period.

SPECIFICATIONS

Model: MS11ZS
Power: 120 VAC, 60 Hz.
Signal (Frequency): 908.42 MHZ.
Maximum load for outlet 500W Resistive
Maximum load for the Z-Wave™ controlled outlet:
Range: Up to 100 feet line of sight between the Wireless Control and the closest Z-Wave™ receiver module. Operating Temperature Range: 32-104° F (0-40° C)
Specifications subject to change without notice due to continuing product improvement
Website: www.nie-tech.com

WARNING

  • RISK OF FIRE

  • RISK OF ELECTRICAL SHOCK

  • RISK OF BURNS

  • CONTROLLING APPLIANCES:

  • EXERCISE EXTREME CAUTION WHEN USING Z-Wave™ DEVICES TO CONTROL APPLIANCES. OPERATION OF THE Z-Wave™ DEVICE MAY BE IN A DIFFERENT ROOM THAN THE CONTROLLED APPLIANCE, ALSO ANUNINTENTIONAL ACTIVATION MAY OCCUR IF THE WRONG BUTTON ON THE REMOTE IS PRESSED. Z-Wave™ DEVICES MAY AUTOMATICALLY BE POWERED ON DUE TO TIMED EVENT PROGRAMMING.

  • DEPENDING UPON THE APPLIANCE, THESE UNATTENDED OR UNINTENTIONAL OPERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS CONDITION. FOR THESE
    REASONS, WE RECOMMEND DO NOT RETURN THIS PRODUCT TO THE STORE
    THE FOLLOWING:

  • DO NOT USE Z-Wave™ DEVICES TO CONTROL ELECTRIC HEATERS OR ANY OTHER APPLIANCES WHICH MAY PRESENT A HAZARDOUS CONDITION DUE TO UNATTENDED OR UNINTENTIONAL OR AUTOMATIC POWER ON CONTROL.

Introduction:

This product can be operated in any Z-Wave network with other Z-Wave Plus™ certified devices from other manufacturers.
All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. Each module is designed to act as a repeater, which will re-transmit a radio frequency (RF) signal by routing the signal around obstacles and radio dead spots to ensure that the signal is received at its intended destination.
MS11ZS is a security enabled Z-Wave Plus™ device. A security Enabled Z-Wave Plus™ Controller must be used in order to fully utilize the product. The Device Type of the MS11ZS is on/off power switch.
The Role Type of the MS11ZS is Always On Slave Role Type

Key Features:

  • Remote ON/OFF control via the Z-Wave™ controller
  • Manual ON/OFF control with the front panel push button
  • Support Association Group and Auto Report switch status
  • Support firmware upgrades via Over-the-air (need Gateways support) —Support Scenes

Product Overview:

image

A. Up Push button
B. Down Push button
C. Load1 (Black)
D. Lin (Black) – Line in
E. Nin (White) – Neutral in
F. 3-way (RED)

MS11ZS Installation Wiring Diagram

image 2

Key function description

Function 1: Press the up or down button to turn the output ON or OFF
Function 2: quickly press 3x upper paddle: ADD(inclusion) (only if switch is not included in network)quickly press 3x lower paddle:Remove( exclusion)
Function 3: quickly press upper paddle 6x to change Status LED Configuration
Function 4: Press and hold lower paddle for 10 seconds, then LED starts blinking, release paddle and within 2 seconds, click lower paddle 5 times
(Node: Please use this procedure only when the network primary controller is missing or otherwise inoperable.)
Function 5: Tap A(1x/2x/3x/4x/5x/Hold/Release) Activate the scene.
Function 6: Tap B(1x/2x/3x/4x/5x/Hold/Release) Activate the scene.

Adding Your Device To A Hub

The device support two methods of inclusion, When using a Z-Wave Plus™ certified controller choose Network Wide Inclusion or SmartStart, Network Wide Inclusion To A Z-Wave™ Network

  1. Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.
  2. When prompted by your primary controller, click the Up or Down button three times in one second.

The device is compatible with SmartStart
SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave™ QR Code found on the top of the outlet or the back of the box with a controller providing SmartStart inclusion.No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on and in the network vicinity.

QR CODE
the QR code are sticked to the side of the case,DSK is included in the QR code.
DSK
The DSK code can be found on the DSK label which is attached on the packaging box.image 3

Command Class

table

Z-Wave™ Configuration Parameters

You may use the below configuration parameters to change settings of the corresponding functionality.

  1. Locally Button function
    Paramter No:       1(0x01)
    Size:                     1 Byte
    Value: 00(default) Up Button ON,Down Button OFF
    Value: 01              Up Button OFF,Down Button ON
    Value: 02              Up Button ON/OFF,Down Button ON/OFF

  2. Status LED Configuration
    Paramter No:                       2(0x02)
    Size:                                      1 Byte
    Value: 00(default)                Output and the LED are in the different state.
    Value: 01                             Output and the LED are in the same state.
    Value: 02                             LED Always OFF
    Value: 03                             LED Always ON

  3. Auto Turn-Off Timer
    Paramter No:                       3(0x03),
    Size=                                   4,
    Values:0                              (minutes) default;
    Values:                                1 – 65535 (minutes);

  4. Auto Turn-Off Timer
    Paramter No:                      5(0x05),
    Size=                                  4,
    Values:0                            (minutes) default;
    Values: 1                            – 65535 (minutes);

  5. Restores state after power failure
    Paramter No: 8                   (0x08)
    Size:                                    1 Byte
    Value: 00                            Output OFF.
    Value: 01                            Output ON.
    Value: 02                            (default) The state before a power outage.

  6. Ramp rate(Local Button + Z-Wave™)
    Paramter No:                            9(0x09),
    Size=1,Default =1
    Value=1                            from 0x63 to 0x00 or from 0x00 to 0x63 need 1s
    Value=2                            from 0x63 to 0x00 or from 0x00 to 0x63 need 2s
    ……
    Value=99                          from 0x63 to 0x00 or from 0x00 to 0x63 need 99s

  7. Multilevel minimum value can be set(Local Button)
    Paramter No:                            10(0x0A),
    Size=1,Default =1
    Value=0                            disable
    Value=1
    Value=2
    ……
    Value=99

  8. Multilevel maximum value can be set(Local Button)
    Paramter No:                            11(0x0B),
    Size=1,Default =99
    Value=0 disable
    Value=1
    Value=2
    ……
    Value=99

  9. Double Tap Behavior—when switch is off and quickly press UPPER paddle 2 times, switch turns on to x brightness
    Paramter No: 12(0x0C), Size=1,Default =0
    Value=0                            enable double tap to full brightness (99)
    Value=1                            custom value set in parameter 18
    Value=2                            enable double tap to maximum brightness (turn on to the value relate with parameter 11)
    Value=3                            disable double tap to full brightness

  10. Enable or Disable local / Z-Wave™ control
    Paramter No:                     15(0x0F) Size:1 ,Default =1
    Value: 00                            disable
    (when paddle pressed switch will not turn light on or off BUT it will still control the light via z-wave™ and it will change LED indicator status and on/off/multilevel status when paddle is pressed)
    Value: 01                            enable (normal operation like now)
    Value: 02                            disable local and Z-Wave™ control
    (LED and on/off status will still change if paddle pressed) > make sure that status is still reported and LED indicator changes when Z-Wave™ control is disabled

  11. dimmer speed (only for local press & hold)
    Paramter No:                     16(0x10),
    Size=1,                           Default =5
    Value=1                            from 0x63 to 0x00 or from 0x00 to 0x63 need 1s
    Value=2                            from 0x63 to 0x00 or from 0x00 to 0x63 need 2s
    ……
    Value=99 from 0x63 to 0x00 or from 0x00 to 0x63 need 99s

  12. Custom brightness level– in this parameter define default brightness level the switch will turn on to from main switch or regular switch in 3-way when pressed upper paddle once.
    Paramter No:                   18(0x12), Size=1,Default =0
    Value=0                            last brightness level
    Value=(1–99)                   custom brightness level

  13. 3-way switch type
    Paramter No:                19(0x13) Size:1 ,Default =0
    Value: 00                       toggle switch
    Value: 01                       toggle switch
    press 1x change device status; quickly press 2x the result depend on Par11/Par12; quickly Press 3x it trigger dimmer in loop
    Value: 02                       momentary switch
    press 1x change device status; quickly press 2x the result depend on Par11/Par12;hold trigger dimmer in loop
    Value: 03                       momentary switch
    press 1x change device status;quickly press 2x the result depend on Par11/Par12;hold trigger dimmer in loop(dimmer up/dimmer down –
    BUT after double click to full brightness, hold will dim DOWN always instead of trying to increase brightness)

  14. Association reports
    Paramter No:                  20(0x14) Size:1 ,Default =2
    Value: 00           Z-Wave™ control:Multilevel report (without each level,just final level)
    Manual control (short press): Basic report(without each level,just final level)
    Manual control(long press & relay enable): Basic report(without each level,just final level)
    Manual control(long press & relay disable): Multilevel report (each level will be reported)
    Value: 01           Z-Wave™ control:Multilevel report (without each level,just final level)
    Manual control (short press): Basic report(without each level,just final level)
    Manual control(long press & relay enable OR disable): Basic report
    Value: 02           Z-Wave™ control:Multilevel report (without each level, just final level)
    Manual control (short press): Multilevel report (without each level, just final level)
    Manual control (long press & relay enable): Multilevel report (without each level, just final level)
    Manual control (long press & relay disable): Multilevel report (each level will be reported)

  15. Disabled Relay Behavior
    Paramter No:        21(0x15)
    Size:                      1 ,Default =0
    Value: 00               report on/off and multilevel status when paddle is pressed and change LED indicator status and Parameter 15 is set to value 0 or 2 (output control disabled) according to setting in Parameter 20
    Value: 01               Don’t report on/off or multilevel status or and change LED indicator status when paddle is pressed and Parameter 15 is set to value 0 or 2 (output control disabled).

  16. Night Mode Brightness Level—Set the level of brightness the dimmer will turn on to when off and lower paddle held DOWN for 2 seconds
    Paramter No: 22(0x16) Size:1 ,Default =0
    Value: 00                     disable function
    Value: 01-99

  17. LED Indicator Color
    Paramter No: 23(0x17), Size=1,Default =1
    Value=0                     White
    Value=1                     Blue
    Value=2                     Green
    Value=3 Red

  18. LED Indicator Brightness
    Paramter No:                     26(0x18), Size=1,Default =1
    Value=0                     Bright (100%)
    Value=1                     Medium (60%)
    Value=2                     Low (30%)

  19. Single Tap Behavior: when switch is off and press UPPER paddle 1 time, switch turns on to x brightness(Local Button)
    Paramter No: 27(0x19), Size=1,Default =0
    Value=0                     last brightness level
    Value=1                     custom value set in parameter 18
    Value=2                     maximum brightness set in parameter 11
    Value=2                     full 100% brightness

Restoring Factory Defaults

MS11ZS is removed from the network and will be restored to the factory setting
All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network.
Manual Reset: Press and hold lower paddle for 10 seconds, then LED starts blinking, release paddle and within 2 seconds, click lower paddle 5 times
Remark : All the setting and data will be permanently deleted.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.

Zwave plus

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals