Z-WAVE PLUS Minoston Smart Dimmer Switch Instruction Manual
- June 7, 2024
- Z-Wave Plus
Table of Contents
- Z-WAVE PLUS Minoston Smart Dimmer Switch
- WARRANTY
- SPECIFICATIONS
- Introduction:
- Key Features:
- Product Overview:
- MS11ZS Installation Wiring Diagram
- Key function description
- Command Class
- Z-Wave™ Configuration Parameters
- Restoring Factory Defaults
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Z-WAVE PLUS Minoston Smart Dimmer Switch
Federal Communications Commission (FCC) Statement
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this
equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two
conditions: (1) This device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may
cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures: Reorient or relocate
the receiving antenna. Increase the separation between the equipment and
receiver. Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected. Consult the dealer or an experienced
radio/TV technician for help. This equipment should be installed and operated
with minimum distance 20cm between the radiator and your body.
IC Caution:
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject
to the following two conditions: (1) this device may not cause interference,
and (2) this device must accept any interference, including interference that
may cause undesired
operation of the device.
DECLARATION DE CONFORMITE D’INDUSTRIE CANADA
WARRANTY
Evalogik Products warrants this product to be free from manufacturing defects
for
a period of two years from the original date of consumer purchase. This
warranty is limited to the repair or replacement of this product only and does
not extend to consequential or incidental damage to other products that may be
used with this product.
This warranty is in lieu of all other warranties, expressed or implied. Some
states do not allow limitations on how long an implied warranty lasts or
permit the exclusion or limitation
of incidental or consequential damage, so the above limitations may not apply
to you.
This warranty gives you specific rights, and you may also have other rights
which vary from state to state. if the unit should prove defective within the
warranty period.
SPECIFICATIONS
Model: MS11ZS
Power: 120 VAC, 60 Hz.
Signal (Frequency): 908.42 MHZ.
Maximum load for outlet 500W Resistive
Maximum load for the Z-Wave™ controlled outlet:
Range: Up to 100 feet line of sight between the Wireless Control and the
closest Z-Wave™ receiver module. Operating Temperature Range: 32-104° F (0-40°
C)
Specifications subject to change without notice due to continuing product
improvement
Website: www.nie-tech.com
WARNING
-
RISK OF FIRE
-
RISK OF ELECTRICAL SHOCK
-
RISK OF BURNS
-
CONTROLLING APPLIANCES:
-
EXERCISE EXTREME CAUTION WHEN USING Z-Wave™ DEVICES TO CONTROL APPLIANCES. OPERATION OF THE Z-Wave™ DEVICE MAY BE IN A DIFFERENT ROOM THAN THE CONTROLLED APPLIANCE, ALSO ANUNINTENTIONAL ACTIVATION MAY OCCUR IF THE WRONG BUTTON ON THE REMOTE IS PRESSED. Z-Wave™ DEVICES MAY AUTOMATICALLY BE POWERED ON DUE TO TIMED EVENT PROGRAMMING.
-
DEPENDING UPON THE APPLIANCE, THESE UNATTENDED OR UNINTENTIONAL OPERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS CONDITION. FOR THESE
REASONS, WE RECOMMEND DO NOT RETURN THIS PRODUCT TO THE STORE
THE FOLLOWING: -
DO NOT USE Z-Wave™ DEVICES TO CONTROL ELECTRIC HEATERS OR ANY OTHER APPLIANCES WHICH MAY PRESENT A HAZARDOUS CONDITION DUE TO UNATTENDED OR UNINTENTIONAL OR AUTOMATIC POWER ON CONTROL.
Introduction:
This product can be operated in any Z-Wave network with other Z-Wave Plus™
certified devices from other manufacturers.
All non-battery operated nodes within the network will act as repeaters
regardless of vendor to increase reliability of the network. Each module is
designed to act as a repeater, which will re-transmit a radio frequency (RF)
signal by routing the signal around obstacles and radio dead spots to ensure
that the signal is received at its intended destination.
MS11ZS is a security enabled Z-Wave Plus™ device. A security Enabled Z-Wave
Plus™ Controller must be used in order to fully utilize the product. The
Device Type of the MS11ZS is on/off power switch.
The Role Type of the MS11ZS is Always On Slave Role Type
Key Features:
- Remote ON/OFF control via the Z-Wave™ controller
- Manual ON/OFF control with the front panel push button
- Support Association Group and Auto Report switch status
- Support firmware upgrades via Over-the-air (need Gateways support) —Support Scenes
Product Overview:
A. Up Push button
B. Down Push button
C. Load1 (Black)
D. Lin (Black) – Line in
E. Nin (White) – Neutral in
F. 3-way (RED)
MS11ZS Installation Wiring Diagram
Key function description
Function 1: Press the up or down button to turn the output ON or OFF
Function 2: quickly press 3x upper paddle: ADD(inclusion) (only if switch
is not included in network)quickly press 3x lower paddle:Remove( exclusion)
Function 3: quickly press upper paddle 6x to change Status LED
Configuration
Function 4: Press and hold lower paddle for 10 seconds, then LED starts
blinking, release paddle and within 2 seconds, click lower paddle 5 times
(Node: Please use this procedure only when the network primary controller is
missing or otherwise inoperable.)
Function 5: Tap A(1x/2x/3x/4x/5x/Hold/Release) Activate the scene.
Function 6: Tap B(1x/2x/3x/4x/5x/Hold/Release) Activate the scene.
Adding Your Device To A Hub
The device support two methods of inclusion, When using a Z-Wave Plus™ certified controller choose Network Wide Inclusion or SmartStart, Network Wide Inclusion To A Z-Wave™ Network
- Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.
- When prompted by your primary controller, click the Up or Down button three times in one second.
The device is compatible with SmartStart
SmartStart enabled products can be added into a Z-Wave network by scanning the
Z-Wave™ QR Code found on the top of the outlet or the back of the box with a
controller providing SmartStart inclusion.No further action is required and
the SmartStart product will be added automatically within 10 minutes of being
switched on and in the network vicinity.
QR CODE
the QR code are sticked to the side of the case,DSK is included in the QR
code.
DSK
The DSK code can be found on the DSK label which is attached on the packaging
box.
Command Class
Z-Wave™ Configuration Parameters
You may use the below configuration parameters to change settings of the corresponding functionality.
-
Locally Button function
Paramter No: 1(0x01)
Size: 1 Byte
Value: 00(default) Up Button ON,Down Button OFF
Value: 01 Up Button OFF,Down Button ON
Value: 02 Up Button ON/OFF,Down Button ON/OFF -
Status LED Configuration
Paramter No: 2(0x02)
Size: 1 Byte
Value: 00(default) Output and the LED are in the different state.
Value: 01 Output and the LED are in the same state.
Value: 02 LED Always OFF
Value: 03 LED Always ON -
Auto Turn-Off Timer
Paramter No: 3(0x03),
Size= 4,
Values:0 (minutes) default;
Values: 1 – 65535 (minutes); -
Auto Turn-Off Timer
Paramter No: 5(0x05),
Size= 4,
Values:0 (minutes) default;
Values: 1 – 65535 (minutes); -
Restores state after power failure
Paramter No: 8 (0x08)
Size: 1 Byte
Value: 00 Output OFF.
Value: 01 Output ON.
Value: 02 (default) The state before a power outage. -
Ramp rate(Local Button + Z-Wave™)
Paramter No: 9(0x09),
Size=1,Default =1
Value=1 from 0x63 to 0x00 or from 0x00 to 0x63 need 1s
Value=2 from 0x63 to 0x00 or from 0x00 to 0x63 need 2s
……
Value=99 from 0x63 to 0x00 or from 0x00 to 0x63 need 99s -
Multilevel minimum value can be set(Local Button)
Paramter No: 10(0x0A),
Size=1,Default =1
Value=0 disable
Value=1
Value=2
……
Value=99 -
Multilevel maximum value can be set(Local Button)
Paramter No: 11(0x0B),
Size=1,Default =99
Value=0 disable
Value=1
Value=2
……
Value=99 -
Double Tap Behavior—when switch is off and quickly press UPPER paddle 2 times, switch turns on to x brightness
Paramter No: 12(0x0C), Size=1,Default =0
Value=0 enable double tap to full brightness (99)
Value=1 custom value set in parameter 18
Value=2 enable double tap to maximum brightness (turn on to the value relate with parameter 11)
Value=3 disable double tap to full brightness -
Enable or Disable local / Z-Wave™ control
Paramter No: 15(0x0F) Size:1 ,Default =1
Value: 00 disable
(when paddle pressed switch will not turn light on or off BUT it will still control the light via z-wave™ and it will change LED indicator status and on/off/multilevel status when paddle is pressed)
Value: 01 enable (normal operation like now)
Value: 02 disable local and Z-Wave™ control
(LED and on/off status will still change if paddle pressed) > make sure that status is still reported and LED indicator changes when Z-Wave™ control is disabled -
dimmer speed (only for local press & hold)
Paramter No: 16(0x10),
Size=1, Default =5
Value=1 from 0x63 to 0x00 or from 0x00 to 0x63 need 1s
Value=2 from 0x63 to 0x00 or from 0x00 to 0x63 need 2s
……
Value=99 from 0x63 to 0x00 or from 0x00 to 0x63 need 99s -
Custom brightness level– in this parameter define default brightness level the switch will turn on to from main switch or regular switch in 3-way when pressed upper paddle once.
Paramter No: 18(0x12), Size=1,Default =0
Value=0 last brightness level
Value=(1–99) custom brightness level -
3-way switch type
Paramter No: 19(0x13) Size:1 ,Default =0
Value: 00 toggle switch
Value: 01 toggle switch
press 1x change device status; quickly press 2x the result depend on Par11/Par12; quickly Press 3x it trigger dimmer in loop
Value: 02 momentary switch
press 1x change device status; quickly press 2x the result depend on Par11/Par12;hold trigger dimmer in loop
Value: 03 momentary switch
press 1x change device status;quickly press 2x the result depend on Par11/Par12;hold trigger dimmer in loop(dimmer up/dimmer down –
BUT after double click to full brightness, hold will dim DOWN always instead of trying to increase brightness) -
Association reports
Paramter No: 20(0x14) Size:1 ,Default =2
Value: 00 Z-Wave™ control:Multilevel report (without each level,just final level)
Manual control (short press): Basic report(without each level,just final level)
Manual control(long press & relay enable): Basic report(without each level,just final level)
Manual control(long press & relay disable): Multilevel report (each level will be reported)
Value: 01 Z-Wave™ control:Multilevel report (without each level,just final level)
Manual control (short press): Basic report(without each level,just final level)
Manual control(long press & relay enable OR disable): Basic report
Value: 02 Z-Wave™ control:Multilevel report (without each level, just final level)
Manual control (short press): Multilevel report (without each level, just final level)
Manual control (long press & relay enable): Multilevel report (without each level, just final level)
Manual control (long press & relay disable): Multilevel report (each level will be reported) -
Disabled Relay Behavior
Paramter No: 21(0x15)
Size: 1 ,Default =0
Value: 00 report on/off and multilevel status when paddle is pressed and change LED indicator status and Parameter 15 is set to value 0 or 2 (output control disabled) according to setting in Parameter 20
Value: 01 Don’t report on/off or multilevel status or and change LED indicator status when paddle is pressed and Parameter 15 is set to value 0 or 2 (output control disabled). -
Night Mode Brightness Level—Set the level of brightness the dimmer will turn on to when off and lower paddle held DOWN for 2 seconds
Paramter No: 22(0x16) Size:1 ,Default =0
Value: 00 disable function
Value: 01-99 -
LED Indicator Color
Paramter No: 23(0x17), Size=1,Default =1
Value=0 White
Value=1 Blue
Value=2 Green
Value=3 Red -
LED Indicator Brightness
Paramter No: 26(0x18), Size=1,Default =1
Value=0 Bright (100%)
Value=1 Medium (60%)
Value=2 Low (30%) -
Single Tap Behavior: when switch is off and press UPPER paddle 1 time, switch turns on to x brightness(Local Button)
Paramter No: 27(0x19), Size=1,Default =0
Value=0 last brightness level
Value=1 custom value set in parameter 18
Value=2 maximum brightness set in parameter 11
Value=2 full 100% brightness
Restoring Factory Defaults
MS11ZS is removed from the network and will be restored to the factory setting
All Configuration Parameters values and Association information will be
restored to factory default settings and excluded from the network.
Manual Reset: Press and hold lower paddle for 10 seconds, then LED starts
blinking, release paddle and within 2 seconds, click lower paddle 5 times
Remark : All the setting and data will be permanently deleted.
Please use this procedure only when the network primary controller is missing
or otherwise inoperable.
References