Indy ChromaControlTM luminaires with the -BTA, -DMXA, and -ECOA option are individually controllable through specific control systems. These options allow the customer to individually address, control, and manipulate the light on a luminaire-per-luminaire basis. Indy ChromaContro| M luminaires paired with these options can be controlled by the following systems: Bluetooth, DMX, and Ecosystem.

Bluetooth Enabled Luminaire

  1. Install ChromaControl luminaire by following guidelines in supplied installation guide.
  2. Supply power to luminaire.
  3. Use the Indy™ ChromaControl™ App to commission the luminaire.
  4. Refer to instruction sheet 065-1267 for using the Indy™ ChromaControl App.
  5. Refer to instruction sheet 065-1141 for connecting 0-10V DIM/CT control (if desired), and 065-1140 for remote control.

Lutron Ecosystem Enabled Luminaire (Color Tuning/Black Body Dimming)

  1. Install ChromaControl luminaire by following guidelines in supplied installation guide.
  2. Connect Ecosystem E1 and E2 wires from Ecosystem controller (not provided) to Luminaire by wiring the connection inside the luminaire junction box. Figure 1
  3. Supply power to the luminaire.
  4. Commission the luminaire using the EcoSystem controller
  5. Single channel for Black Body Dimming luminaires (dimming control only)
  6. Two channel for Color Tuning luminaires (dimming and CCT control)

For instructions on how to download the lndy™ ChromaControl App and to commission ChromaControl luminaries with your device, please refer to instruction sheet 065-1267 (For BTA and DXMA only).

EcoSystem wires on Luminaire (ECOA)

indy-LRM4-VC-VW-ChromaControl-Luminaires-FIG-1

EcoSystem wires on Luminaire (ECOA)

indy-LRM4-VC-VW-ChromaControl-Luminaires-FIG-2

DMX Enabled Luminaire:

  1. Install ChromaControl luminaire by following guidelines in supplied installation guide.
  2. Connect DMX wires from DMX controller (not provided) to Luminaire by wiring the connection inside the luminaire junction box: Figure 2
  3. J-Box and whip assembly (IN and Out Sets) – White/Blue (Data +), Blue/White (Data -), Drain Wire (Data Common) (see termina t ion resistor wiring diagram,
  4. Use DMX/RS485 rated cable for field connections. Some recommended cables include
  5. Liberty Cable – 24-2P-485 Non-Plenum, 24-2P-P485 Plenum
  6. Belden Cable – 9842 Non-Plenum, 89842 Plenum
  7. Supply power to the luminaire.
  8. Commission the luminaire using the DMX controller, with the default slot settings below:
  9. DIMMING
  10. CCT
  11. SATURATION
  12. HUE

For instructions on how to download the lndy™ ChromaControl App and to commission ChromaControl luminaries with your device, please refer to instruction sheet 065-1267 (For BTA and DXMA only).

DMX wires on Luminaire (DMXA)

indy-LRM4-VC-VW-ChromaControl-Luminaires-FIG-3

DMX wires on Luminaire (DMXA)

indy-LRM4-VC-VW-ChromaControl-Luminaires-FIG-4

DMX INTERNAL WIRING

indy-LRM4-VC-VW-ChromaControl-Luminaires-FIG-5

Indy ChromaControlTM luminaires with the-BTA, -DMXA, and -ECOA option are individually controllable through specific control systems. These options allovw the customer to individually address, control, and manipulate the light on a luminaire-per-luminaire basis. Indy ChromaControlTM luminaires paired with these options can be controlled by the following systems: Bluetooth, DMX, and Ecosystem.

Bluetooth Enabled Cylinders

  1. Install ChromaControl luminaire by following guidelines in supplied installation guide.
  2. Supply power to luminaire.
  3. Use the IndyTM ChromaControl TM App to commission the luminaire.
  4. Refer to instruction sheet 065-1267 for using the lIndyTM ChromaControl App.
  5. Refer to instruction sheet 065-1141 for connecting 0-10V DIM/CT control (if desired), and 065-1140 for remote control.

Lutron Ecosystem Enabled Cylinders (Color Tuning/Black Body Dimming)

  1. Install ChromaControl luminaire by following guidelines in supplied installation guide
  2. Connect Ecosystem E1 and E2 wires from Ecosystem controler (not provided) to Luminaire by wiring the connection inside the luminaire junction box. Figure 1
  3. Supply power to the luminaire.
  4. Commission the luminaire using the EcoSystem controller
  5. Single channel for Black Body Dimming luminaires (dimming control only)
  6. Two channel for Color Tuning luminaires (dimming and CCT control)
EcoSystem wires on Cylinders (ECOA)

indy-LRM4-VC-VW-ChromaControl-Luminaires-FIG-6

  1. Install ChromaControl luminaire by following guidelines in supplied installation guide.
  2. Connect DMX wires from DMX controller (not provided) to Luminaire by wiring the connection inside the luminaire junction box: Figure 2
  3. J-Box and whip assembly (IN and Out Sets) – White/Blue (Data +), Blue/White (Data -), Drain Wire (Data Common) (see termina t ion resistor wiring diagram,
  4. Use DMX/RS485 rated cable for field connections. Some recommended cables include
  5. Liberty Cable – 24-2P-485 Non-Plenum, 24-2P-P485 Plenum
  6. Belden Cable – 9842 Non-Plenum, 89842 Plenum
  7. Supply power to the luminaire.
  8. Commission the luminaire using the DMX controller, with the default slot settings below:
  9. DIMMING
  10. CCT
  11. SATURATION
  12. HUE

For instructions on how to download the lndy™ ChromaControl App and to commission ChromaControl luminaries with your device, please refer to instruction sheet 065-1267 (for BTA and DXMA only).

DMX wires on Cylinders (DMXA)

indy-LRM4-VC-VW-ChromaControl-Luminaires-FIG-7

DMX INTERNAL WIRING

indy-LRM4-VC-VW-ChromaControl-Luminaires-FIG-8

1300 S. Wolf Road Des Plaines, IL 60018 Phone 800-323-5068 Visit us at www.acuitybrands.com/Indy ©2017 Acuity Brands Lighting, Inc. Rev 11/06 065-1270

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals