ELKAY LBWD2C00WHC In-wall Filtered Water Dispenser 220-240V Instruction Manual

June 9, 2024
ELKAY

LBWD2C00WHC In-wall Filtered Water Dispenser 220-240V

LBWD2C00BKC LBWD2C00WHC
Installation Manual
ezH2O® Liv Pro Commercial In-wall Filtered Water Dispenser 220-240V

LBWD2C00BKC

LBWD2C00WHC

630-574-8484

1

Installation Manual (1000005849 Rev. C – 02/22)

Elkay Manufacturing Company In-Wall Filtered Water Dispenser

LBWD2C00BKC LBWD2C00WHC

Elkay Manufacturing Company In-Wall Filtered Water Dispenser

2

630-574-8484

Installation Manual (1000005849 Rev. C – 02/22)

LBWD2C00BKC LBWD2C00WHC
Contents

1. General Information. . . . . . . . . . . . . . . . . . . . . . . . 3 1.1 Installation Manual . . . . . . . . . . . . . . . . . . . . . 3
1.2 Models Covered in Manual . . . . . . . . . . . . . . . 3
1.3 Serial Number Location . . . . . . . . . . . . . . . . . 4 1.4 Contact Information. . . . . . . . . . . . . . . . . . . . . 4
1.5 Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.6 Notice of Changes . . . . . . . . . . . . . . . . . . . . . 4
1.7 Radio Frequency Compliance. . . . . . . . . . . . . 4
1.8 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.9 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2. Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.2 Safety Alert Symbol. . . . . . . . . . . . . . . . . . . . . 5 2.3 Personal Safety. . . . . . . . . . . . . . . . . . . . . . . . 5
2.4 Property Damage . . . . . . . . . . . . . . . . . . . . . . 6
1. General Information
This hands-free water dispenser serves healthier, filtered water in a sustainable way with stylish in-wall installation. It is designed for commercial and hospitality environments such as lobbies and conference rooms.
1.1 Installation Manual Read all instructions carefully BEFORE starting the installation and familiarize yourself with the various parts of this product.
The installation of this product requires electrical and plumbing connections that use specific skills and knowledge. If you are unsure or not qualified to make these connections, consult a qualified plumber, electrician, or installer. Professional installation is suggested.
This manual contains step-by-step installation instructions for the In-wall Water Dispenser. Followed carefully, these instructions will result in trouble-free installation of this Elkay Manufacturing Company (Elkay) product. Additional use and care documents can be found on the Elkay website at http://www.elkay.com/support.
Any deviations, additions, or deletions from the described methods, without the prior written approval of our Customer Care department, will void the warranty covering this product.

3. Installation Preparation – Read Before Beginning Installation . . . . . . . . . . . . . . . . . . . . . . 7
4. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 4.1 Tools Required . . . . . . . . . . . . . . . . . . . . . . . . 8 4.2 Parts Required not Included . . . . . . . . . . . . . . 8 4.3 Critical Depth Check . . . . . . . . . . . . . . . . . . . . 8 4.4 Cutting Size and Mounting Dimensions . . . . . 9 4.5 Plumbing and Electrical Key . . . . . . . . . . . . . . 9 4.6 Water Dispenser Installation . . . . . . . . . . . . . . 9 4.7 Installing the Remote Filter . . . . . . . . . . . . . . 10 4.8 Installing with Remote Water Chiller (optional) . . . . . . . . . . . . . . . . . . . . . . 12 4.9 Connecting Catch Basin Drain (optional) . . . 12
5. Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 6. Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . 17

Make sure the installation and use of this product meet all local, state, and federal plumbing and electrical codes.
WARNING

Carefully read, understand, and follow all the instructions in this manual before using the product. Improper installation, use, or maintenance of this product could cause a dangerous situation resulting in personal injury or even death.
Do not operate power tools unless you read and understand the instructions and warnings in this and all other applicable manuals. Proper use of tools and the products described in this manual is your responsibility.

NOTICE

Failure to follow these instructions could also cause a situa-

tion that results in water damage, or other damage to floors, walls, pipes, or electrical wiring.

1.2 Models Covered in Manual

LBWD2C00BKC LBWD2C00WHC

Midnight Aspen White

630-574-8484

3

Installation Manual (1000005849 Rev. C – 02/22)

Elkay Manufacturing Company In-Wall Filtered Water Dispenser

LBWD2C00BKC LBWD2C00WHC

1.3 Serial Number Location
Please locate the serial number located under the front panel, as shown and use this serial number when contacting us with questions concerning the installation of this product.

1.6 Notice of Changes
The information, specifications, and illustrations in this manual are based on the information that was available at the time this material was written and can change at any time.

Dimensions are given in inches (“) and millimeters (mm).

1.4 Contact Information
General Information Elkay Manufacturing Company 1333 Butterfield Rd. Suite 200 Downers Grove, IL 60515
Phone: 630.574.8484 Phone: 1800.260.6640 (Repair Service) Email: consumer@elkay.com Website: http://www.elkay.com
USA/Canada Customer Care Phone: 800.476.4106 Email: CustCare@Elkay.com
International Customer Care Phone: 630.575.4755 Email: IntlCare@Elkay.com
Installation Services Phone: 800.952.8064 Email: installservice@elkay.com Website: http://www.elkay.com/contact-us/install
1.5 Disclaimer
The information contained in this manual is given free of charge. This information is based on reliable technical data and is intended for people with the technical knowledge to install, use, and maintain this product at their own discretion and risk. Elkay assumes no responsibility for results obtained or damage incurred from the use of this material either in whole or in part by the buyer.

1.7 Radio Frequency Compliance
The water dispenser and filter communicate with each other through a Near Field Communication (NFC) device. This short-range, wireless connectivity technology is designed to monitor the status of the filter and to alert the user when it is time to change the filter. The NFC device operates in a frequency of 13.56MHz. The maximum radiated field strength of NFC device is 30.87dBuV/m.
This device complies with Radio Equipment Directive 2014/53/EU. The full text of the EU declaration of conformity is available with this device.
Operation is subject to the following two (2) conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not approved by the manufacturer could void the user’s authority to operate the equipment.
1.8 Warranty
This product is covered by a Limited Warranty and Elkay will not be held responsible for damage of any kind in connection with the installation of the product. The warranty statement is in the Use and Care manual.
1.9 Definitions
DANGER – Indicates death or serious injury will result if proper precautions are not taken.
WARNING – Indicates death, serious injury or property damage can result if proper precautions are not taken.
CAUTION – Indicates some injury or property damage may result if proper precautions are not taken.
Authorized Service Personnel ­ Factory trained personnel or personnel having working knowledge of electrical, plumbing and machine (appliance) maintenance procedures.

Elkay Manufacturing Company In-Wall Filtered Water Dispenser

4

630-574-8484

Installation Manual (1000005849 Rev. C – 02/22)

LBWD2C00BKC LBWD2C00WHC

2. Safety

THINK SAFETY!

Think Safety
Before performing any work, read and understand the safety instructions in this manual.

2.1 General
The Elkay Manufacturing Company (Elkay) cannot anticipate every possible circumstance that might involve a potential hazard during the installation or maintenance of this product. The warnings and instructions in this Installation Manual are, therefore, not all-inclusive. If a tool, installation procedure, or work method that is not specifically recommended by Elkay is used, you must be satisfied that it is safe for yourself and others. You should also make sure that the product will not be damaged by the methods you choose.
Most work-related accidents are caused by failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing potentially hazardous situations before an accident occurs. As you install and maintain this product, you must be alert to potential hazards. You should also have the necessary training, skills, and tools to perform any installation or maintenance procedure.
2.2 Safety Alert Symbol
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
This manual contains WARNINGS, CAUTIONS, NOTICES, SAFETY INSTRUCTIONS, and NOTES which must be followed to prevent the possibility of improper service, damage to the equipment, personal injury, or death. The following keywords call the reader’s attention to potential hazards.
Hazards are identified by the “Safety Alert Symbol” and followed by a signal word such as “WARNING” or “CAUTION”.
2.3 Personal Safety
DANGER
· Please read these instructions completely before starting the installation or performing any service. Failure to follow the instructions and safety precautions in this manual can result in serious injury or death.

· After installation, keep these instructions in a safe location for future reference.
· Electric supply must be identical in voltage, cycle, and phase to that specified on nameplate.
· Electrical supply must have Ground Fault Circuit Interrupter (GFCI) protection.
· A means for disconnecting electrical supply to the unit must be incorporated in the fixed wiring in accordance with wiring rules. This is to allow electrical disconnection of the unit from electrical supply after installation.
WARNING
These warnings indicate a potentially hazardous situation which, if not avoided, could result in serious injury or death. Follow all instructions related to the installation and/or maintenance of this product (unit).
For use with clean, clear potable drinking water only. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before the system.
Installation and connection to water and electrical mains must be in compliance with local and national laws.
All Installation and Service work must be performed by an authorized service personnel.
Personal Protection Be sure to use all personal protective equipment, such as sturdy safety glasses, work shoes, hearing protection, and cut resistant gloves, whenever necessary, to ensure your own safety.
To avoid eye injury, always wear protective glasses with side shields when using power tools. Also, make sure no one else can be injured by flying particles when using power tools.
Always wear ear protection, such as earmuffs or earplugs, when using power tools.
Wear protective cut resistant gloves during installation to protect against sharp edges from sheet metal components.
Power Tool Hazard To prevent personal injury or possible death, always follow the electrical safety recommendations of the power tool’s manufacturer. · Do not use power tools in an unsafe manner.

630-574-8484

5

Installation Manual (1000005849 Rev. C – 02/22)

Elkay Manufacturing Company In-Wall Filtered Water Dispenser

LBWD2C00BKC LBWD2C00WHC

· Power tools should only be connected to a circuit protected by a ground- fault circuit interrupter (GFCI).
· If an extension cord is required, always use an appropriate extension cord.
Shock and Electrocution Hazards Failure to follow these instructions could result in severe electrical burns, significant injuries, and even death.
Water will conduct electric current to create a short circuit, resulting in injury or death.
· Never use electric power tools around water or wet floors/surfaces.
· Keep all liquids away from electrical cords and power tools.
· If an extension cord is required, always use an appropriate extension cord.
· DO NOT create a short circuit between a source of electricity and a liquid by being in contact with both simultaneously.
WARNING
Contacting live electrical wiring with power tools or hand tools can cause serious injury or death.
· Make sure all related circuit breakers are turned OFF.
· Test for live circuits or wiring inside any wall where installation of the product requires cutting into a wall.
Prior to any maintenance, make sure the unit is disconnected from the power source and the circuit breaker is turned OFF.

a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
To prevent a metallic taste or increased metal content in the water due to an electrolysis process caused by electrical feedback from the grounding of electrical equipment to water supply and water waste mains, connect to these mains using non-conductive materials. The provided Filter meets this requirement.
Tripping Hazard Personal injury can result from tripping over power cords, tools, or other installation items. DO NOT leave items laying around the work area.
Cutting Hazard The installation of this product requires using power tools.
Keep hands away from the cutting edge of any tool used in the installation of our product.
Placing fingers in or around the cutting blades could result in serious personal injury.
Use Proper Tools Always use proper tools which are in good working condition during the installation of the product.
2.4 Property Damage
NOTICE
Inspect Before Cutting Make sure no electrical wiring or plumbing is present before cutting into a wall.

Prior to installation, test for live circuits or wiring inside the wall before cutting or drilling into the wall. Before working near any electrical circuit or wiring, remove all power and use a circuit tester to verify the power has been disconnected. Contact with live electricity can cause serious bodily injury and in some cases death.

CAUTION
These cautions indicate a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Follow all instructions related to installation and/or maintenance of this product.

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge if they have been given supervision or instructions concerning use of the appliance in

Elkay Manufacturing Company In-Wall Filtered Water Dispenser

6

630-574-8484

Installation Manual (1000005849 Rev. C – 02/22)

LBWD2C00BKC LBWD2C00WHC

3. Installation Preparation – Read Before Beginning Installation

For correct and safe installation, please read these instructions completely.
DANGER
· All Installation work must be performed by an authorized service personnel.
· Disconnect electrical supply serving the Installation area to reduce risk of electrocution.
· Unit not suitable for installations where water jets could be used.
WARNING
· Shut off water supply serving the Installation area to reduce risk of water damage.
· Ensure proper ventilation by maintaining clearance from cabinet louvers to wall on each side of Cooler as specified in Rough-In.
· Never wire compressor directly to electrical supply.
· Thoroughly flush all water lines and fittings of all foreign matter before connecting to Cooler.
· Warranty is void if Installation is not made in accordance with current Manufacturing instructions.
CAUTION
· Hose-sets are not to be used for connecting to water mains.
· If inlet pressure is above 105 psig (0.72 MPa), a pressure regulator must be installed in water supply line. Any damage caused by reason of connecting this product to water supply line pressure outside it’s rated pressure, is not covered by warranty.
· Tools/Items required but not provided.
– Water Shut-off Valve with 3/8″ (9.5mm) compression outlet.
– Waste Trap (non-metallic)
– Safety Glasses
– Protective Gloves
– Hex drives
– Fasteners for wall type

NOTICE

The installation of this product requires electrical and plumbing

connections that use specific skills and knowledge. If

you are unsure or not qualified to make these

connections, consult a qualified plumber, electrician,

or installer for this installation. Professional

installation is recommended.

1. This water dispenser is designed for indoor use only
and should not be installed outdoors or in a humid environment. This water dispenser should not be installed on exterior walls.

2. Location planning for remote filter and optional chiller is crucial based on chosen configuration. The location of the water dispenser must be within 15 feet of the remote water filter and chiller (chiller optional). Both must be in an accessible location. For chiller installation, ensure adequate ventilation
space as outlined in chiller manual. It also must be located after the filter for proper filtration and cooling (see figure below).

Water Filter

Water Chiller

Water Dispenser

NOTICE

A water supply pressure below 40 psi will result in decreased

water flow through the unit and damage to the

product. A pressure above 105 psi will also cause

damage to the product.

3. Make sure the water supply pressure to the product is between 40 and 105 psi. The water dispenser with filter requires 40 psi minimum water pressure. The optimum water pressure is 60 psi. The noise level is
lower than 70 dB.

4. Use care when opening and removing the packaging to prevent damage to the product.

a. Inspect the product for any shipping damage and report it immediately to the location of purchase. Installation of a damaged product will void the warranty.

630-574-8484

7

Installation Manual (1000005849 Rev. C – 02/22)

Elkay Manufacturing Company In-Wall Filtered Water Dispenser

LBWD2C00BKC LBWD2C00WHC

b. Refer to part list on page 14 to confirm that all parts have been included for the proper installation of this product. Contact the location of purchase if
damaged parts are found.

NOTICE

Make sure no electrical wiring, potable water inlet pipes, or

drain water outlet pipes will be damaged during

installation of the product. Damage to any of these

items can cause electrical damage, fire, and/or water

damage.

5. Shut off the water supply source and disconnect power to the electrical circuit being used to operate the product before starting the installation.
4. Installation

4.1 Tools Required

Tool Tape Measure Wall Cutting Tool Level Phillips Screw Driver Various Plumber’s Hand Tools 3/32 Allen Wrench

Used For Locate the mounting opening. Remove section of wall to insert unit. Proper mounting into the wall cavity. Remove electrical box cover. Connecting unit’s plumbing to the household water source and waste drain. Remove the front covers.

1/4″ Socket Wrench To release/fix grounding screw

4.2 Parts Required not Included

Description

8 Flathead Screws 1-1/4″ long.

Electrical
IEC 60320 Modular Cord Set with a C13 connector end.
GFCI circuit (connected into an electrical circuit).
All-pole Switch (A disconnection incorporated in the fixed wiring shall be provided, including an all-pole switch with appropriate rating voltage and current connecting with supply mains and the product.)
Water
3/8″ flexible water tubing (copper or plastic) (insulated). Quarter-turn shut off valve at the location of the water source.
1/4″ copper or plastic tubing if a remote filter is installed (insulated)
Optional Catch Basin Drain
1-1/4″ P-trap and related parts.
Plumbers Putty Additional 3/4″ drain hose if the installation requires a longer drain hose than the supplied 13″ long hose.

Qty. 8
1 1 1
— 1 15 feet or less
— — —

4.3 Critical Depth Check 1. Make sure the wall cavity is deep enough to house the
water dispenser (dimension A). Dimension A is a minimum requirement.
A
Water Dispenser A) 3-7/8″ (97 mm) deep.

Elkay Manufacturing Company In-Wall Filtered Water Dispenser

8

630-574-8484

Installation Manual (1000005849 Rev. C – 02/22)

LBWD2C00BKC
4.4 Cutting Size and Mounting Dimensions
A
B
C

LBWD2C00WHC
Note Item 1: If the p-trap is sealed within the wall, under the water dispenser, all the plumbing joints must be glued. The glue must be appropriate for the PVC pipe utilized. If the p-trap uses threaded components, they must be easily accessible.
Note Item 2: According to most electrical codes, the electrical box cannot be sealed inside a wall cavity with no access. If the electrical connection is placed under the unit, a user-supplied removable wall cover will be required to access the junction box.

D
Ground
Recommended Dimensions A – Unit width opening should be 14-1/2″ (368 mm) wide B – Unit height opening should be 19-7/8″ (505 mm) high C – Unit height from the floor is 55-3/4″ (1441 mm) D – Optional cut from bottom of water dispenser to floor for plumbing and electrical access 4.5 Plumbing and Electrical Key

4.6 Water Dispenser Installation
There are various filter and drain installation options available. Once the water dispenser is installed, use the following sections to configure the filter and optional drain line installation using the appropriate configuration:
1. Water dispenser with a remote filter with no chiller. Note: When the filter is located in a remote location, mount the filter vertically on a wall or other supporting structure before the water filler.
2. Water dispenser with remote filter and chiller. Note: When the filter is located in a remote location, mount the filter vertically on a wall or other supporting structure before the water chiller.
3. Water dispenser with optional waste drain.
Regardless of configuration type, follow below instructions to first install the water dispenser, then turn to the selected configuration section to complete installation:
1. Cut the opening into the wall using the recommended mounting dimensions as a guide. See figure 4.4.
2. Place the unit into the wall cavity and slide it up against the drywall at the top of the opening. The unit is designed with 1/4″ overlap to conceal any irregularities at the top of the wall opening.

1 3
2

Ground

Plumbing and Electrical Key 1) P-trap. 2) 3/8″ flexible water tubing. (3) Electrical box.
Note: Always consult local plumbing codes prior to installation.

630-574-8484

9

Installation Manual (1000005849 Rev. C – 02/22)

Elkay Manufacturing Company In-Wall Filtered Water Dispenser

LBWD2C00BKC LBWD2C00WHC
4.7 Installing the Remote Filter The filter unit is installed remotely, up to 15 feet away from the water dispenser. The filter can also be installed in conjunction with a remote chiller. If installing a chiller, first review section 4.8 to ensure proper preparation is taken.
1. Remove the filter head from the packaging box.
A 1/4″ offset helps conceal any irregularities at the top of the wall opening.
3. Using a bubble level, straighten the water dispenser and attach it to the wall studs using four #8 flathead screws.

CAUTION Follow all safety practices and industry regulations and standards when connecting any electrical device. A minimum 15 AMP GFCI Circuit Breaker is required for safe installation.
4. Connect unit to 220-240V, 50/60Hz power source using an IEC 60320 Modular Cord Set with a C13 connector end (Cord Set not provided).
a. Route a C13 connector end through the wall and insert into unit`s C14 power inlet:

2. Securely mount the filter head vertically in the desired remote location within 15ft of water dispenser. One recommendation is to install the filter head by screwing it into a stud on the back side of a wall. a. Remove the short 3/8″ copper inlet water tube. b. Remove the NFC card. c. Remove the four screws that hold the bracket to the filter head.
A c
B
d. Screw the bracket to a wall stud, then reassemble the filter head, NFC card, and inlet water tube.

Elkay Manufacturing Company In-Wall Filtered Water Dispenser

10

630-574-8484

Installation Manual (1000005849 Rev. C – 02/22)

LBWD2C00BKC LBWD2C00WHC

Note: If desired, you can install the filter into the filter head now.
3. Connect a 3/8″ water supply line, copper or plastic, to the quarter-turn shutoff valve at the remote location.
4. Connect a 1/4″ supplier installed insulated copper or plastic, to the outlet connector of the filter.

NOTICE

Do not disconnect the 1/4″ tubing from the water valve at

the top of the water dispenser. This connection has

been factory tested to be leak-free and could result in

water leaking into the unit if this connection is

changed.

6. Connect the extension cable (18 foot NFC wire) from the NFC card circuit board to the wire harness on the water dispenser circuit board.

7. Mark the current date on the water filter label.

8. Place the filter into filter head with the label facing outward.

9. Firmly press the filter into the filter head and turn it clockwise (install).

Note: When a filter requires replacement, a red indicator light illuminates on the bottle filler. If the new filter is installed and red indicator light is still ON the filter has been installed incorrectly. The filter can only be installed in one direction (label facing outward). If the red indicator light is ON, the filter is installed backwards.

Note: Elkay branded filter must be installed for indicator lights to function properly.

5. Connect the 1/4″ insulated water line to either a
remote chiller (if used) or the 1/4″ water line on
the bottle filler. Use a union connection fitting to connect the water line to the bottle filler. The type of 1/4″ tubing, copper or plastic, should meet all local regulations and building codes. This line should be insulated to prevent condensation.

630-574-8484

11

Installation Manual (1000005849 Rev. C – 02/22)

Elkay Manufacturing Company In-Wall Filtered Water Dispenser

LBWD2C00BKC LBWD2C00WHC

4.8 Installing with Remote Water Chiller (optional)
A remote water chiller can be installed in connection with the water dispenser to supply chilled water. The chiller must be installed within 15 feet of the water dispenser, in an accessible location. Install the chiller with adequate ventilation space, as outlined in the water chiller manual.

The standard installation of the in-wall water dispenser supplies filtered water at the ambient temperature of the water supply that comes into the unit. This temperature can vary greatly depending on the location of the incoming water line.
Follow the installation instructions that come with the water chiller. The water dispenser and filter must be installed prior to the chiller, and the water line from the chiller to the water dispenser cannot be more than 15 feet long. When the filter is located in a remote location, mount the filter vertically on a wall or other supporting structure near the chiller.
NOTICE The filter must be installed before the chiller to function properly. The filter will have water stored within it, so if the filter is after the chiller, the unit will dispense ambient water for 1-2 cycles before receiving chilled water.

2. Place the drain basin on a flat, hard surface, such as a piece of sacrificial wood. Carefully drill a hole in the basin using a 1″ hole saw using the centering-dimple as a guide to center the hole saw.
Note: Do not use a 1-1/8″ hole saw as this will make the opening too large.

Water Filter

Water Chiller

Water Dispenser

3. Trial fit the strainer. If the strainer does not fit, carefully open the size of the hole. If it fits well, place a small amount of plumbers putty around the lip of the strainer flange and insert it into the hole.

Note: The remote chiller can take from 24 to 48 hours to provide completely chilled water. Water lines must be insulated to prevent condensation.
4.9 Connecting Catch Basin Drain (optional)
The water dispenser does not require a drain connection to the wastewater plumbing. The water dispenser has a built-in catch basin that will hold the typical overflow that can occur when using the product.
Some local building codes, however, may require a wastewater drain to prevent the potential overflow of water. The following steps cover the installation of the drain.
1. Remove the two screws attaching the drain basin to the water dispenser. Remove the drain basin.

4. Install the O-ring over the strainer threads.

Elkay Manufacturing Company In-Wall Filtered Water Dispenser

12

630-574-8484

Installation Manual (1000005849 Rev. C – 02/22)

LBWD2C00BKC

LBWD2C00WHC
7. Place the drain basin back into the water dispenser and reinstall the two screws.

5. Thread the strainer into the drain adapter. Needle-nose pliers can be used to hold the drain adapter from the top while tightening. Ensure that the connection creates a watertight seal. The drain adapter must be facing to the left.
Note: Twisting the strainer instead of the drain adapter can compromise the seal created by the plumber’s putty.

8. Attach the other end to the p-trap drain adapter using
a hose clamp. The drain adapter is designed to be glued into a 1-1/4″ PVC pipe.

` NOTICE

For the following steps, it is recommended to use a heat

gun when manipulating the flexible drain hose. It is

beneficial to conservatively soften the material

before trying to make connections.

6. Attach one end of the 3/4″ flexible drain hose to the 3/4″ barbed drain adapter connection using the supplied hose clamp. The supplied flexible drain is 13″ long. If a longer drain hose is required, it must be installer- supplied.

9. Connect the drain adapter into the waste drain pipe.
If the p-trap is located inside a sealed walled, it must have permanently- glued joints. If the p-trap is in an accessible location, a standard non-glued p-trap is acceptable.
Note: Whichever installation method is used: it must meet local standards and building codes.
10. Install the metal cover. Do not install the drip tray if the unit is plumbed into the local waste line.

630-574-8484

13

Installation Manual (1000005849 Rev. C – 02/22)

Elkay Manufacturing Company In-Wall Filtered Water Dispenser

LBWD2C00BKC LBWD2C00WHC

5. Startup

1. Open the shutoff valve(s) for the water supply. Check for any water leaks.
2. Remove the scratch-resistant protective layer that is covering the glass face, and the back wall of the water dispenser.
Note: Not removing the back wall covering layer will activate the IR sensor when the unit is turned ON.
3. Place the ON/OFF switch in the upper left-hand corner of the water dispenser opening in the OFF position. Turn the power to the unit ON (typically a circuit breaker).

6. If there are no leaks and the unit is functioning correctly, install the water dispenser’s glass front cover using the flathead screws and a 3/32″ hex wrench.
7. Upon initial startup, the PLASTIC BOTTLES SAVED indicator panel should show several bottles have been saved due to the water used to initially start up the unit.
8. The left-most FILTER LIFE indicator light should also be lit. This light shows the filter is functioning correctly and has used less than 65 percent of its capacity.
When the middle blue light illuminates, the filter has reached 66 percent of its life and will need to be changed soon. When this indicator light comes on, a replacement filter should be ordered.
9. The right-most light will illuminate in red and indicates that the filter should be changed.

FILTER LIFE PLASTIC BOTTLES SAVED

4. Move the power switch to the ON position and make sure the LED lights are lit.
5. Place a container under the water dispenser spout to activate the fill sensor and dispense at least one gallon of water to bleed off any trapped air from the supply lines and filter as well as flush any fine carbon particles from the filter.

10. Once the installation is complete, the water has been turned on, and any trapped air has been bled from the system re-check for any water leaks.
11. Enjoy fresh filtered water with your new Elkay ezH2O Liv Water Dispenser!

Note: The water dispenser is set to automatically shut
off after 16 ounces or 12 seconds of water has been dispensed to prevent overflow and potential flooding so multiple activations will be required to get the required one gallon of water flow through the unit.

Elkay Manufacturing Company

14

In-Wall Filtered Water Dispenser

630-574-8484 Installation Manual (1000005849 Rev. C – 02/22)

LBWD2C00BKC LBWD2C00WHC

Replacement Parts List

ITEM PART NO. NO.

DESCRIPTION

NS 1000004698 Fitting – Hose to Trap

1 1000005930 KIT – Solenoid (220V)

2 1000005396 LED Bezel, KIT – Harness

3 1000004711 Wire – 18′ NFC, Remote Filter Connection

4 1000005939 Alcove, KIT – Alcove

5 1000005392 KIT – Drain Basin

6 1000005846 Switch – Rocker LIV

7 1000005393 Lens, KIT – IR

8 56331C

Connector

9 70793C

Elbow 1/4 O.D. X 90

NS ECF3000 3,000 Gal Filter

10 1000005454 KIT – Filter Head and Bracket Assembly

NS 1000005347 KIT – Replacement Glass – Black

NS 1000005348 KIT – Replacement Glass – White

11 1000001812 KIT – Bottle Filler Drain

12 1000005940 KIT – Control Board (220V)

13 1000005395 KIT – NFC Reader

NS = NOT SHOWN

MAIN ENCLOSURE ASSEMBLY
ALCOVE ASSEMBLY

Fig. 1

4

9

8

1 12

6 4

4
4 4
I.R SENSOR ASSEMBLY

7

NOTE: Rear view shown with panel cut section
Rear View of Water Dispenser Fig. 2

630-574-8484

15

Installation Manual (1000005849 Rev. C – 02/22)

5 5
5
11 11 Alcove Assembly Fig. 3
Elkay Manufacturing Company In-Wall Filtered Water Dispenser

LBWD2C00BKC LBWD2C00WHC
10 13
Filter Head Assembly Fig. 4

Elkay Manufacturing Company In-Wall Filtered Water Dispenser

Electrical Diagram Fig. 5

16

630-574-8484

Installation Manual (1000005849 Rev. C – 02/22)

LBWD2C00BKC LBWD2C00WHC 6. Troubleshooting

Description Water is not getting cold. Water runs continuously from water dispenser.
Low water flow.
No water flow.
Blinking red light. Blinking red and blue light.

Possible Cause Standard water dispenser (nonchilled) Water chiller is not operating properly. Sensor is defective or dirty. Solenoid or solenoid diaphragm is defective.
Supply water pressure is less than required. Filter is plugged. Solenoid water valve not opening fully. No electrical power. Water shut-off valve(s) closed.
Bottle sensor is not operating properly. Blocked or damaged water line. No filter. Filter incorrectly installed. Filter wire disconnected.

Remedy Standard unit only supplies ambient temperature water.
Refer to water chiller manual.
Clean or replace sensor. Replace solenoid water valve. Note: To verify faulty solenoid, disconnect the power
while water is running. If water flow does not stop immediately then replace the solenoid. Water pressure must be between 40 and 105 psi.
Replace filter. Replace solenoid water valve.
Restore power to the unit. Open all shut-off valves (one is located inside the filter box if installed and another may be at the water source). Sensor is malfunctioning and must be replaced.
Locate affected line and remove blockage or damage. Replace filter. Check filter is completely installed. Check filter cable connections.

630-574-8484

17

Installation Manual (1000005849 Rev. C – 02/22)

Elkay Manufacturing Company In-Wall Filtered Water Dispenser

Notes

LBWD2C00BKC LBWD2C00WHC

Elkay Manufacturing Company In-Wall Filtered Water Dispenser

18

630-574-8484

Installation Manual (1000005849 Rev. C – 02/22)

LBWD2C00BKC LBWD2C00WHC

630-574-8484

19

Installation Manual (1000005849 Rev. C – 02/22)

Elkay Manufacturing Company In-Wall Filtered Water Dispenser

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

ELKAY User Manuals

Related Manuals