tyco PG4914 DSC PowerG Wireless Digital Pet-Immune PIR Motion Detector Installation Guide
- June 9, 2024
- tyco
Table of Contents
- tyco PG4914 DSC PowerG Wireless Digital Pet-Immune PIR Motion Detector
- Features
- INSTALLATION
- Configuring the detector parameters
- LOCAL DIAGNOSTICS TEST
- TROUBLESHOOTING
- COMPLIANCE WITH STANDARDS
- FCC
- Special comments
- SPECIFICATIONS
- Limited warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
tyco PG4914 DSC PowerG Wireless Digital Pet-Immune PIR Motion Detector
Features
The PGx914 (pet immune) is a microprocessor-controlled wireless digital PIR
detector supported by DSC alarm systems using PowerG two-way communication
protocol.
The detector’s features are as follows:
- Fresnel and cylindrical lenses with uniform detection sensitivity throughout its operating range, up to 12 meters (39 ft).
- Target Specific Imaging™ (TSI) technology is used for distinction between humans and pets weighing up to 38 kg (85lb).
- The advanced True Motion Recognition™ algorithm (patented) distinguishes between the true motion of an intruder and any other disturbances which may cause false alarms.
- No vertical adjustment is needed.
- Motion event counter determines whether 1 or 2 consecutive motion events trigger an alarm.
- Very low current consumption.
- Microprocessor-controlled temperature compensation. Sealed black chamber provides white light protection.
- Front and back tamper protection.
- The device supports temperature and light level reports to compatible alarm systems that support temperature and light sensors.
For UL installations: The detector is for use with UL listed control units only. Pet immunity has not been evaluated by UL.
- A. Enroll button
- B. Light sensor
- C. LEDs
- D. Tamper switch
- E. PIR sensor
INSTALLATION
General Guidance
- Keep away from heat sources.
- Do not expose to air drafts.
- Do not install outdoors.
- Avoid direct sunshine.
- Do not install near high-voltage electrical lines.
- Do not install behind partitions.
- Mount on a solid stable surface.
Warning! Do not partially or completely obscure the detector’s field of view.
Installation procedure
- A: Surface mount
- B: Corner mount, B1 or B2
- C: Back tamper
- D: Cover
- E: Base
- F: Press in point
- Mount the bracket on the wall.
- Press in the point marked “F” in the drawing and separate the cover from the base.
- Insert the battery while observing polarity alternatively, if battery is already installed, remove the activation strip that protrudes from the front of the detector.
- Return the cover to the base until a click is heard (the snap is closed).
- Secure the detector with the screw.
- Align the detector with the bracket.
- Slide the detector upward until a click is heard.
Note: The detector transmits a low battery signal upon detection of low
voltage. It is recommended to wait about 1 minute after battery removal,
before inserting the new battery.
Note: Install the pet mask if you require pet immunity. See Installing
the Pet Mask.
PGx914 shall be installed in accordance with the Standard for Installation and
Classification of Burglar and Holdup Alarm Systems, UL 681. Caution! Risk of
explosion if battery is replaced by an incorrect type. Dispose of used battery
according to the manufacturer’s instructions.
Installing the pet mask
Install the plastic (pet mask) if you require pet immunity.
- Insert the tabs at the base of the pet mask into the holes below the PIR sensor.
- Align the tabs on the sides of the pet mask with the holes on either side of the PIR sensor.
- Press down gently to install the pet mask.
Note: Pet immunity is not supported at heights of 2.4 m (7.87 ft) and
above. Do not install the pet mask if you are mounting the MP-802 K9-85 PG2 at
this height or above.
Removing the pet mask
Remove the plastic pet mask if you do not require pet immunity.
- Place your thumb at the base of the Pet Mask.
- Place your fingers at the top of the Pet Mask.
- Lift the Pet Mask to remove.
Disassembly from bracket
- Release screw.
- Separate the cover from the base.
- Remove battery.
- Press on the stopper snap to release the base from the bracket.
- Slide the base downward to remove.
Enrollment
See the alarm systems Installation Guide and follow the enrollment procedure.
A general description of the procedure is provided in the following flow
chart.
Step Procedure
- See the Installation Manual for the alarm system that the device is being enrolled on, to ensure that the proper steps are used.
- Enter the Device Enrollment option through the specified method and select the appropriate option to add a new device.
- Enroll the device by either holding the enroll button until the enrollment is detected, or by entering the Device ID.
- Select the desired Zone Number.
- Configure any device parameters that are required.
- Mount and test the detector. See section 3 for information on testing the device. In addition, see the alarm systems Installation Manual that the device is enrolled on for other test procedures that are required.
Note: If the detector is already enrolled, you can configure the detector parameters by programming the system, see the alarm systems Installation Manual for more information about device parameters.
Temperature display
For instructions on displaying the temperature of zones on the control
panel as measured by PGx914 detectors, see the alarm systems Installation
Manual for details.
Configuring the detector parameters
Enter the DEVICE SETTINGS menu and follow the configuration instructions for the PGx914 detector as described in the following table.
Option | Configuring Instructions |
---|---|
Alarm LED | Define whether or not the alarm LED indication will be activated. |
Optional settings: LED ON (default) and LED OFF.
Event Counter| Define whether an alarm will be activated upon continued motion
(low sensitivity) or upon a single alarm event (high sensitivity). Optional
settings: LOW sensitivity (default) and HIGH sensitivity.
High Traffic Shutdown| Define whether or not the sensor is active when the
system is disarmed. Optional settings: NOT Active while disarmed (default), –
no delay, 5s delay, 15s delay, 30s delay, 1m delay, 2m delay, 5m delay, 10m
delay, 20m delay and 60m delay.
LOCAL DIAGNOSTICS TEST
Note: Run a diagnostic test at least once a week to ensure that the detector is working correctly.
- Separate the base from the cover.
- Replace the cover to return the tamper switch to its normal (undisturbed) position, and then secure the front cover to the base with the case closure screw.
- The PGx914 detector will enter a 2 min. stability period. During this time the red LED blinks.
- Walk-test the coverage area.Walk across the far end of the coverage pattern in both directions. The red LED lights each time your motion is detected followed by 3 LED blinks.
Important! Instruct the user to walk test at least once a week to verify proper functioning of the detector. The following table outlines received signal strength indication:
LED response | Reception |
---|---|
Green LED blinks | Strong |
Orange LED blinks | Good |
Red LED blinks | Poor |
No blinks | No communication |
Important! Reliable reception must be assured. Therefore, poor signal
strength is not acceptable. If you receive a poor signal from the device,
relocate it and re-test until a good or strong signal strength is received.
For UL/ULC installations, only STRONG signal level are acceptable. After
installation verify the product functionality with the compatible receivers
HSM2HOST9, HS2LCDRF (P)9, HS2ICNRF(P) 9, PG9920 and WS900- 29, WS900-19.
Note: For detailed placement instructions see the alarm systems
Installation Manual.
TROUBLESHOOTING
If you encounter one of the following problems with the PGx914, perform the suggested solution from the following table:
Problem | Solution |
---|---|
Attempt to enroll the sensor is unsuccessful. | Ensure that the detector is |
within wireless communication range of the receiver. Ensure that the enroll
button on the device is held until the LED flash is seen, and then released.
The sensor and the panel do not communicate.| Perform a placement test as
described in the alarm systems Installation Manual. Ensure that the device is
within wireless communication range of the receiver and remove any possible
sources of interference. If necessary, replace the sensor’s battery.
The sensor sends a low battery indication.| To ensure continuous proper
operation, replace the battery within two weeks of the first low battery
indication.
Panel does not arm because of a sensor malfunction.| Follow the diagnostic
test procedure from Section 3 above to test the detector. Replace the battery
if flashing LEDs are not seen during this test. If the system still cannot be
armed, consult with your alarm system technician for a solution.
COMPLIANCE WITH STANDARDS
The PG8914 model complies with the following standards:
Europe: EN 300220, EN 301489, EN 62368-1, EN 50130-4, EN 50131-1, EN
50131-2-2 Grade 2 Class II, EN 50130-5, EN 50131-6 Type C
UK: The PG8914 model is suitable for use in systems installed to conform
to PD6662 at Grade 2 and environmental CLASS II. BS8243 Certified by Applica
Test & Certification AS in accordance with EN 50131-2-2, EN 50131-5-3, EN
50131-6, EN 50130-4, EN 50130-5
Applica T & C has certified only the 868 MHz variant of this product.
SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, Tyco Safety Products Canada Ltd declares that this radio equipment is
in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available for the models
mentioned below are available at the following Internet addresses:
- PG4914: www.dsc.com/pdf/1707007
- PG8914: www.dsc.com/pdf/1707008
Euopean single point of contact:
Tyco Safety Products, Voltaweg 20, 6101 XK Echt, Netherlands
UL/ULC Notes
Only model PG9914 operating in the frequency band 912- 919MHz is UL/cUL
listed. The PG9914 has been listed by UL for commercial and residential
burglary applications and by ULC for residential burglary applications in
accordance with the requirements in the Standards UL 639 and ULC-S306 for
Intrusion Detection Units.
For UL/cUL installations use this device only in conjunction with compatible
DSC wireless receivers: HSM2HOST9, HS2LCD HS2ICNRF(P)9, PG9920 and WS900-29,
WS900-19. After installation verify the product functionality in conjunction
with the compatible receiver used.
FCC
This device complies with Part 15 of the FCC Rules and RSS-247 of ISED.
Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation
WARNING! Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
To comply with FCC and IC RF exposure compliance requirements, the device
should be located at a distance of at least 20 cm from all persons during
normal operation. The antennas used for this product must not be co-located or
operated in conjunction with any other antenna or transmitter.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
W.E.E.E. Product Recycling Declaration
For information regarding the recycling of this product you must contact
the company from which you originally purchased it. If you are discarding this
product and not returning it for repair then you must ensure that it is
returned as identified by your supplier. This product is not to be thrown away
with everyday waste.
Directive 2012/19/EC Waste Electrical and Electronic Equipment.
Special comments
Even the most sophisticated detectors can sometimes be defeated or may fail to
warn because of DC power failure or improper connection, malicious masking of
the lens, tampering with the optical system, decreased sensitivity in ambient
temperatures close to that of the human body and unexpected failure of a
component part.
The above list includes the most common reasons for failure to detect
intrusion but is by no means comprehensive. It is recommended that the
detector and the entire alarm system be checked weekly, to ensure proper
performance. An alarm system must not be regarded as a substitute for
insurance. Property owners or renters should be prudent to continue insuring
their property, even though they are protected by an alarm system
SPECIFICATIONS
COMPATIBLE RECEIVERS
Note: Only devices operating in band 912-919 MHz are UL/ULC listed.
Limited warranty
Digital Security Controls warrants that for a period of 12 months from the
date of purchase, the product shall be free of defects in materials and
workmanship under normal use and that in fulfillment of any breach of such
warranty, Digital Security Controls shall, at its option, repair or replace
the defective equipment upon return of the equipment to its repair depot. This
warranty applies only to defects in parts and workmanship and not to damage
incurred in shipping or handling, or damage due to causes beyond the control
of Digital Security Controls such as lightning, excessive voltage, mechanical
shock, water damage, or damage arising out of abuse, alteration or improper
application of the equipment. The foregoing warranty shall apply only to the
original buyer and is and shall be in lieu of any and all other warranties,
whether expressed or implied and of all other obligations or liabilities on
the part of Digital Security Controls. Digital Security Controls neither
assumes, nor authorizes any other person purporting to act on its behalf to
modify or to change this warranty, nor to assume for it any other warranty or
liability concerning this product. In no event shall Digital Security Controls
be liable for any direct, indirect or consequential damages, loss of
anticipated profits, loss of time or any other losses incurred by the buyer in
connection with the purchase, installation or operation or failure of this
product. Motion detectors can only detect motion within the designated areas
volumetric area protection. They have multiple beams of detection and motion
can only be detected in unobstructed areas covered by these beams. They cannot
detect motion that occurs behind walls, ceilings, floor, closed doors, glass
partitions, glass doors or windows. Any type of tampering whether intentional
or unintentional such as masking, painting, or spraying of any material on the
lenses, mirrors, windows or any other part of the detection system will impair
its proper operation.
Passive infrared motion detectors operate by sensing changes in temperature.
However their effectiveness can be reduced when the ambient temperature rises
near or above body temperature or if there are intentional or unintentional
sources of heat in or near the detection area. Some of these heat sources
could be heaters, radiators, stoves, barbeques, fireplaces, sunlight, steam
vents, lighting and so on.
WARNING: Digital Security Controls recommends that the entire system be
completely tested on a regular basis. However, despite frequent testing, and
due to, but not limited to, criminal tampering or electrical disruption, it is
possible for this product to fail to perform as expected.
Important Information: Changes or modifications not expressly approved by
Digital Security Controls could void the user’s authority to operate this
equipment.
© 2021 Tyco Security Products. All Rights Reserved.
www.dsc.com
The trademarks, logos, and service marks displayed on this document are
registered in the United States [or other countries]. Any misuse of the
trademarks is strictly prohibited and Tyco will aggressively enforce its
intellectual property rights to the fullest extent of the law, including
pursuit of criminal prosecution wherever necessary. All trademarks not owned
by Tyco are the property of their respective owners, and are used with
permission or allowed under applicable laws. Product offerings and
specifications are subject to change without notice. Actual products may vary
from photos. Not all products include all features.
Availability varies by region; contact your sales representative.
© 2021 Tyco International Ltd. and its Respective Companies.
All Rights Reserved. Tech Support:
1-800-387-3630 (Canada & U.S.) or
+800-2255-8926 Printed in Israel • www.dsc.com
References
- DSC
- dsc.com/pdf/1707007
- dsc.com/pdf/1707008
- Accueil campagne NF - NF
- Wireless Security - Wireless Home Security Products and Systems | Visonic
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>