DIGITAL YACHT WND100 Wind Transducer Instruction Manual
- June 4, 2024
- DIGITAL YACHT
Table of Contents
DIGITAL YACHT WND100 Wind Transducer
Introduction
Congratulations on the purchase of your WND100 Wind Transducer. It is
recommended that this product is installed by a professional, marine
electronics engineer.
Installation of the Wind Transducer should only be conducted when the mast is
down.
Before you start
You will need the following items and tools to complete the installation;
- The WND100 Transducer with 20m Cable (supplied)
- A 1A inline fuse
- 3x Suitable M5 Nut and Bolts or No10 Self Tapping Screws to fix the transducer to the top of the mast
- A suitable waterproof deck gland for the cable to pass through
To display the wind data, you will need a suitably compatible device with an NMEA0183 data input at 4800 baud.
Installation
The WND100 Wind Transducer should be mounted so as to position its sensing
parts, the cups and the vane, that they are always directly in the wind in
whatever direction it is coming from. In a boat, the best place is high and
forward of the mast. In fixed installations, the unit should be clear of a
roof or similar obstructions, by at least half a meter.
It is very important that the WND100 is mounted parallel to the center line of
the boat. It is possible to calibrate the WND100 to remove any angular offset
that might be introduced during installation, but if you can accurately
position the transducer with the main shaft facing forward, parallel to the
boat’s centre line, then this will ensure the best performance and accuracy.
Using the cable base as a template, spot mark through the fixing holes to the
mast cap. The cable should run aft, with the single screw forward. Use
stainless steel screws to fix the cap, (either No10 self-tapping screws, or M5
machine screws).
The WND100 can then be fitted to the base with the two screws provided. The
20m cable of the WND100 is terminated with bare ended wires.
Electrical Wiring
The WND100 is designed to work from a DC supply with a voltage range of 8V to
30V and typically consumes about 15mA (0.015A). To protect the wiring, it is
recommended that an inline fuse of 1A is fitted to the Red (Power+) wire of
the WND100 cable. This is not necessary when connecting it to our WindSense
wireless interface, which has internal self-resetting fuses for the WND100.
Primarily the WND100 is designed to be used with Digital Yacht’s wireless
WindSense product (see WindSense Quick Start Guide for more information) but
it can also be used in a number of different applications, such as; replacing
an existing wind transducer that has failed, providing a Wind Input to a
Mutli-Function Display (MFD) or getting Wind data on to a Personal Computer.
The WND100 uses an industry standard NMEA0183 interface to communicate wind
data to other equipment. To reduce the number of connections, the NMEA0183
signals are not true differential inputs and outputs. When connecting the
WND100 to an NMEA0183 device that has a differential input, the device’s
negative Input should be connected to the Shield wire of the WND100 (as shown
below).
The WND100 can be directly connected to a personal computer if the computer has an old 9 way D-Type RS232 serial COM Port as per this diagram.
For newer personal computers that only have USB ports, you will need to use a Digital Yacht USB to NMEA converter (P/No ZDIGUSBNMEA). This creates a virtual COM port on your PC that navigation software can use to read the NMEA0183 wind data.
The diagram below shows the bi-directional connection between the WND100 and our USB to NMEA converter.
Once the WND100 is wired up to whichever equipment it is to be used with, apply power, ensure the equipment is set to receive NMEA0183 Wind Data at 4800baud and check that it is receiving valid Wind data.
Technical Specification
-
Protocols
NMEA-0183 Version 3.01 -
NMEA Sentences
MWV (5Hz) -
Update Rate
5Hz by default (configurable up to 10Hz) -
Maximum Velocity
80 knots -
Minimum Velocity
1.7 knots -
Wind Speed (WS) Resolution
0.1 knot -
Wind Angle (WA) Resolution
0.1º -
Typical (Max) WS Error
3% (5%) -
Typical (Max) WA Error
4º (8º) -
Operating Temperature
25°C to +50°C degrees Celsius -
StorageTemperature
– 40°C to +100°C degrees -
Maximum Current
15mA (@12Volts) -
Power Input
VDC +8v to 30v -
Cable
Black 20m Shielded Cable (4.75mm OD)