eSSL-HG-1500 Sliding Gate User Manual

June 4, 2024
eSSL

eSSL-HG-1500 Sliding Gate User Manual
eSSL-HG-1500 Sliding Gate

Warning To The Installer And USer

  1. CAUTION! For personal safety it is important to follow all the instructions carefully. Incorrect installation or misuse ofthe product may cause serious harm to people .
  2. Keep the instructions in a safe place for future reference.
  3. This product was designed and manufactured strictly for the use indicated in this document. Any other usage not expressly indicated in this Document, may damage the product and/or be a source of danger.
  4. BS accepts no responsibility due to improper use of the automatic machine ( opener) or use other than that intended.
  5. Do not install the machine in an area subject to explosion hazard.Inflam-mable gasses or fumes are a serious safety hazard.
  6. BS will not accept responsibility if the rules of good workmanship are disregarded in installig the closing elements to be motorised, if any deformation occurs during use of the said elements.
  7. Before carrying out any work on the system, turn off the electricity supply.
  8. The safety devices(e.g.photocells,sensitive edges, etc…) may be used to prevent any potential risk in dangerous areas where the moving mechanism is located , such as crushing, dragging, or shearing.
  9. BS accepts no responsibility regarding safety and correct operation of the machine, should components made by manufacturers other than we be used in the system.
  10. Do not make any alterations to the components of the automatic mach-ine ( opener and accessory).
  11. The installer must supply full information regarding operation manual of the system in the event of any emergency and provide the system user with the “INSTRUCTION” included with the product.
  12. Do not allow children or other people to stand near any moving part of the opener or door construction while in operation.
  13. Keep transmitters away from children to prevent the machine from being activated accidentally.
  14. The user must refrain from attempting to repair or adjust the system perso-nally and should only contact professional personnel .
  15. Frequently examine the installation, in particular check cables, springs and mountings for signs of wear, damage or imbalance .Do not use if repair or adjustment is needed since a fault in installation or an incorrectly balanced door may cause injury.
  16. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  17. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  18. Disconnect the supply when cleaning or other maintenance is being carried out, if the appliance is automatically controlled.
  19. The temperature range marked on the drive should be suitable for the location.
  20. The electrical cord plug must plug in indoor outlet or waterproof cover outle.

Introduction

BS-IZ-I Complete kit
  • Release key

  • Limit stopper

  • Transmitters

  • Base plate

  • Accessories

  • BS-IZ-I
    BS-IZ-I

BS-IZ-II Complete kit
  • Release key

  • Limit magnet/ Bracket

  • Transmitters

  • Base plate

  • Accessories

  • BS-IZ-II
    BS-IZ-I

Dimension

Dimension

  • Built-in control board.
  • Terminals for Push button, Photocell, Alarm lamp.
  • Auto-closing is available, time delay is adjustable

Technical Specifications

Model| BS — I Z 1000
BS — I Z 1500
---|---
Power supply| 220V/50Hz or l10V/60Hz
Motor power| 370W 450W
Absorbed current| 3A
Motor rotational speed| l400r/min
Thermal protection on motor winding| 120″C
Ambient temperature| 20″C 55’C
Max weight of gate| 1000kg 1500kg

Installation

  • Before using the machine, check power supply, grounding, voltage, etc.
  • Check whether it is connected according to the demand of wiring diagram.
  • The gate should be pulled easily and smoothly manually when the worm gears are released .
  • The worm gears will be coupled before power on.
  • The product must be installed by professional person.
Example ol a sliding gate operator installed

Installation instruction

Installation and adjustment

Install baseplate on the ground, then, fasten the sliding motor on the baseplate.
Key: Ensure baseplate on level position.
Installation and adjustment

Install the limit stopper or limit magnet at proper position on the

steel rack

Installation instruction
Installation instruction

Before place the limit stoper or magnet on the rack, the gear box of the operator must be released. As per Fig 6A or fig 6B, Use the key turn clockwise to release the gear.

Installation instruction

Move the gate manually to the open limit and close limit, mark the points on the Rack, then, fix the limit Stoppers or Magnets at the limit points on the Rack.

When the Operator is installed on Left Side
Operator is installation

When the Operator is installed on Right Side
Operator is installation

NOTE: Magnet must be 10mm 20mm space from the operator, and must be same height with the Magnetic switch inside of the Operator.

Control Board

Layout of PSDB and Definition
  1. PI: Set running time
  2. P2: Set auto-Closing delay time
  3. SI: Set transmitter
  4. LED1: Set transmitter LED
  5. LED2: Running state LED
  6. LED3: Open limit LED
  7. LED4: Close limit LED
  8. LED5: Power LED
  9. VR1: Adjust power of motor
  10. VR2: Adjust resistance of obstacle
  11. 13: Termingl for Antenna
  12. 14: Jumper for reverse function (ON: valid)
  13. F1: Fuse for transformer (0.2A)
  14. F2: Fuse for motor ( l0A)
  15. S4: DIP switch for function choice
    Control Board
Diagram

Diagram

Set running time

After finish the installing and connecting, Power on, and Press “P 9 “for 3 second, the gate will open and close at the limit point one cycle, the running time isremembered by the control system.
If no limit stopper or limit magnet on the rack, you also can press “P 8 ” when the gate open and close to the right limit points.
Set running time

Set Auto-closing delay time

When the motor is stand-by, Press “PM” for 3 second, LED2 lighten, time- counter starts, then Press “BE” again after the need delay time. LED2 is out , delay time is set.
Delay time

Set Reverse fuzsctiozs

Try to adjust VR2 again and again till the sensitivity is exact to reverse when the running gate meets obstacle.

DIP switch programming
  • DIP1:
  • ON: Auto-closing is valid
  • OFF: Auto-closing is invalid
  • DIP2:
  • ON: When the gate is running to close, press button on transmitter, the gate open immediately
  • OFF: Single button control and “Step-by-Step” mode carry out “Open-Stop-Close-Stop-Open”
  • DIP3:
  • ON: soft stop
  • OFF: No Soft stop
  • DIP4:
  • ON: soft start
  • OFF: No Soft start
Transmitter’s code setting

Press “LEARN BUTTON”,the “LEARN LED” light, then, press the button which you choose on the transmitter till the “LEARN LED ” flash and go out, Now, the transmitter is coded. Other transmitters can be coded as this way Specification maybe changed without a prior notification.

Erasing the transmitter’s code

Erasing transmitter codes: Press” LEARN BUTTON”and hold on to make the”LEARN LED”1ight till go out. Now, all codes of transmitters which had been learnt are cleared.

Troubleshooting

  Trouble Cause Shooting
1 motor can not work
  • No power supply *Break ftise
  • capacitor decay
  • Surpass load
  • Effecteâ by the thermal protection

|

  • Check if any barrier on track ‘Restart after 20 minutes

2| Can open (close) but can not close (open)|

  • Position of limit switch is not correct
  • Limit switch is éamageé
  • vtet#ei L1\C0M\L2 wires are connected wrong
  • Magnetic-steel dropped and position isn’t right

|

  • Adjust position ‘Change linit switch
  • Connect correctly according to virirg diagram ‘Re- aéjcst magnetic-steel position

3| can not locate accurately|

  • Distance of limit switch is too large limit switch is
  • whether COM. CLOSE, OPEN were connected
  • magnetic-steel’ s position is wrong

|

  • Adjust position of limit switch
  • Change limit switch
  • Connect correctly according to wiring diagram
  • Re-adjust the position

4| Release device|

  • Operating handle is broken
  • Worm gears are jammed

|

  • Change the handle
  • Rotate the pinion

5| Push the “open” button but the  gate close|

  • whether LI\L2wires are connected wrong

|

  • Connect correctly according to wiring diagram

6| Motor canturn but can not work|

  • compression spring of clutch is dead
  • Gear box is released

|

  • Change the spring
  • Couple the worm gear

Contact Us

24, Shambavi Building, 23rd Main, Marenahalli, JP Nagar 2nd Phase, Bengaluru

– 560078
Phone : 91-8026090500
Email : sales@esslsecurity.com
www.esslsecurity.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals