Description
The device Is a standalone access control and proximity card reader which supports EM & MF card types. It builds in STC microprocessor, with strong anti-interference ability, high security and reliability, powerful function, and convenient operation. It’s widely used in high-end buildings, residential communities, and other public places.
Features
Ultra-low Power | Standby current is less than 30mA |
---|---|
Wiegand Interface | WG26 or WG34 input and output |
Searching time | Less than 0.1s after reading the card |
Backlight keypad | Operate easily at night |
Doorbell interface | Support external wired doorbell |
Access ways | Card, Pin code, Card & Pin code |
Independent codes | Use codes without related card |
Change codes | Users can change codes by themselves |
Delete users by card No. | The lost card can be deleted by the keyboard |
Specifications
Working Voltage: DC12-24V | Standby Current: 30mA |
---|---|
Card Reading Distance: 2 — 5cm | Capacity: 2000 users |
Working Temperature: -40°C —60°C | Working Humidity: 10%-90% |
Lock output load: 3A | Door Relay time: 0-99S (Adjustable) |
Installation
Drill a hole according to the size of the device and fix the back shell with the equipped screw. Thread the cable through the cable hole. connect the wires according to your required function, and wrap the unused wires to avoid short circuits. After connecting the wire, install the machine. (as shown below)
Wiring
Color | ID | Description |
---|---|---|
Green | DO | Wiegand Input(Wiegand Output in Card Reader Mode) |
White | D1 | Wiegand Input(Wiegand Output in Card Reader Mode) |
Yellow | OPEN | Exit Button input terminal |
Red | +12V | 12V + DC Regulated Power Input |
Black | GND | 12V – DC Regulated Power Input |
Blue | NO | Relay normally-on terminal |
Purple | COM | Relay Public terminal |
Orange | NC | Relay normally-off terminal |
Pink | BELL A | Doorbell button one terminal |
Pink | BELL B | Doorbell button to the other terminal |
Diagram
Common Power Supply
Special Power Supply
Reader Mode
Sound & Light indication
Operate Status | LED Light Color | Buzzer |
---|---|---|
Standby | Red | |
Keypad | Beep | |
Operation Successful | Green |
Beep —
Operation Failed| | Beep-Beep-Beep
Entering into Programming| Flash Red Slowly|
Beep —
Programmable Status| Orange|
Exit Programming| Red|
Beep —
Door Opening| Green| Beep-
Advance setting
Master Card Operation
Add Card
Read master add a card
Read master add a card
Read the 1st user card
Read the 2nd user card
Note: The master add card is used to add card users continuously and
quickly.
When you read the master add card for the first time, you will hear a short
“BEEP” sound twice and the Indicator light tums orange, it means you have
entered Into add user programming. When you read the master add a card for the
second time, you will hear a long “BEEP” sound once and the Indicator light
tums red, which means you have exited the add user programming.
Delete Card
Read master delete card
Read the Pt user card
Read master delete card
Read the 2nd user card
Note: The master delete card is used to delete card users continuously
and quickly.
When you read the master delete card for the first time, you will hear a short
“BEEP” sound twice and the indicator light turns orange, it means you have
entered into delete user programming, When you read the master delete card for
the second time, you will hear long “BEEP” sound once, the indicator light
turns red, it means you have exited the delete user programming.
Data Backup Operation
Example: Backup Iha data of machine A to machine B
The green wire and white wire of machine A connect with the green wire and
white wire of machine B correspondingly, set B for receiving mode at first,
then set A for sending mode, the indicator light turns green flash during the
data backup, data backup is successful when indicator light tums red.
#24, Shambavi Building, 23rd Main, Marenahalli, JP Nagar 2nd Phase,
Bengaluru – 560078
Phone : 91-8026090500 | Email