eSSL BG-CM-300 Boom Barrier User Manual

June 3, 2024
eSSL

USER MANUAL
Boom Barrier BG-CM-300

BG-CM-300 Boom Barrier

WARNING
AUTOMATIC BARRIERS ARE NOT FOR PEDESTRIAN!
To reduce the risk of INJURY or DEATH, read and follow all instructions.

  • NEVER let children operate or play with barrier control. Controller MUST be installed at least 1.5m above the ground.
  • PEDESTRIANS SHOULD NOT CROSS THE PATH OF THE MOVING BARRIER.
  • Automatic boom barrier is designed for vehicles ONLY. Pedestrians MUST use separate entrance.
  • Installation and maintenance MUST be executed by qualified service person. Keep boom barriers properly maintained.
  • Ground wire and current breaker MUST be connected.
  • Power MUST be cut off when performing installation or maintenance.
  • When power outage, power MUST be cut off before using the manual release under the motor to open the barrier.
  • ONLY operate when the boom barrier is in sight.
  • NEVER perform operating or setting without the boom installed. This WILL result in severe injury.
  • NEVER dismount the boom when barrier is at close status with spring attached. This WILL result in sever injury, even death.
  • DO NOT replace the original wire.

SAVE THESE INSTRUCTIONS.

Direction Definition and Main Components of the Machine

eSSL BG CM 300 Boom Barrier - Figure 1| eSSL BG
CM 300 Boom Barrier - Figure 2
---|---

Features

A. Remote control is allowed.
B. During power outage, product can be manual operated.
C. Control board contains various ports for parking lot management system, infrared sensor, radar, etc.
D. Product contains multiple limit protection functions to keep a long life time.

Specification

Rated Power 24VDC Brushless 240W
Power Supply 220V±10% 50/60Hz

110V±10% 50/60Hz
Working Temperature| -40 ℃~+60℃
Max. Boom Length| 2M
Operating Speed| 1~6s adjustable

Installation

4.1 Cabinet Installation

  • Open the Cabinet door and take out the attachment pack.
  • Place the 1 Cabinet at desired position.
  • Place 2 Fixed Bars on the bottom of the Cabinet inside.
  • Mark out the boreholes for 3 Expansion Bolts (Fig. 3: L and W) according to the Fixed Bars.
  • Move away the cabinet.
  • Use an electric drill with 21mm to drill the boreholes. The depth of the boreholes should be 110 ~ 120mm. Place the Expansion Bolts.
  • Move the cabinet back to the desired position and place the Fixed Bars on the bottom of the cabinet inside.
  • Tighten the Expansion Bolts.

eSSL BG CM 300 Boom Barrier - Figure 3 4.2 Boom Installation
4.2.1 Install the boom according to Fig2:eSSL BG CM 300 Boom Barrier -
Figure 4

Setting Springs’ Balance with Boom Weight

Attention: The springs are set to be balanced in factory. DO NOT change the boom length or weight if it is not necessary. If the boom length or weight must be changed (e.g.: adding a Stop Sign on the boom), the balance must be adjusted by a qualified service person.
5.1 Spring Quantity and Size

Boom Length Quantity of spring Spring Size
x≤2m 1 Φ3

Control Board Diagram

6.1 Electrical connectionsceSSL BG CM 300 Boom Barrier - Figure
5 6.2 Limits SettingeSSL BG CM 300 Boom Barrier -
Figure 6 Attention: Limits are set well in factory any change made on length, or maintain and change controller. Please follow steps below.
Before power on, manually adjust boom to middle position<45°> .
6.3 Function Parameter settingeSSL BG CM 300 Boom Barrier - Figure
7 6.3.1 Function Parameters

FO Reset (Caution)
Fl Open speed grade
F2 Open speed grade
F3 Auto-close timer (s)
F4 Count mode 0:Normal mode (default)
F5 05 default
F6 For back up
F7 Motor running direction 0:defavlt,1:reverse
F8 Open/close state Voltage Current Speed

Hull value Travel Save log
F9| Default 0 Hull limit
AO| Year
Al| Month
A2| Day
A3| Hour
A4| Minute
A5| Second
A6| Light-on Hour. Default: 18
A7| Light-on Minute. Default: 00
A8| Light-out Hour. Default: 06
A9| Light-out Minute. Default: 00

Transmitter ( Remote control ) setting

7.1 Transmitter’s code setting
Press “LEARN BUTTON’, the “LEARN LED’ light on, then, press and hold the button which you choose on the transmitter till the “LEARN LED” flashes and goes out, now, the transmitter is code. Other transmitter can be coded as this way.
7.2 Erasing the transmitter’s code
Press “LEARN BUTTON” and hold on to make the “LEARN LED” light on and till go out. Now, all codes of transmitters which had been learnt are cleared.
7.3Error Codes

Code Meaning Solution
E2 Motor Nonstop Running Over Limits 1.Check the Optical Counter Limits

Connecting 2.Check the Mechanical System
E3| Motor Locked Rotor| 1.Check the Mechanical System 2.Check Motor Wires Connectors
E5| Obnormal hull| Check the hull connection
E7| Photocell is Triggered| Remove the Object that Blocks the Photo Beam
E8| Air Wave Sensor Triggered| Remove the Object that Block the Air Wave

Maintain

  1. Frequently clean the surface of barrier and boom.
  2. Tighten the fasteners once a month.
  3. Inject lubricating oil every three month.
  4. Adjust balance each 30,000 times working.
  5. Check and replace wearing part parts every six month.
  6. Battery No. of remote is CR3216, replace the battery when battery runs out.

Packing list

No Name Quantity Mark
1 Barrier 1set
2 Boom 1pcs
4 Double end bolt 2pcs
5 Cap nut 4pcs M10
6 Flat washer 4pcs 10
7 Spring washer 4pcs 10
8 Gasket 2pcs
9 Anchoring 2pcs M14*140
10 Key 2pcs
11 Control unit 1pcs Including 2pcs remotes
12 Manual 1pcs