TCD UC65E H-1X and UC65e Drain Water Tempering Valve Kit Instructions
- June 13, 2024
- TCD
Table of Contents
H-1X & UC65e Drain Water
Tempering Valve Kit
PN 13470.55
INSTALLATION INSTRUCTIONS TO DRAIN TEMPERING KIT
NOTE: Turn the dishwasher’s wall breaker to “OFF” position before this installation.
- Undo the drain hose clamp connecting drain hose leading to floor drain
- Install the water junction tee, as shown on drain line, and tighten clamp
- Connect the drain hose to upper port of water injection tee and tighten hose clamp
- Insert the provided white chemical tube into compression nut of water injection tee and tighten compression nut
- Connect the provided cold-water solenoid’s power leads to the drain solenoid
- Connect the water injection assembly’s ball valve to a cold water supply.
- Run the dishwasher through a few cycles and make sure the cold water is injected and check for any possible leaks.
ITEM NO. | NO. REQ’D | P/N | DESCRIPTION |
---|---|---|---|
1 | 3. | 15400. | 3/8″ Slit ribbed Tubing |
2 | 1 | 15603.50 | Goose Neck Pipe Adapter Tee |
3 | 2 | 00425.54 | Chemical Tubing White |
4 | 2 | 03415.50 | Flex-tight Fitting |
5 | 1 | 41014. | 3/8″ Ball Valve |
6 | 2 | 40015.00 | 3/8″ X 1/4″ Hex Bushing |
7 | 1 | 41015.00 | Solenoid Valve 1/4″ 115V |
8 | 1 | 40112.00 | 1/4″ Comp X 1/4″ MIP Elbow |
9 | 2 | 03101.00 | Hose Clamp #16 1″ |
10 | 0.25 | 03108.60 | Transfer Hose 1″ Reinforced |
Read User Manual Online (PDF format)