V-TAC VT-118S Pir Sensor Floodlight with Direct Connection Instruction Manual

June 4, 2024
V TAC

118S Pir Sensor Floodlight with Direct Connection
Instruction Manual PIR SENSOR FLOODLIGHT WITH DIRECT CONNECTION

TECHNICAL DATA

MODEL VT-118S VT-128S VT-138S VT-158S
LUMENS 735lm 1510lm 2340lm 4000lm
WATTS 10w 20w 30w 50w
BEAM ANGLE 100° 100° 100° 100°
CRI >80 >80 >80 >80
DF >0.9 >0.9 >0.9 >0.9
DIMENSION 113x133x60mm 128x157x60mm 143x177x60m 178x195x60mm
INPUT POWER AC: 220-240V, 50Hz
INSTALLATION HEIGHT 1.8m~2.5m
TIME DELAY Mi n: 10s ec+3s ec; Max: 7mi n+2mi n
DETECTION RANGE 140°+20°
DETECTION DISTANCE

INTRODUCTION & WARRANTY

Thank you for selecting and buying the V-TAC product. V-TAC will serve you the best. Please read these instructions carefully before starting the installation and keep this manual handy for future reference. If you have any other queries, please contact our dealer or local vendor from whom you have purchased the product. They are trained and ready to serve you at their best. The warranty is valid for 5 years from the date of purchase. The warranty does not apply to damage caused by incorrect installation or abnormal wear and tear. The company gives no warranty against damage to any surface due to incorrect removal and installation of the product. The products are suitable for 10-12 Hours of Daily operation. Usage of the product for 24 Hours a day would void the warranty. This product is warranted for manufacturing defects only.

WARNING

  • Please make sure to turn off the power before starting the installation.
  • Installation must be performed by a qualified electrician.
  • The light source of this luminaire is not replaceable, when the light source reaches its end of life the whole luminaire should be replaced.
  • Proper grounding should be ensured throughout the installation.
  • Replace any cracked protective shield.
  • The minimum distance from lighted objects is 1m.

This marking indicates that this product should not be disposed of with other household wastes.

Caution, risk of electric shock.

MULTI-LANGUAGE MANUAL QR CODE
Please scan the QR  code to access the manual in multiple languages.

http://vtac.store/vt118s
INSTALLATION DIAGRAMV-TAC VT-118S Pir Sensor Floodlight with Direct
Connection - fig

INSTALLATION INSTRUCTION

  1. Switch off the power. Confirm the installation position.
  2. Punch holes in the building surface with an impact drill.
  3. Insert expansion bolt.
  4. Fixed bracket.
  5. Turn on the connector counterclockwise, and pass the sorted cable through the waterproof cap and connector in turn.
  6. The cable is connected to the terminal, the live wire is connected and installed L, and the zero wire is connected to N, the Ground wire is connected to, tighten the screw of the terminal block.
  7. Turn the connector and waterproof cap clockwise, and pay attention to the fact that the waterproof joint nut must be tightened, otherwise, there is a hidden danger of water leakage. The rubber-covered part of the outer lead should extend into the waterproof cap for more than 15mm, otherwise, there is a hidden danger of water leakage.
  8. Switch on the power and test the light.

FUNCTION

  • LUX Setting: Can identify day and night. The consumer can adjust the work ambient light. It can work during the daytime and at night when adjusted to the “sun” position  (max). It can work in ambient light less than 10LUX when it is adjusted on the “moon” position (min). As for the adjustment pattern, please refer to the testing pattern.
  • SENS adjustable: For low sensitivity with 3m for detection distance set the SENS knob to (-); for High sensitivity with 10m set the knob to (+).
  • Time-Delay is added continually: When it receives the second induction signal after the first induction, it will compute time once more on the basis of the first time-delay rest. Time–Delay is adjustable. It can be set according to the consumer’s desire. The minimum time is 10s. The maximum is 7 min.

TEST

  • Turn the SENS knob clockwise on the maximum (+). Turn the TIME knob anti-clockwise on the minimum(-). Turn the LUX knob clockwise on the maximum(sun).
  • When you switch on the power, the light will be on at once, and 5-30 seconds later will be off automatically. Then if the light receives an induction signal, it can work normally
  • After 10sec of the first detection, the light could work again. If there is no induction signal, the load will stop working within 10sec.
  • Turn the LUX knob anti-clockwise to a minimum. If it is adjusted to 10LUX the load and the sensor should not work when testing in daylight. If you cover the detection window with opaque objects such as towels etc, the load will work. Under no induction signal, the load will stop working within 10 seconds.

Note: When testing in daylight, please turn the LUX knob to the (SUN) position, otherwise the sensor lamp will not work.

  • In front of the detection window please ensure there are no hindering or unrest objects effecting the detection.
  • The working temperature will affect the detection distance. The working temperature is -20°C ~+ 24°C

**TROUBLESHOOTING

**

  1. Why does the sensor not switch OFF the light automatically?
  • Please check if there is a continuous signal in the detection field.
  • Please check if the time delay has been set to maximum.
  • Please check if the power corresponds to the instructions.
  • Please check if the temperature near the sensor changes such as air conditioning or central heating.

2. Why is the sensitivity of the sensor poor?

  • Please check if there is any hinder in front of the detection window.
  • Please check if the ambient temperature is too high.
  • Please check if the induction signal source is in the detection field.
  • Please check if the installation height corresponds to the installation height mentioned in the instructions.

IN CASE OF ANY QUERY/ISSUE WITH THE PRODUCT, PLEASE REACH OUT TO US AT: SUPPORT@V-TAC.EU FOR MORE PRODUCTS RANGE, INQUIRY PLEASE CONTACT OUR DISTRIBUTOR OR NEAREST DEALERS. V-TAC EUROPE LTD. BULGARIA, PLOVDIV 4000, BUL.L.KARAVELOW 9B

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals