SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

  • To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
  • Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
  • Installation and service of luminaires should be performed by a qualified licensed electrician.
  • Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
  • It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
  • DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
  • Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
  • These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.

WARNING
RISK OF ELECTRIC SHOCK

  • Disconnect or turn off power before installation or servicing.
  • Verify that supply voltage is correct by comparing it with the luminaire label information.
  • Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
  • All wiring connections should be capped with UL approved recognized wire connectors.

WARNING RISK OF BURN

  • Allow lamp/fixture to cool before handling. Do not touch enclosure or light source.
  • Do not exceed maximum wattage marked on luminaire label.
  • Follow all manufacturer’s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.

CAUTION RISK OF INJURY

  • Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
  • Avoid direct eye exposure to the light source while it is on.

CAUTION  RISK OF FIRE

  • Keep combustible and other materials that can burn, away from lamp/lens.
  • Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.

CAUTION: RISK OF PRODUCT DAMAGE

  • Never connect components under load.
  • Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
  • Unless individual product specifications deem otherwise: Never connect an LED product directly to a dimmer packs, occupancy sensors, timing devices, or other related control devices. LED fixtures must be powered directly off a switched circuit.
  • Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
  • Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient temperature.
  • Only use fixture in its intended location.
  • LED products are Polarity Sensitive. Ensure proper Polarity before installation.
  • Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.
  • Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
  • some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.
  • Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings.

Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory statements.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com.

Indoor/Outdoor
Lithonia Lighting
Carandini
Holophane
RELOC

Indoor Lighting Outdoor Lighting Controls

Gotham American Electric Lighting  DARK TO LIGHT
Mark Architectural Lighting Antique Street Lamps Lighting Control & Design
Peerless Hydrel  ROAM
Renaissance Lighting Tersen  Sensor Switch
Winona Lighting Tersen  Synergy

Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products. ABL LED General Warnings, Form No. 503.203
© 2011 Acuity Brands Lighting, Inc. All rights reserved. 04/18/11

AFTER INSTALLATION DELIVER THIS MANUAL TO OWNER

AcuityBrands-ESL2
-Esplanade-Tear-Drop-Large-Roadway-LED-Pendant-figv 1

IMPORTANT SAFETY INSTRUCTIONS

WARNING – READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL OR MAINTAIN THIS FIXTURE. WORK MUST BE DONE BY QUALIFIED PERSONNEL.
WARNING – BE CERTAIN THAT ALL ELECTRICAL POWER IS DISCONNECTED FROM THE FIXTURE BEFORE INSTALLING OR MAINTAINING THE FIXTURE.
WARNING – FOLLOW LAMP MANUFACTURER’S OPERATING AND MAINTENANCE INSTRUCTIONS.
FAILURE TO FOLLOW THESE WARNINGS
MAY RESULT IN DEATH, INJURY OR SIGNIFICANT PROPERTY DAMAGE.

INTRODUCTION

Product Description

  • This fixture is designed to operate an LED light source at up to 245 watts.
  • This fixture must be serviced by trained electrical personnel.
  • This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Alternate Information Sources.

INSTALLATION

Tools and Materials Required

DESCRIPTION USE
Flat blade screwdriver Terminal block connections

Pendant Mount:

  • 3/16” Allen wrench Setscrew
  • Pipe Thread Sealant Mounting pipe threads

Stem Mount:

  • 1/8″ Allen wrench Setscrew
  • 3/16” Allen wrench Setscrew
  • 1/4” Allen wrench Setscrew
  • 9/16” Socket Nuts
  • 3/8” Socket Screws

Fixture Installation

  • Remove the mounting assembly from the electrical housing by releasing the latch and then swinging it open until the hinge disengages. See Figure 1.
  • Loosen the wire chamber cover screws and remove the wiring chamber cover. Allow it to hang by the electrical wires attached to the terminal block. See Figure 1.
    Figure 1AcuityBrands-ESL2-Esplanade-Tear-Drop-Large-Roadway-LED-Pendant-
figv 2

Pendant mount
This unit must be mounted to a 1-1/2 NPT male threaded pendant. Verify that the set screw, located in the mounting assembly, is backed out enough that it will not interfere with the mounting threads. See Figure 1. Thoroughly inspect threads for damage. DO NOT attempt to assemble with another part if any thread damage is found on either part. Apply pipe thread sealant completely around the first 4 male threads on the mounting pendant. Force the sealant into the threads, see Figure 2. Thread the mounting assembly onto the pipe threads. Tighten by hand at least 5 full turns to ensure the end of the conduit goes past the setscrew hole
Figure 2

CAUTION
FIELD APPLICATION OF PIPE THREAD SEALANT IS REQUIRED. FAILURE TO PROPERLY APPLY PIPE THREAD SEALANT COULD CAUSE THIS UNIT TO LEAK OR CAUSE INADEQUATE THREAD ENGAGEMENT.
PIPE THREAD SEALANT MUST BE APPLIED TO MALE THREAD ASSEMBLY TO ENSURE PROPER INSTALLATION

Rigid Pendant mounting – Thread the mounting assembly onto the pipe threads. Tighten by hand at least 5 full turns to insure the end of the conduit goes past the setscrew hole. Continue to tighten with wrench until the threads tighten completely and the street side of luminaire is pointed in proper direction. Reflector assembly and refractor are marked “street side.”
Tighten the set screw to 12-15 ft-lbs.

Quick Stem Mount
Refer to Installation Manual provided with the swivel fitter (IM-347) Attach the luminaire to the fitter by removing fitter door and inserting stem of luminaire into the fitter. (Fig 3) Do not damage the electrical supply wires during attachment of the luminaire. Feed the electrical supply wires through the center of the stem grommet and make final connection per section 2.2.7. Replace the fitter door by engaging the lip of the door inside the fitter. Tighten the door screws to 5-6 Ft-lbs. Tighten the nuts on the U-bolts to 30-40 Ft-lbs. Allow luminaire to self-level and tighten the set screws to 12-15 Ft-lbs. If necessary, adjust the leveling set screws so that the fitter is installed level. Install shaft collar on stem in upmost position, flush with fitter.
Figure 3

Remove wire chamber cover and connect the electrical supply wires to the terminal block in the back of the electrical chamber. The terminals are marked “L1” (Line 1). “G” (Ground), and “L2” (Line 2). If one of the supply lines is electrically neutral, it should be connected to terminal “L2”. (Fig 1) Replace wire chamber cover.
DM Option For units equipped with 0-10V dimming, locate the gray and purple leads from the driver module. These are to be used with a Holophane approved control circuit.

CAUTION
LEADS USED FOR DIMMING CONTROLS ARE TO BE SEPARATED FROM MAIN POWER CONDUCTORS IN A MANNER TO SATISFY STATE AND LOCAL CODES.
Hang the electrical assembly on the mounting assembly hinge and plug in the electrical connector. See Figure 4.
If equipped with a photocontrol receptacle, insert photocell and position eye towards lens. Swing the electrical assembly closed and engage the latch to the catch to securely close unit.
Hang the refractor assembly on the door hinge. Swing the refractor assembly closed, engage the closure bolt and tighten the wing nut securely. See Figure 5.
If using Flat Glass (FG) Option, REMOVE BLUE FILM FROM GLASS.

OPTICS ORIENTATION NOTE
The product has a molded-in “STREET SIDE” marking. Insure that this side is aimed toward the street.
Electrically energize the fixture and check for proper operation.
Figure 4AcuityBrands-ESL2-Esplanade-Tear-Drop-Large-Roadway-LED-Pendant-
figv 5

Figure 5

MAINTENANCE

Relamping and Cleaning

Wipe off exterior dirt and debris.
Loosen the wing nut securing the refractor assembly and disengage the closure bolt, swinging the refractor open slowly. See Figure 5.
Inspect the LED board and reflector assembly. These are maintenance free items and should never be touched, adjusted or wiped with any cleaner.
Wipe off the refractor and reflector with a dry cloth. If the refractor needs to be washed, use water and detergent.

CAUTION
DO NOT USE ABRASIVE CLEANSERS ON OPTICAL SURFACES. THEIR USE MAY RESULT IN THE LOSS OF OPTICAL PERFORMANCE.
Swing the refractor assembly closed, engage the closure bolt and tighten the wing nut securely. See Figure 5.

Electrical Component Replacement.

NOTE
The entire fixture below the mounting assembly (Fig 1.) may be removed in the field to allow further maintenance of the module to be performed in the shop.
The fixture contains a surge protection module (Shown in Fig 4) that is meant to fail in case of electrical spikes or over voltage conditions. Remove this and replace to see if this restores power to the circuit.
Disengage the latch securing the fixture to the mounting assembly and swing the fixture open slowly.
Disconnect the electrical connector and then remove the fixture from the mounting assembly by swinging the fixture open on the hinge far enough to disengage the hinge pin from the hinge hook. See Figure 1.
Remove the electrical module by loosening the two attachment screws and disengaging the module from the screw heads and lift the module from the electrical housing. See Figure 1.
Carefully note the position and attachment means for all components and wiring and tag all wiring that will be disconnected. Remove the screws, straps and brackets securing the component(s) and save all mounting hardware for reuse.
Replace with Holophane supplied electrical components, positioning the new component exactly as was the old. Secure with the original hardware and tighten all fasteners securely.
Rewire based on the tags applied earlier and according to industry accepted wiring techniques. Reposition all wiring and secure it as it was originally.
Carefully reinstall the electrical module into the electrical housing; tighten all screws securely. See Figure 4.
ang the fixture on the hinge hook of the mounting assembly and plug in the electrical connector. Swing the electrical assembly closed and engage the latch to the catch to securely close unit. See Figure 1.
Electrically energize the fixture and check for proper operation.

Limited Warranty and Limitation of Liability

The Holophane limited warranty and limitation of liability is published in the “Terms and Conditions” section of the current Holophane buyer’s guide, and is available from your local Holophane sales representative.
Failure to properly install this Unit will void all warranties.

LIMITED WARRANTY AND

LIMITATION OF LIABILITY
Complete warranty terms located at: www.acuitybrands.com/support/warranty /terms-and-conditions

ADJUSTABLE OUTPUT (AO) TABLES

Field Adjustable Output Module
The Field Adjustable Output (AO) module is an onboard device that adjusts the light output and input wattage to meet site specific requirements, allowing a single fixture configuration to be flexibly applied in many different applications.

P10S: MVOLT and HVOLT

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 94%| 94%
6| 80%| 80%
5| 68%| 68%
4| 55%| 55%
3| 41%| 42%
2| 28%| 29%
1| 37%| 41%
P15S: MVOLT and HVOLT

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 94%| 94%
6| 80%| 80%
5| 68%| 68%
4| 55%| 55%
3| 42%| 42%
2| 28%| 29%
1| 14%| 15%
P20S: MVOLT and HVOLT

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 94%| 94%
6| 81%| 80%
5| 69%| 68%
4| 56%| 54%
3| 42%| 41%
2| 29%| 29%
1| 14%| 15%
P20U: MVOLT and HVOLT

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 94%| 94%
6| 81%| 80%
5| 69%| 68%
4| 56%| 55%
3| 43%| 42%
2| 29%| 29%
1| 15%| 15%
P25S: MVOLT and HVOLT

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 94%| 94%
6| 81%| 80%
5| 69%| 67%
4| 56%| 54%
3| 43%| 41%
2| 29%| 28%
1| 15%| 15%
P25U: MVOLT and HVOLT

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 94%| 94%
6| 81%| 80%
5| 69%| 68%
4| 56%| 54%
3| 43%| 41%
2| 30%| 29%
1| 15%| 15%
P30S: MVOLT and HVOLT

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 94%| 94%
6| 81%| 80%
5| 69%| 67%
4| 56%| 54%
3| 43%| 41%
2| 30%| 28%
1| 15%| 15%
P30U: MVOLT and HVOLT

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 94%| 94%
6| 81%| 80%
5| 70%| 67%
4| 57%| 54%
3| 44%| 41%
2| 30%| 29%
1| 15%| 15%
P35S: MVOLT and HVOLT

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 94%| 94%
6| 81%| 79%
5| 70%| 67%
4| 57%| 54%
3| 44%| 41%
2| 30%| 28%
1| 15%| 15%
P40S: MVOLT and HVOLT

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 95%| 94%
6| 82%| 79%
5| 70%| 67%
4| 57%| 54%
3| 44%| 41%
2| 31%| 28%
1| 16%| 15%
P45S: MVOLT and HVOLT

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 95%| 94%
6| 82%| 79%
5| 71%| 67%
4| 58%| 54%
3| 45%| 41%
2| 31%| 28%
1| 16%| 14%
P50S: MVOLT and HVOLT

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 95%| 94%
6| 82%| 79%
5| 71%| 67%
4| 59%| 54%
3| 45%| 41%
2| 32%| 28%
1| 16%| 14%
P55S: MVOLT and HVOLT

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 95%| 94%
6| 83%| 79%
5| 72%| 67%
4| 59%| 54%
3| 46%| 41%
2| 32%| 28%
1| 17%| 14%
P60S: MVOLT and HVOLT

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 95%| 94%
6| 83%| 79%
5| 72%| 67%
4| 60%| 54%
3| 47%| 41%
2| 33%| 28%
1| 17%| 14%
P65S: MVOLT and HVOLT

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 95%| 94%
6| 84%| 79%
5| 73%| 67%
4| 61%| 53%
3| 48%| 40%
2| 33%| 28%
1| 18%| 14%

Acuity Lighting Group, Inc.
3825 Columbus Rd. S.W. Granville, OH 43023
IM-396 12/1 ©2021 Acuity Lighting Group Inc.

ALL RIGHTS RESERVED.
Visit our web site at www.holophane.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

AcuityBrands User Manuals

Related Manuals