RAB T10 EM LED Tube Light Instructions

June 9, 2024
RAB

RAB T10 EM LED Tube Light Instructions

IMPORTANT

READ CAREFULLY BEFORE INSTALLING LAMPS. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. lamps required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
TYPE B LAMP – Intended for operation in luminaires with traditional fluorescent-type lampholders wired directly to the branch circuit. This includes both factory-wired luminaires as well as those converted for this purpose under a retrofit program.
WARNINGS: • Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.

  • Risk of fire or electric Install this kit only in luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire.
  • To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp
  • To avoid potential fire or shock hazard, do not use this retrofit kit in luminaires employing shunted bi-pin lampholders. Note: Shunted lamp holders are found only in fluorescent luminaires with Instant-Start ballasts. Instant-start ballasts can be identified by the words “Instant Start” or “I.S.” marked on the This designation may be in the form of a statement pertaining to the ballast itself, or may be combined with the marking for the lamps with which the ballast is intended to be used, for example F40T12/IS. For more information, contact the LED luminaire retrofit kit manufacturer.”
  • Installers should not disconnect existing wires from lampholder terminals to make new connections at lampholder Instead installers should cut existing lampholder leads away from the lampholder and make new electrical connections to lampholder lead wires by employing applicable connectors.

THE RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION. PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH THE APPLICABLE AND APPROPRIATE ELECTRICAL CODES. THE INSTALLATION GUIDE DOES NOT SUPERSEDE LOCAL OR NATIONAL REGULATIONS FOR ELECTRICAL INSTALLATIONS

CAUTION:

Installers should examine all parts that are not intended to be replaced by the retrofit kit for damage and replace any damaged parts prior to installation of the retrofit kit.

  • Disconnect power at the source before installation, inspection or Do not simply switch off fixture.
  • This item is rated at 120-277V. Installer must determine whether line voltage 120-277V is available at the luminaire before
  • Not intended for use with exit fixtures or exit
  • Over 90 minutes back up working time with typical 400 lumen output
  • The battery in this device is not user Refer service to manufacturer’s qualified personnel only. Do not incinerate”
  • Do not immerse the battery into the water or the sea, Guard against Damp
  • Do not approach the heat source, like fire or heater;
  • Do not discard the battery to the fire or hyperpyretic objects
  • Please use the battery in normal as follows, or it will be overheating, caught fire , reduced performance and shorten the life;

Environment condition (Temperature) charging: 0~+40°C (+32~+104°F) Discharging: -20~+60°C (-4~+140°F) Storage within: -20~+35°C (-4~+95°F)

  • Risk of fire or electric Do not open or modify. No user serviceable parts inside.
  • Installers should not disconnect existing wires from lamp holder terminals to make new connections at lamp holder Instead installers should cut existing lamp holder leads away from the lamp holder and make new electrical connections to lamp holder lead wires by employing applicable connectors.
  • SUITABLE FOR DAMP Not for use where directly exposed to the weather or water.
  • SUITABLE FOR “TYPE IC” OR “TYPE NON-IC”
  • No external weight or mechanical force should be applied to tube or
  • The operating instructions shall provide appropriate information regarding temperature limits during battery charging, use and storage, as well as for the safe disposal of the
  • Do not make or alter any open holes in an enclosure of wiring or electrical components during kit
  • LAMP COMPARTMENT DIMENSIONS “121 cm(L) x 61 cm(W) x 5 cm(H)” [47.64inch(L) x 24inch(W) x 1.97inch(H)]

LED TUBE INSTALLATION GUIDE

  • Disconnect power to the
  • Remove existing fluorescent
  • Remove ballast
  • Cut all the wires to Note: Ballast must remain in place.
  • Remove existing lamp holders.
  • Replace existing lamp holders with new non-shunted lamp holders to install with the T10EM LED tube in the fixture. Refer to wiring diagram in 1. (EM Test switch and non-shunted lamp holders sold separately).
  • Reinstall the ballast
  • IMPORTANT: Turn on the battery connection switch near the red endcap (Fig. 3).

The battery connection switch comes with a default “off” to prevent the built- in battery from being depleted and/or damaged. The lamp may be lit at a dim light level powered by the built-in battery.

  • Install the lamp in the lamp holders (Fig. 2), the lamp will have to be rotated to be locked into place and receive
  • Adhere the enclosed notice label to the reflector of the
  • Restore power to the fixture and turn the light on with the wall
  • The lamp should be lit at full
  • Regulatory compliance tests: Refer to EM Testing
  • Indicator working status (see 4).

LED TUBE INSTALLATION GUIDE

  • Disconnect power to the

  • Remove existing fluorescent

  • Remove ballast

  • Cut all the wires to Note: Ballast must remain in place.

  • Remove existing lamp holders.

  • Replace existing lamp holders with new non-shunted lamp holders to install with the T10EM LED tube in the fixture. Refer to wiring diagram in 1. (EM Test switch and non-shunted lamp holders sold separately).

  • Reinstall the ballast

  • IMPORTANT: Turn on the battery connection switch near the red endcap (Fig. 3).
    The battery connection switch comes with a default “off” to prevent the built- in battery from being depleted and/or damaged. The lamp may be lit at a dim light level powered by the built-in battery.

  • Install the lamp in the lamp holders (Fig. 2), the lamp will have to be rotated to be locked into place and receive

  • Adhere the enclosed notice label to the reflector of the

  • Restore power to the fixture and turn the light on with the wall

  • The lamp should be lit at full

  • Regulatory compliance tests: Refer to EM Testing

  • Indicator working status (see 4).

Model Number

| Input Ratings| Lamp|

LED Lamps Tested in Luminaire

| Minimum Luminaire Dimension

with Max. No. of Tubes

| Lamp Holder to Lamp Holder Spacing
---|---|---|---|---|---
V| Hz| A| W| Length| Length x Width x Height

T10EM-17-48P-8xx-SE-BYP

|

120-277

|

50-60

| 0.16| 17 (with battery fully charged)|

48 inch

|

4

| 121 x 61 x 5 cm

47.64 x 24 x 1.97 inch

| 11 cm

4.33 inch

0.18| 21 (with battery in charging)

EM TEST SWITCH INSTALLATION INSTRUCTIONS:

Note:

  1. Switch on The Power to Breaker
    If no existing Emergency Test Switch in the fixture system, you can follow these instructions after purchasing the relevant accessory kit from RAB Lighting.
    If there is an existing Emergency Test Switch in the fixture system, you can replace the existing tubes and ensure the Test Switch can still work properly according to the EM TESTING GUIDE.

EM TESTING GUIDE

  1. Press the test button to cut the power to the AC driver and switch the system to emergency mode. Release the test button to return to normal mode

ROUTINE TESTING SCHEDULE

  1. Ensure he wall swi ch 0ff.
  2. Depress he es bu on and hold
  3. Conduc a 30–second discharge es by depressing he es bu
  4. The LED load should opera e a reduced lumen ou pu .
  5. Allow a 24–hours charge before conduc ing es .
  6. Ensure he wall swi ch 0ff.
  7. Keep he es bu on depressing or swi ch off he circui Breaker
  8. Conduc a full 90–minu e discharge es .
  9. The uni should opera e as in ended forhe dura ion of he es .

ACCESSORY PACKAGE

Accessory includes:

  • Two lampholders– one wi h whi e ro or, one wi h red ro
  • Two P3 wiring orange
  • 0ne Emergency Tes Swi

Note: The se of accessory ki needs o be ordered separa ely.

EM TEST SWITCH DRAWING

NFPA 101, Life Safety Code outlines the following schedule:
“Written records of the testing shall be kept by the owner for inspection by the authority having jurisdiction.”

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals