Introduction
Please read these instructions in their entirety before commencing with the installation. Save these instructions and pass them on to third parties, as appropriate.
Scope of Delivery
Please check immediately after unpacking the goods whether the shipment is complete and the merchandise is in good condition.
- automatic cable reel
- wall anchors
Specifications
General
- Operating voltage 230 V / 50 Hz
- Child protection yes
- Overheating protection yes
- Pivotable 180º
Model KT A92 V315 DE
- Total cable length 9 + 2 metres
- Cable type H05VV-F3G1,5
- Max. load:
- Coiled 1,400 Watt
- Uncoiled 2,000 Watt
- Protection type IP20
- The automatic cable reel is suitable for use in dry interior rooms.
Model KT A92 N315 IP44 DE / BE
- Total cable length 9 + 2 metres
Model KT A162 N315 IP44 DE
- Total cable length 16 + 2 metres
Model KT A92 N315 IP44 DE / BE Model KT A162 N315 IP44 DE
- Cable type H07RN-F3G1,5
- Max. load:
- Coiled 1,000 Watt
- Uncoiled 3,500 Watt
- Protection type IP44
- The automatic cable reel is suitable for permanent outdoor use.
Mounting
- The automatic cable reel features a holder with two mounting holes.
- Using the holder’s mounting holes as guides, mark the location of the bore-holes for mounting.
- Drill the required holes.
- Use suitable mounting material (M 6 screws) to attach the automatic cable reel.
Operation
- Connect the plug of the automatic cable reel to a mains socket.
- Connect an appliance to the automatic cable reel’s safety socket.
- The automatic cable reel features a cable management system with automatic rewind capability.
- The cable snaps in place after each half turn, and automatic rewinding stops.
- To coil up the cable, pull the cable until it releases from the locked position (makes no sound), then slowly let the cable rewind.
- IMPORTANT: The tractive forces are very high. Avoid uncontrolled rewinding of the cable. Hold the cable end and slowly guide it towards the automatic cable reel.
Overheating Protection
- The LED on the automatic cable reel lights up red to show that the overheating protection is working.
- The LED goes out when the overheating protection is triggered (56+/-5 ºC).
- In that case the power plug must be disconnected.
- After a short cooling-off period, you can start using the automatic cable reel again by pressing the red button.
Safety Notes
- All installation and repair work must be carried out by a qualified technician.
- Make sure when changing lines that the shortest possible path is used to connect the L/N conductors to the clamps and that the earth wire is connected to the marked clamp and is at least 12 mm longer than the other L/N conductors.
- If necessary, the overheating protection must be replaced with a new component with the same rated values.
- The plugs must be disconnected from the outlet before the cable is coiled or uncoiled.
- Do not exceed the maximum load (see Specifications).
Maintenance / Cleaning
Important: Make sure the automatic cable reel is de-energised for
cleaning. To de-energise the cable reel, disconnect the safety plug from
the mains socket.
This product does not require servicing. To clean the exterior of the
automatic cable reel simply wipe with a clean, dry cloth. Make sure the
automatic cable reel does not get wet.
Dispose of electrical devices in an environmentally responsible manner! Do not dispose of electrical devices with household rubbish
In accordance with Directive 2012/19/EC on waste electrical and electronic equipment, used electrical equipment must be collected separately and reused or recycled in an environmentally responsible manner. Please contact your local authorities for available disposal options for your worn-out device.
Addresses
Hugo Brennenstuhl GmbH & Co. KG Seestraße 1-3 · D-7207 4 Tübinge n H. Brennenstuhl S.A.S. · lectra-t ag · Blegistrasse 13 · CH-6340 Baar www.brennenstuhl.com Instructions for use Automatic Cable Reel 3 042213 Automatik-Kabeltrommeln 30.04.13 14:12 Seite 3 4 rue de Bruxelles · F-67170 Bernolsheim
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>