Qlima GFA 1010 Gas Heater Instruction Manual

June 9, 2024
Qlima

Qlima-GFA-1010-Gas-Heater-LOGO

Qlima GFA 1010 Gas Heater

Specification

  • Model name
  • Capacity
  • Gas < 15 kg
  • Gas category
  • PIN
  • Consumption (max.)
  • Made in
  • GFA 1010
  • 10 kW
  • LPG I3B/P – I3P 700 mbar
  • I3B/P G30* // I3P G31**
  • 1008CR2976
  • 730 gr/hr
  • P.R.C
  • Countries of Destination
  • IPX4
    • 220-240V~
  • 50Hz
    • 25W
  • < 0.5 A

– FOR OUTDOOR USE ONLY – Close the valve of the gas cylinder or the regulator after use – The use of this appliance in enclosed areas can be dangerous and is PROHIBITED. – Read the instructions before using this appliance – The appliance must be installed in accordance with the instructions and local regulations. – For use outdoors and in well ventilated areas. – A well ventilated area must have a minimum of 25% of the surface area open. – The surface area is sum of the walls surface. – Air delivery temperature classification: space heating appliance. – Use away from combustible materials.
NOT TO BE USED FOR THE HEATING OF HABITABLE AREAS OF DOMESTIC PREMISES; FOR USE IN PUBLIC BUILDINGS REFER TO NATIONAL REGULATIONS.
Check the heater for possible shipping damage. Connect the hose and regulator assembly to the LPG cylinder. Open the cylinder’s gas valve and check all gas connections with a soap and water solution. Connect power cord to well- grounded 220V~, 50Hz source of power. – Turn the power switch to position I and check that the fan starts running correctly. – Push the gas valve button and push repeatedly (!!) the ignitor (piezoelectric lighter) until the flame lights up. – As the flame lights up, keep the valve button pushed for 10 seconds approx. Should the heater stop when the valve button has been released, wait one minute and repeat the starting operation keeping the valve button pushed for a longer time. – Contact your supplier should any problem continue.
SWITCH OFF: To stop the heater, shut off the gas cylinder tap. Let the fan run until the flame shuts down and then turn the fan switch to position O. Gas connection 1/4”LH. To be used with 700 mbar regulator. Ensure that the fan is operating correctly before lighting the burners.

DIRECTIONS FOR USE

  • This heater is for outdoor use only. Indoor use is dangerous.
  • An amply ventilated area must have a minimum of 25% of the surface area open. The surface area is the sum of the walls surface
  • Read this user manual carefully before using the appliance and keep it for futu-re reference. Install this device only when it complies with local/national legislation, ordinances and standards.
  • This product is intended to be used as space heater for heating the working envi-ronment of people in non-domestic envi-ronments.
  • NOT TO BE USED FOR THE HEATING OF HABITABLE AREAS OF DOMESTIC PREMISES; FOR USE IN PUBLIC BUILDINGS REFER TO NATIONAL REGULATIONS.
  • After unpacking, check the appliance for any damages. When in doubt, do not use the appliance, but contact customer ser-vice at your local dealer’s. Keep the pac-kaging materials (plastic bags, etc.) away from children, as they may cause hazar-dous situations to children.
  • No modifications to the safety system are allowed.
  • This heater is constructed in conformity with relevant texts in the EN1596:1998/A1:2004 standard
  • Keep the instructions for future reference

WARNINGS

  • Read the instructions before installation and use. This appliance must be installed and the gas cylinder stored in accordance with the regulations In force.
  • Only use the device for its intended pur-pose. Other usage may lead to burns, fire, explosion, crash, asphyxiation, car-bon monoxide poisoning and/or electrical shock, etc.
  • Install the heater only if it complies with local regulations, laws and standards;
  • Check if the information indicated on the type plate corresponds your situation befo-re you connect the appliance.
  • I nstall the heater according to the instruc-tions as described in the installation sec-tion of the directions for use;
  • This heater is manufactured according to CE safety standards. Nevertheless, as with any other heating device, care must be taken;
  • RISK OF FIRE Never use the heater in pla-ces where inflammable and/or harmful Gases, products or fumes may be present (e.g. exhaust gases, paint fumes, curtains, paper, clothes);
  • If the heater is positioned too close to inflammable materials you may risk fire;
  • For safety reasons take care when children or animals are in the proximity of the hea-ter, as with any other heating device, and make sure that children are always aware of the presence of a hot heater;
  • This appliance is not intended for use by persons (including children) with redu-ced physical, sensory or mental capabili-ties, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the applian-ce by a person responsible for their safety.
  • I f the heater is damaged, it shall be repaired by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • Children should be supervised to ensure that they do not play with the appliance.
  • In order to avoid overheating, do not cover the device.
  • The guard of this heater is intended to pre-vent direct access to heating elements and must be in place when the heater is in use.
  • Do not insert objects into the openings of the device.
  • The guard does not give full protection for young children and infirm persons.
  • This appliance can be used by children aged from 12 years and above and persons with reduced physical, sensory or men-tal capabilities or lack of experience and knowledge if they have been given super-vision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Cleaning and user maintenance shall not be made by children without supervision.
  • Children of less than 3 years should be kept away unless continuously supervised.
  • Children aged from 3 years and less than 8 years shall only switch on/off the appli-ance provided that it has been placed or installed in its intended normal operating position and they have been given super-vision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenan-ce.
  • CAUTION – some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are pre-sent.
  • During operation and just after operation the appliance will be extremely hot. NEVER touch it during operation or just operati-on. NEVER move the appliance during this time.
  • Switch off the appliance when it is unat-tended.
  • Do not cover or obstruct the heater when in use.
  • If you fail to consult and/or follow up the rules, instructions and explanation, the warranty will no longer be valid, and the manufacturer will no longer deal with any damage to the appliance and/or your envi-ronment under the warranty.
  • Read the instructions before installation and use.
  • This appliance must be installed and the gas cylinder stored in accordance with the regulations in force.
  • Do not obstruct the ventilation holes of the cylinder housing.
  • Do not move the appliance when in opera-tion.
  • Shut off the valve at the gas cylinder and/or the regulator:
  • a. before moving the appliance
  • b. after use
  • The tubing or the flexible hose must be changed within the prescribed intervals
  • Use only the type of gas and the type of cylinder specified by the manufacturer
  • In case of violent wind particular attention must be taken against tilting of the appli-ance
  • Have any repairs and/or maintenance car-ried out by a recognized service engineer only
  • Make sure that the correct gas is used and that the gas containers are not exposed to heat or extreme temperature changes.
  • Always store the gas containers in a cool, dry and dark place.
  • Always use a suitable and approved 700 mbar medium-pressure regulator. In case of any doubt contact your local dealer.

ASSEMBLING THE HEATER

  • The manufacturer is not responsible for any harm or damage if attention is not paid to the points described above.
  • The use of this product and the elements required for that purpose is entirely at the end user’s own risk.

GFA1015 BAFFLE INSTALLATION INTRODUCTION

  • To protect your floor ALWAYS mount the baffle to the front outlet of the heater.
  1. 1. Take out of the heater from the box. The baffle is installed under the air-output as below arrow part
  2. Anti-clockwise unscrew the 2 screws for the baffle.
  3. Install the baffle as below picture.
  4. Clockwise tighten the 2 screws.
  5. Finished status
GAS REQUIREMENTS

Use propane, butane or LGP only. See rating label on the appliance.

  • The appliance requires approved gas hose in <150 cm length and a gas regulator. The hose and regulator assembly must conform to local standard codes.
  • Regulator maximum inlet pressure must not exceed 690 kPa
  • Gas connection 1/4’’ LH. To be used with 700 mbar regulator
  • Gas connection 3/8 LH. To be used with 0-2 bar regulator
  • The installation must conform to local codes, or in the absence of local codes, to the standard for the storage and handling of liquid petroleum gases.
  • A dented, rusted or damaged gas cylinder may be hazardous and should be checked by an authorized dedicated gas specialist,
  • Never use a gas cylinder with a damaged valve connection.
  • The gas cylinder must be arranged to provide for vapor withdrawal from the operating cylinder.
  • Never twist the flexible tubes and hoses.
  • Never connect an unregulated gas cylinder to the heater.
  • Disconnect the gas cylinder when the heater is not use.

LEAK TESTING

  • Gas connections on the heater are leak tested at the factory prior to ship-ment. A complete gas tightness check must be performed at the installation site due to possible mishandling in shipment and/or installation or because of excessive pressure being applied to the heater. The heater must be chec-ked with a full cylinder.
  1. Make sure the safety control valve is in the OFF position.
  2. Make a soapy water solution of one part liquid detergent and one part water. The soapy water solution can be applied with a spray bottle, brush or rag to all gas connections. Soap bubbles will appear in case of a Ieak.
  • WARNING: Never leak test while smoking!
  • WARNING : In the event of gas leakage, the appliance shall not be used or if alight, the gas supply shall be shut off and the appliance shall be investiga-ted and rectified before it is used again.
  1. Turn the gas supply ON. And check all the connections with the soapy water solution. No bubbles may appear!
  2. In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn the gas supply ON and recheck. Contact your dealer or gas supplier for assistance if bubbles continue to appear.

Note:

  • The gas hose is NOT included with the heater
  • The gas regulator is not included with the heater
  • Connect the regulator to the gas cylinder (not included) according to the mounting instruction as supplied together with the gas regulator and/or the gas cilinder

OPERATION

Safe operation

This appliance is designed for gas cylinders up to 15 kg
Avoid torsional stress to the flexible tubing between gas regulator and appliance. Torsional stress might lead to gas leakage over time!
Note:
If a new tank has just been connected, please allow at least one minute or more for the air in the gas pipeline to purge out through the pilot hole.
If the burner flame goes out accidentally or it is blown out by wind, turn off the heater and wait at Ieast 5 minutes or more to let the gas dissipate before re-ligh-ting to avoid possible gas explosion.
Warnings:

  • The whole gas system. hose, regulator, pilot and burner should be inspected for Ieak before use. But at least once a month and each time the gas cylinder is changed. Check the hose assembly for sign of extreme abrasion, cuts or wears. Suspected areas should be Ieak tested. If the hose Ieaks, it must be replaced with a new one that conforms to IocaI standard codes. ). If it shows signs of cracking, splitting or other deterioration it shall be exchanged for new hose of the same length and of the equivalent quality.
  • Always keep a dry chemical fire extinguisher readily available.
  • For safety, always allow a 5-minute complete shut off period before re-ligh-ting a hot heater.
  • Replace the gas tube/hose within the interval described with the hose.

REPLACING THE GAS CYLINDER

  • Shut off heater.
  • Close the valve of the gas cylinder.
  • Disconnect the regulator from the cylinder following the instructions that came with your regulator.
  • Replace the cylinder.
  • Make sure there is no flame. Only when no flame: remove the plug or seal cap from the cylinder valve.
  • Check for the presence and good state of the gasket before connecting the regulator to the new cylinder
  • Check that the regulator seal is correctly fitted and able to fulfil its function.
  • Perform leak test using soapy water solution.

WARNING : only change the gas cylinder in a amply ventilated area, away from any ignition source (candle, cigarettes, other flame producing applian- ces, …).

SAFETY CLEARANCE

  • For every kW it is necessary to have permanent ventilation of 25 cm², equally distributed between the floor and high level, with a minimum outlet of 250 cm².
  • Never direct the hot air flow towards the cylinder.
  • Never use the heater without its cover.
  • Do not exceed 100 W/m³ of free room. The minimum volume of the room must be larger than 100 m³.
  • Do not obstruct the inlet or outlet sections of the heater.
  • If the heater has to work for a long period at its maximum capacity, it’s possi-ble that ice will form on the cylinder. This is due to excessive vapour withdra-wal. Not for this reason, or for any other, should the cylinder be heated. To avoid this effect, or at least to reduce it, use a large cylinder or two cylinders linked together (Fig 1).
  • Do not use the heater in cellars, basements or in any room below the ground level.
  • After use, turn the gas cylinder tap off.
  • The gas bottle must always be replaced following safety rules away from any possible source of ignition.
  • The heater must be placed where there is no risk of fire, the hot air outlet must be at least 3m from any flammable wall or ceiling and must never be directed towards the gas bottle.
  • If in any doubt contact your supplier.

INSTALLATION

  1. Connect the heater to a suitable electric socket /230V~50Hz
  2. Make sure that the machine is properly earthed.
  3. Connect the gas supply hose to the pressure regulator and connect the regu-lator to a suitable LPG cylinder.
  4. Open the tap of the cylinder and check the supply hose and fittings for gas leak. For this operation it is recommended to use an approved leak detector.

INSTRUCTION FOR USE

PREPARING FOR OPERATION

  1. Check the heater for possible shipping damage.
  2. Connect the hose and regulator assembly to the LPG cylinder.
  3. Open the cylinder’s gas valve and check all gas connections with a soap and water solution.
  4. Connect power cord to well-grounded 220V~, 50Hz source of power.Qlima-GFA-1010-Gas-Heater-FIG-1

IGNITION / Manual ignition

  1. Turn the power switch to position I and check that the fan starts running cor-rectly.
  2. Push the gas valve button and push repeatedly (!!) the ignitor (piezoelectric lighter) until the flame lights up.
  3. As the flame lights up, keep the valve button pushed for 10 seconds approx. Should the heater stop when the valve button has been released, wait one minute and repeat the starting operation keeping the valve button pushed for a longer time.
  4. Contact your supplier should any problem continue.Qlima-GFA-1010-Gas-Heater-FIG-7

CAUTION
If ignition is difficult or irregular before repeating the ignition operations make sure that the fan is not locked and the air inlet and outlet are unobstructed.
SWITCH OFF
To stop the heater, shut off the gas cylinder tap. Let the fan run until the flame shuts down and then turn the fan switch to position O.
AIR CONDITIONING

  1. The heater can also be used as a ventilator.
  2. In this case remove the gas supply hose and connect the plug of heater to a suitable electrical supply.
  3. Set the fan switch to position I.

ODOR FADE WARNING

Asphyxiation Hazard

  1. Do not use heater for heating human quarters.
  2. Do not use in unventilated areas.
  3. The flow of combustion and ventilation air must not be obstructed.
  4. Proper ventilation air must be provided to support the combustion air requi-rements of the heater being used.
  5. Lack of proper ventilation air will lead to improper combustion.
  6. Improper combustion can lead to carbon monoxide poisoning leading to serious injury or death. Symptom of carbon monoxide poisoning can include headaches dizziness and difficulty in breathing.

FUEL GAS ODOR

LP gas and natural gas have manmade odorants added specifically for the detection of fuel gas leaks.
If a gas leak occurs you should be able to smell the fuel gas. Since Propane (LP) is heavier than air you should smell for the gas odor low to the floor. ANY GAS OROR IS YOUR SIGNAL TO GO INTO IMMEDIATE ACTION?

  1. Do not take any action that could ignite the fuel gas. Do not operate any electrical switches. Do not pull any power supply or extension cords. Do not light matches or any other source of flame. Do not use your telephone.
  2. Get everyone out of the building and away from the area immediately.
  3. Close all propane (LP) gas tank or cylinder fuel supply valves.
  4. Propane (LP) gas is heavier than air and may settle in low areas. When you have reason to suspect a propane leak, keep out of all low areas.
  5. Use your neighbor’s phone and call your fuel gas supplier and your fire department. Do not reenter the building or area.
  6. Stay out of the building and away from the area from the area until declare safe by the firefighters and your fuel gas supplier.
  7. FINALLY, let the fuel gas service person and the firefighters check for escaped gas. Have them air out the building and area before you return. Properly trained service people must repair any leaks, check for further leakages, and then relight the appliance for you.

MAINTENANCE

  1. The repairs or maintenance operations must only be carried out by qualified personnel.
  2. The unit must be checked by a qualified technician at least once a year.
  3. Regularly check the conditions of gas hose, and gas regulator if it must be replaced only use original spare parts.
  4. Before starting any maintenance operation on the heater disconnect from both gas and electrical suppliers.
  5. If the unit has not been used for a long period we advise that a technician carries out a general check up before using. It is important to control the fol-lowing:
  • Periodically check the gas supply hose conditions and, should it be changed, use only original spare parts.
  • Check the starting electrode position (Pic 1)
  • Check the connections of the safety thermostat and of the thermocouple: they must always be clean.
  • If necessary clean the fan blade and the inside of the heater using compres-sed air.

STORAGE

  • Make sure the heater is in off position
  • Always close the valve of the gas cylinder after use or in case of a disturban-ce.
  • Disconnect the gas container from the gas heater.
  • Store the gas container in a well-ventilated room. Position it far away from inflammable, explosive or hot materials and preferably not in the home. In addition it should never be stored in the basement or attic.
  • Cylinder must be stored out of the reach of children.
  • Disconnected cylinder must have threaded valve plugs tightly installed and must not be stored in garage or any other enclosed area. Only store in venti-lated area!
  • Storage of heater indoors is permissible only if the cylinder is disconnected and removed from the heater.
  • Check the tightness of the gas valve and for damage. If you suspect a dama-ge, have it changed by your gas dealer.
  • Never store liquid gas cylinder in a sub-terrain, or at places without adequate air ventilation.

CLEANING AND CARE

  • Warning: Make sure the heater is in off position and is cool!
  • Warning: Do not clean heater with cleaners that are combustible or corrosive.
  • Wipe off powder coated surfaces with soft, moist rag and soap water.
  • Remove debris, spider and insect nests from ventilation opening of the cylin-der enclosure, control compartment, burner and circulation air passageways of the heater with heavy duty pipe cleaner or compressed air to keep appli-ance clean and safe for use.
  • Never clear ports or other openings with toothpicks or other article that will break and block the ports.

TROUBLESHOOTING

Qlima-GFA-1010-Gas-Heater-FIG-9

END OF LIFETIME

If it is decided that the gas heater is not to be used any more, it is recommended that it be disconnected from the gas container. Also cut the rubber hose. If children play with the heater, make sure that dangerous parts are removed. Never dispose of non-biodegradable products in the environment, but dispose of them in accordance with current national legislation. At the end of its lifetime, the product must not be disposed of as urban waste. It must be taken to a special local authority differentiated waste collection center or to a dealer providing this service. Disposing of a household appliance separately avoids possible negative consequences for the environment and health deriving from inappropriate disposal and enables the constituent materials to be recovered in order to make significant savings in energy and resources. As a reminder of the need to dispose of household appliances separately.

WARRANTY PROVISIONS

The appliance is supplied with a 24-month guarantee, commencing on the date of purchase. All material and manufacturing defects will be repaired or replaced free of charge within this period. The following rules apply:

  1. We expressly refuse all further damage claims, including claims for collateral and/or consequential damage.
  2. Repairs to or replacement of components within the guarantee period will not result in an extension of the guarantee.
  3. The guarantee is invalidated if any modifications have been made, non-genuine parts are fitted or repairs are carried out by third parties.
  4. Components subject to normal wear, such as filters, batteries, lamps and heating elements are not covered by the guarantee.
  5. The guarantee is valid only when you present the original, dated purchase invoice and if no modifications have been made to it.
  6. The guarantee is invalid for damage caused by neglect and/or by actions that deviate from those in this instruction booklet.
  7. Transportation costs and the risks involved during the transportation of the appliance or components of the appliance shall always be for the account of the purchaser
  8. Damage caused by not using suitable spare parts is not covered by the guarantee.
  9. To prevent unnecessary expense, we recommend that you always first carefully consult the instructions for use. Take the appliance to your dealer for repairs if these instructions do not provide a solution. www.Qlima.com
  • If you need information or if you have a problem, please visit our website (www.qlima.com) or contact our sales support (T: +31 412 694694)

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals