PERFORMANCE
Model | HP | GPH of Water @ Total Feet Of Lift | Max. Lift |
---|---|---|---|
0 ft. | 5 ft. | 10 ft. | 15 ft. |
SPS05004TPK | 1/2 | 3600 | 2880 |
SAFETY INSTRUCTIONS
- Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the presence of flammable or explosive vapors. Using this pump with or near flammable liquids can cause an explosion or fire, resulting in property damage, serious personal injury, and/or death.
- ALWAYS disconnect the power to the pump before servicing.
- Do not touch the motor housing during operation. The motor is designed to operate at high temperatures. Do not disassemble the motor housing.
- Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface, or in water before disconnect the power.
- Release all pressure and drain all water from the system before servicing any component.
- Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing personal injury, and/or property damage.
- Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present a life threatening safety hazard if the insulation becomes damaged or the connection ends fall into water. The use of an extension cord to power this pump is not permitted.
- Wear safety goggles at all times when working with pumps.
- This unit is designed only for use on 115 volts (single phase), 60 Hz, and is equipped with an approved 3-conductor cord and 3-prong grounded plug. Do not remove the ground pin under any circumstances. The 3-prong plug must be directly inserted into a properly installed and grounded 3-prong, grounding-type receptacle. Do not use this pump with a 2-prong wall outlet. Replace the 2-prong outlet with a properly grounded 3-prong receptacle (a GFCI outlet) installed in accordance with the National Electrical Code and local codes and ordinances. All wiring should be performed by a qualified electrician.
- Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not use damaged or worn cords.
- Failure to comply with the instruction and designed operation of this unit may void the warranty. ATTEMPTING TO USE ADAMAGED PUMP can result in property damage, serious personal injury, and/or death.
- Ensure that the electrical circuit to the pump is protected by a 15 Amp fuse or circuit breaker.
- Do not lift the pump by the power cord.
- Know the pump and its applications, limitations, and potential hazards.
- Secure the pump to a solid base. This will aid in keeping the pump in a vertical orientation. This is critical in keeping the pump operating at maximum efficiency. It will also help prevent the pump from clogging resulting in premature failure.
- Periodically inspect the pump and system components to ensure the pump suction screen is free of mud, sand, and debris. Disconnect the pump from the power supply before inspecting.
- Follow all local electrical and safety codes, along with the National Electrical Code (NEC). In addition, all Occupational Safety and Health Administration (OSHA) guidelines must be followed.
- The motor of this pump has a thermal protector that will trip if the motor becomes too hot. The protector will reset itself once the motor cools down and an acceptable temperature has been reached. The pump may start unexpectedly if it is plugged in.
- Ensure the electrical power source is adequate for the requirements of the pump.
- This pump is made of high-strength, corrosion-resistant materials. It will provide trouble-free service for a long time when properly installed, maintained, and used. However, inadequate electrical power to the pump, dirt, or debris may cause the pump to fail. Please carefully read the manual and follow the instructions regarding common pump problems and remedies.
PRE-INSTALLATION
APPLICATION
-
This submersible sump pump is designed for home sump applications. Use this pump only for pumping water.
-
This unit is not designed as a waterfall or fountain pump, or for applications involving salt water or brine! Use with
waterfalls, fountains, salt water or brine will void warranty. -
Do not use where water recirculates.
-
Not designed for use as a swimming pool drainer.
TOOLS REQUIRED
-
Flathead Screwdriver
-
Phillips Screwdrive
-
Channel Locks
-
Pipe wrench
-
Hacksaw
-
Cable Ties
-
Safety goggles
-
Tape Measure
MATERIALS REQUIRED (NOT INCLUDED)
NOTE: Parts shown below not to scale.
-
1-1/4’’ PVC Threaded adapter (Pipe to Pump)
-
1-1/4’’ ABS or PVC Pipe
-
Thread Tape
-
1-1/4” check valve
-
ABS or PVC Cement (to match the pipe)
-
1-1/4” 90° Elbow
SPECIFICATIONS
Power supply | 115V, 60 HZ., 15 Amp Circuit |
---|---|
Liquid temp. range | 32°F to 95°F (0°- 35°C) |
Discharge size | 1-1/4 in. MNPT or 1-1/4 in. FNPT (with adaptor) |
Sump basin | Min. 14 in. (356 mm) diameter, 18 in. (457 mm) depth |
INSTALLATION
-
Install the pump in sump pit with minimum diameter of 14in.(356mm). The sump depth should be 18 in. (457 mm). Construct the sump pit of tile, concrete, steel or plastic. Check local codes for approved materials and for proper installation.
-
Install the pump in a pit so that the switch operating mechanism has maximum possible clearance.
-
The pump should not be installed on clay, earth or sand surfaces. Clean the sump pit of small stones and gravel which could clog the pump. Keep the pump inlet screen clear.
NOTE: Do not use ordinary pipe joint compound on plastic pipe. Pipe joint compound can attack plastics. -
Connect 90°elbow to the pump outlet. Install discharge plumbing. Use rigid plastic pipe and wrap threads with PTFE pipe thread sealant tape. Screw pipe into the pump hand tight plus 1-1/2 turns.
CAUTION: Risk of flooding. Can cause personal injury and/or property damage. If a flexible discharge hose is used, make sure the pump is secured in the sump to prevent movement. Failure to secure the pump may allow pump movement, switch interference and prevent the pump from starting or stopping. -
To reduce motor noise and vibrations, a short length of rubber hose (1-7/8 in. (47.6 mm) I.D., e.g. radiator hose) can be connected into the discharge line near the pump using suitable clamps.
-
Install an in-line check valve or an in-pump check valve to prevent flow backwards through the pump when the pump shuts off.
NOTE: If your check valve is not equipped with an air bleed hole to prevent air locking the pump, drill a 1/8 in. (3.2 mm) hole in the discharge pipe just above where the discharge pipe screws into the pump discharge. Be sure the hole is below the waterline and the check valve to prevent air locks. -
Power Supply: Pump is designed for 115 V, 60 Hz, operation and requires a minimum 15 amp individual branch circuit. Plug the pump power cord plug into the piggyback switch plug outlet, and then plug the switch plug into a 115V GFCI power outlet for automatic operation. The pump will start operating if the float switch moves over the pump top. The water will be pumped out. When the water lowers to certain level, the float switch will turns off the pump.
Or plug the pump power cord plug into a 115V GFCI power outlet directly for manual operation. Pump will start operating immediately once it plug to the GFCI and drain water out, when the water moved
out, you must unplug the pump immediately.
The following picture shows a typical connection for pumps with the piggy-back plug, for manual and automatic operations. Automatic – Plug float cord into GFCI outlet, then plug pump cord into float cord.
Manual – Plug pump cord directly into GFI outlet
WARNING: Risk of electric shock. Can shock, burn or kill. Pump should always be electrically grounded to a suitable electrical ground such as a grounded water pipe or a properly grounded metallic raceway, or ground wire system. Do not cut off the round ground pin. -
If the pump discharge line is exposed to outside subfreezing atmosphere, a portion of line exposed must be installed so any water remaining in the pipe will drain to the outfall by gravity. Failure to do this can cause water trapped in the discharge to freeze which could result in damage to the pump.
-
After the piping and check valve have been installed, the unit is ready for operation.
-
Check the pump operation by filling the sump with water and observing pump operation through one complete cycle.
CAUTION : Risk of flooding. Can cause personal injury and/or property damage. Failure to make this operational check may lead to improper operation, premature failure, and flooding.
OPERATION
WARNING: Risk of electric shock. Can shock, burn or kill. Do not handle a pump or pump motor with wet hands or when standing on a wet or damp surface, or in water.
- The shaft seal depends on water for lubrication. Do not operate the pump unless it is submerged in water as the seal may be damaged if allowed to run dry.
- The motor is equipped with an automatic reset thermal protector. If temperature in the motor should rise unduly, the switch will cut off all power before damage can be done to the motor. When the motor has cooled sufficiently, the switch will reset automatically and restart the motor. If the protector trips repeatedly, the pump should be removed and checked. Low voltage, long extension cords, clogged impeller, very low head or lift, or a plugged or frozen discharge pipe, etc., could cause the protector to trip.
- The pump will not remove all water. If operating a pump manually, and suddenly no water comes out of the discharge hose, shut off the unit immediately. The water level is probably very low and the unit has broken prime.
WARNING: Risk of electric shock. Can shock, burn or kill. Before
attempting to check why the unit has stopped operating, disconnect power from
the unit.
CAUTION: Do Not Change the preset tether length.
CARE AND CLEANING
CAUTION: Always use the handle to lift the pump. Never use the power cord to lift the pump. To avoid skin burns, unplug the pump and allow time for it to cool after periods of extended use.
Do
- When the power is disconnected, inspect the pump suction screen and remove all debris, then plug the pump back into the grounded (GFCI) outlet.
Do Not
- Do not disassemble the motor housing. This motor has NO repairable internal parts, and disassembly may cause leakage or dangerous electrical wiring issues.
- Do not lift up the pump by the power c
To clean a pump clogged with debris:
- Unplug the pump from electrical power.
- Unscrew the stainless screws, and remove the volute/bottom seal plate.
- Unscrew the stainless screws, and remove the diffuser.
- Use a flathead screwdriver to hold the shaft, then turn the impeller counterclockwise to release the impeller.
- Remove debris from around the shaft and on/under the impeller.
- Reassemble the pump.
TROUBLESHOOTING
Problem | Possible Cause | Corrective Action |
---|---|---|
The pump does not start or run. | 1. The fuse is blown.2. The breaker |
is tripped.3. The plug is disconnected.4. The plug is corroded.5.
There is thermal overload.6. The switch failed.7. The motor failed.|
1. Replace the fuse.2. Reset the breaker.3. Secure the plug.4.
Clean the plug prongs.5. Unplug for 30 minutes and then plug in again.6.
Replace the switch.7. Replace the pump.
The pump operates but pumps little or no water.| 1. The screen is
blocked.2. Debris is caught in the impeller or discharge.3. The
impeller is loose on the shaft or the impeller is broken.| 1. Clean the
screen.2. Remove the debris. 3. Reassemble the impeller or
replace the impeller.
The pump starts and stops too often.| 1. There is a backflow of water from
the piping or the check valve is leaking.2. The float switch is stuck.| 1.
Install a check valve or replace the check valve.2. Clean the float switch
to make sure the float moves up and down freely.
The pump will not shut off.| 1. The switch is tangled. 2. The
float switch is faulty.3. The float is obstructed.| 1. Reposition the
pump and make sure the switch moves freely.2. Replace the switch.3.
Remove the obstruction.
WARRANTY
K2 Pumps Limited Warranty
WHAT THIS WARRANTY COVERS
This Limited Warranty is effective September 1, 2020 and replaces all undated warranties dated prior to September 1, 2020.
K2 Pumps (K2) warrants to the original consumer purchaser (You) that its products are free from original defects in material and workmanship for at least one year (warranty varies depending on model; see box or K2 website for specific warranty information) from the date of purchase (the Warranty Period). Repair Parts and Accessories are warranted for 90 days from the date of purchase. During the Warranty Period, K2 will repair or replace, at no cost to you, products that have been examined by K2 and found to be defective in materials or workmanship.
Do not return product to the retail store.
For technical support and parts, call K2 Customer Service at
844-242-2475.
WHAT THIS WARRANTY DOES NOT COVER
This Warranty does not cover use of the product in a non-residential
application, improper installation and/or maintenance of the product, damage
due to misuse, acts of God, nature, vandalism or other acts beyond control of
K2, owner’s acts or omissions, use outside the country in which the product
was initially purchased and resale of the product by the original owner. This
warranty does not cover pick up, delivery, transportation or house calls.
However, if you mail your product to a K2 Sales and Service Center for
warranty service, cost of shipping will be paid one way. This warranty does
not apply to products purchased outside of the United States, including its
territories and possessions, outside of U.S. Military Exchange and outside of
Canada. This warranty does not cover products purchased from a party that is
not an authorized retailer, dealer or distributor of K2 products.
OTHER IMPORTANT TERMS
This warranty is not transferable and may not be assigned. This Warranty shall
be governed and construed under laws of the state of Michigan. The Warranty
Period will not be extended by any replacement or repair performed under this
Warranty. THIS WARRANTY IS THE EXCLUSIVE WARRANTY AND REMEDY PROVIDED BY K2.
ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OR
MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE, ARE DISCLAIMED. IN NO EVENT
WILL K2 BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL
DAMAGES OF ANY KIND OR NATURE TO OWNER OR ANY PARTY CLAIMING THROUGH OWNER
WHETHER BASED IN CONTRACT, NEGLIGENCE, TORT, OR STRICT PRODUCTS LIABLITY OR
ARISING FROM ANY CAUSE WHATSOEVER. Some states do not allow for the exclusion
of consequential damages, so the above exclusion may not apply to you. This
warranty gives you specific rights. You may also have other rights that vary
from state to state.
GP Enterprises Co., Ltd. 1436 Brook Drive, Downers Grove, IL 60515
Phone:844-242-2475 / Web:
www.K2Pumps.com
2 For Professional Technical Support call 1-844-242-2475
References