Honeywell Voyager XP 1470g Series Corded Area-Imaging Scanner User Guide
- June 4, 2024
- Honeywell
Table of Contents
Honeywell Voyager XP 1470g Series Corded Area-Imaging Scanner
Agency Model: 1470g
Note: Refer to your User Guide for information about cleaning your
device.
Getting Started
Turn off computer’s power before connecting the scanner, then power up the computer once the scanner is fully connected.
Power Supply Assembly (if included)
Connecting the Scanner
USB
Keyboard Wedge:
RS232 Serial Port:
RS485:
Reading Techniques
The view finder projects an aiming dot that should be centered over the bar
code, but it can be positioned in any direction for a good read.
Hold the scanner over the bar code, press the button, and center the aiming
dot on the bar code.
The aiming dot is smaller when the scanner is closer to the code and larger
when it is farther from the code. Hold the scanner close to smaller bar codes,
and farther away from large bar codes to get a proper read.
If the bar code is highly reflective (e.g., laminated), you may need to tilt the scanner at an angle so the bar code can be scanned.
Standard Product Defaults
The following bar code resets all standard product default settings.
Note: PDF and 2D bar codes can only be read by Voyager model 1470g2D and cannot be read by model 1470g1D.
RS485 Interface
The RS485 interface defaults to port 5B. If you have an IBM POS terminal using
port 9B, scan the appropriate code below to program the terminal, then power
cycle the cash register.
Note: For additional RS485 interface selections, see the User Guide for your product.
Keyboard Country
Scan the appropriate country code that follows to program the keyboard layout
for your country or language. By default, national character replacements are
used for the following characters: # $ @ [ ] \ | ^ ‘ { } ~
Refer to the ISO 646 Character Replacements chart in your User Guide to view
the character replacements for each country.
Note: For a complete list of country codes, see the User Guide for your product.
Trigger
The following bar codes will allow you to use the scanner in Manual Trigger –
Normal Mode (need to press the button to read) or Presentation mode (the
scanner is activated when it “sees” a bar code).
Suffix
If you want a carriage return after the bar code, scan the Add CR Suffix bar
code. To add a tab after the bar code, scan the Add Tab Suffix bar code.
Otherwise, scan the Remove Suffix bar
code to remove the suffixes.
Add Code ID Prefix to all Symbologies
Scan the following bar code if you wish to add a Code ID prefix to all
symbologies at once.
Note: For a complete list of Code IDs, see the User Guide for your product.
Function Code Transmit
When this selection is enabled and function codes are contained within the
scanned data, the scanner transmits the function code to the terminal. Charts
of these function codes are provided in your User Guide. When the scanner is
in key-board wedge mode, the scan code is converted to a key code
before it is transmitted.
Data Format Editor Instructions
The following are abbreviated instructions for entering a data format. For
complete instructions refer to your User Guide.
- Step 1. Scan the Enter Data Format symbol.
- Step 2. Primary/Alternate Format: scan 0 for Primary Format
- Step 3. Terminal Type: scan 099 for any terminal type
- Step 4. Code I.D.: scan 99 for any bar code type
- Step 5. Length: scan 9999 for any length bar code.
- Step 6. Editor commands: use the Programming Chart that follows.
- Step 7. Scan Save to save your entries.
Programming Chart
EZConfig for Scanning
To access additional features for the scanner, use
EZConfig for Scanning, an online configuration software tool, available from
our website.
Support
To search our knowledge base for a solution or to log into the Technical Support portal and report a problem, go to www.hsmcontactsupport.com.
Documentation
Product documentation is available at
www.honeywellaidc.com.
Limited Warranty
For warranty information, go to www.honeywellaidc.com and click Get Resources
Product Warranty.
Patents
For patent information, see www.hsmpats.com.
Disclaimer
Honeywell International Inc. (“HII”) reserves the right to make changes in
specifications and other information contained in this document without prior
notice, and the reader should in all cases consult HII to determine whether
any such changes have been made. The information in this publication does not
represent a commitment on the part of HII.
HII shall not be liable for technical or editorial errors or omissions
contained herein; nor for incidental or consequential damages resulting from
the furnishing, performance, or use of this material. HII disclaims all
responsibility for the selection and use of software and/or hardware to
achieve intended results.
This document contains proprietary information that is protected by copyright.
All rights are reserved. No part of this document may be photocopied,
reproduced, or translated into another language without the prior written
consent of HII.
Copyright 2019 Honeywell International Inc. All rights reserved.
References
- Safety and Productivity Solutions | Honeywell
- Productivity products and associated patents | Honeywell
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>