RAB FA 40-60W Field Adjustable Wall Pack Instruction Manual
- June 9, 2024
- RAB
Table of Contents
RAB FA 40-60W Field Adjustable Wall Pack
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE
REFERENCE.
RAB fixtures must be wired in accordance with the National Electrical Code and
all applicable local codes. Proper grounding is required for safety. THIS
PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE
BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND
THE HAZARDS INVOLVED.
Min 90 °C SUPPLY CONDUCTORS.
WARNING: Make certain power is OFF before installing or maintaining
fixture. No user serviceable parts inside.
WARNING: Do not use an electric generator to test LED fixtures.
CAUTION: For proper weatherproofing function, all gaskets must be seated
properly and all screws inserted and tightened. This is important with an
uneven wall surface. Silicone all plugs and unused conduit entries.
For wet location compliance, fixture must be properly sealed. For moisture
seal, apply silicone caulking between the mounting surface and back housing,
as well as around the sides of the housing. This is important with uneven wall
surface.
WALL MOUNT
Suitable for outdoor applications.
-
Using a screwdriver loosen side Housing Screws (2) .
-
Remove the Housing Back Plate and unscrew center Plug, using a drill open installation holes in Housing Back Plate.
-
Apply Foam Gasket (provided) to external surface of the Housing Back Plate by removing yellow plastic film and adhering to Housing Back Plate
-
Feed supply wires through Housing Back Plate .
Wire the Housing leads to supply wires using UL listed wire connectors according to NEC and local codes .Push all wires into the Housing. -
Secure Housing Back Plate to surface or junction box (supplied by others) with Screws (supplied by others) .
-
Mount the Housing over the Housing Back Plate and secure with (2) Screws (provided) .
-
For Conduit wiring, remove Side Conduit Cap using a screwdriver. Feed supply wires through conduit opening with a suitable connector. Wire the Housing leads to supply wires using UL listed wire connectors according to NEC and local codes. Push all wires into the Housing. Follow mounting instructions.
FIELD ADJUSTMENT
Follow instructions below to change fixture Color Temperature (CCT) from the
factory settings and Photocell On/Off option.
Factory Settings: 4000K
- Locate the Color Temperature (CCT) and Photocell On/Off switches on the side of Housing .
- Select Color Temperature (CCT) and Photocell On/Off position by sliding the respective switches to the desired value.
0-10V DIMMABLE WIRING
Universal voltage driver permits operation at 120V thru 277V, 50 or 60 Hz. For 0-10 Dimming, follow the wiring directions as in Fig. 8.
- Connect the Black/Brown fixture lead to the LINE supply lead.
- Connect the White/Blue fixture lead to the COMMON supply lead.
- Connect the Green/Yellow wire from the fixture to supply ground. Do NOT connect GROUND of the dimming fixture to the output.
- Connect the purple fixture lead to the DIM V+ lead.
- Connect the gray fixture lead to the DIM V- lead.
- Cap the yellow fixture lead, if present. Do NOT connect.
CLEANING & MAINTENANCE
CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized.
- Clean polycarbonate lens with non-abrasive glass cleaning solution.
- Do not open the fixture to clean the LED. Do not touch the LED.
TROUBLESHOOTING
- Is the fixture grounded properly?
- It is recommended to wear gloves to avoid injury during installation.
- If any smoke or spark, please turn off the power immediately.
Note: These instructions do not cover all details or variations in
equipment nor do they provide for every possible situation during
installation, operation or maintenance.
rablighting.com
Visit our website for product info
Tech Help Line
Call our experts: 888 722-1000
e-mail
Answered promptly – sales@rablighting.com
Free Lighting Layouts Answered online or by request
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>