3M Particulate Respirator 9623 Mask Instructions
- June 8, 2024
- 3M
Table of Contents
3M Particulate Respirator 9623 Mask
FEATURES
| Household Dust
---|---
| Dust Mite Debris
| Airborne Pollen
| Pet Dander
| Cough & Sneeze Debris
| Airborne Particles
SYMBOLS
Particulate Respirator 9623|
0598
|
0120
---|---|---
EN149:2001+A1:2009| EN149:2001+A1:2009
FFP2 NR| FFP2 NR
| Your attention please
---|---
| Instructions for Use
| End of Shelf Life
| Temperature Range
| Max. relative humidity
| Legal Manufacturer
| Contact Address
| Non Reusable
Please keep these user instructions for reference. NR = Non Reusable (up to 8
hours). This product is approved and audited by SGS FIMKO OY Takomotie 8 00380
HELSINKI Finland. EU Notified Body No. 0598.
This product meets the requirements of Regulation EU 2016/425 and applicable
local legislation, which can be determined by reviewing the certificate and
declaration of conformity at www.3M.com/9623FFP2. This product is approved and
audited by SGS United Kingdom Ltd Rossmore Business Park, Ellesmere Port,
South Wirral, Cheshire CH65 3EN, UNITED KINGDOM. Notified Body No. 0120. This
product meets the requirements of Personal Protection Equipment Regulation
2016/425 as brought into UK law and amended. Review the certificate and
declaration of conformity at www.3M.com/9623FFP2. Designed for consumer use.
Not intended for professional use. For workplace use, follow all national
requirements including respirator face fit testing. Certification authority:
This product meets the requirements of EN149:2001+A1:2009, filtering facepiece
respirators for use against particles. When used as instructed, this product
can help reduce the number of inhaled particles according to the FFP2
performance classification.
FFP2 NR – Filter media filters ≥ 94% of airborne particulate matter as per
EN149:2001+A1:2009.
This respirator can help reduce inhalation exposure to certain airborne
particles, such as household dust, dust mite, pollen, pet dander, cough/sneeze
particles, and other airborne particulate matter, when used as instructed.
Warning and Limitations: Do NOT Use For: This respirator cannot be used for respiratory protection against gaseous pollutants, cannot be used in oxygen deficiency, unknown pollutants or concentration exceeding immediate dangerous to life and health environment. Not recommended for industrial workplace applications. NR = Non reusable (up to 8 hours).
Warning: This product can only be used for particulate respiratory protection. Respirators cannot stop the inhalation of all pollutants or contaminants in the air and do not eliminate the risk of contracting infection, illness or disease. Misuse may cause injury, severe or life threatening illness. For proper use and application, please read all information, including these User Instructions and on the package. Device must be protected from damage during transportation
Product is not designed or intended for use by children.
Do not use without the hook. Must link the straps with hook when wearing the
respirator. People with chronic respiratory, cardiac or other medical
conditions that make breathing difficult should check with their healthcare
provider before using this respirator. Always follow all guidance from local
health authorities and regulatory agencies. Does not filter chemical vapors or
gases including ozone. Does not contain components made from natural rubber
latex
-
This product is intended for consumer use.
-
Follow all government guidance and requirements applicable for respiratory protection.
-
Before use, respirator user should read and understand product use instructions, making sure the product is suitable for the application and the respirator seals to the user’s face.
-
Before use, the user should inspect the product, making sure it is in good condition.
If damaged, dirty or difficult to breathe through, it should be replaced immediately. -
Do not use with facial hair, piercings, jewellery, clothing, or anything on the face that prevents full and direct contact of the respirator to the user’s skin. An improper seal will reduce protection and effectiveness of the respirator.
-
Before respirator is worn, user must conduct user facial seal check in accordance with “How To Use Instructions” wear method, making sure the respirator is worn properly.
-
CHOKING HAZARD – Small parts. Keep away from children and pets.
-
Wearing a respirator may cause breathing resistance. People with some cardiac and lung conditions/ diseases (including but not limited to asthma, heart conditions, or respiratory conditions) may not be suited for respirator use. If wearer has any questions about whether it is safe for them to use this product, they should check with their healthcare provider.
-
Use the respirator in accordance with User Instruction and warning information listed on the packaging.
If respirator is not worn during entire exposure to pollutants or contaminants in the air, the respiratory protection effect will be reduced, and may result in sickness or even death. -
If dizziness, allergy, or other symptoms of discomfort exist, please leave air pollution area at once and stop using the respirator.
-
Respirator must not be washed or altered.
-
When respirator is damaged, deformed, dirty or difficult to breathe through, please discard the respirator in an appropriate receptacle and replace with a new one.
-
Please keep respirator in a clean environment. Attention should be paid to keep it dry. Handle it in a way to avoid contaminating the inside of respirator. Before use, inspect the respirator to make sure it is in good condition.
-
Please keep unused respirator in its original package, store it away from dirt, dust, direct sun light exposure, high temperature/humidity and chemical environments. The shelf life of unused product is 5 years from the manufacture date when it is stored in temperature between -20°C and 30°C and humidity not over 80%RH. Manufacture date can be found on the package.
-
Respirators do not supply oxygen. Do not use in an oxygen-deficient atmosphere: use in well-ventilated areas.
-
Counterfeit check: if applicable, please refer to the authentication insert or check product packaging for authentication website and associated information. Follow all instructions to complete your product authentication process.
Dispose of used product in accordance with local regulations.
If you have questions, contact: 3M United Kingdom PLC, 3M Centre, Cain Road, Bracknell, Berkshire, RG12 8HT, +44 08705 360036.
HOW TO USE INSTRUCTIONS:
See Figure 1
- Open the respirator, then put it on so the foam and noseclip is across the bridge of nose. Ensure it covers the nose and chin.
- Pull each side band behind the head and attach with hook to secure the position.
- Press the nose clip toward your nose, then using the fingers of both hands, form the nose clip to the shape of the nose.
- To check for a proper seal: cover the respirator with both hands then breathe in quickly. Check for air leaking at the edges or at the nose position and if so, repeat steps 1-4.
Remember: Always follow these instructions. It is important to secure the side
bands using the hook and check for a proper seal when wearing the respirator.
Made in South Korea by 3M Korea Co., Ltd. 18, Jangan-gongdan 1gil, Jangan-
Myeon, Hwaseong-si, Gyeonggi-do, Republic of Korea. Lot number and Manufacture
Date (YYYYMMDD): See marking on the package. Expiration date: 5 years from
manufacture date.
3M is a trademark of 3M. © 2021 All rights reserved.
For suitability and proper use, follow local regulations and guidelines
including EN529 Standard, PPE Regulation (EU) 2016/425, and/or UK Regulation
2016/425 on PPE as brought into UK law and amended.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>