PWM -90 series

Features

  • Constant Voltage PWM style output
  • Emergency lighting application is available according to IEC61347-2-13
  • Built-in active PFC function and class II design
  • Class 2 power unit(except PWM-90-12)
  • No load power consumption <0.5W
  • Fully encapsulated with IP67 level
  • Function:3 in 1 dimming (dim-to-off); DALI/DALI-2
  • Minimum dimming level 0.2% for DALI type
  • Typical lifetime>50000 hours and 5 years warranty

Applications

  • LED strip lighting
  • Indoor LED lighting
  • LED decorative lighting
  • LED architecture lighting
  • Industrial lighting

Description

PWM-90 series is a 90W LED AC/DC LED driver featuring the constant voltage mode with PWM style output, which is able to maintain the brightness homogeneity when driving all kinds of LED strips. PWM-90 operates from 90~305VAC and offers models with different rated voltage ranging between 12V and 48V. Thanks to the high efficiency up to 90.5%, with the fanless design, the entire series is able to operate for -40C+85 C case temperature under free air convection. The entire series is rated with IP67 ingress protection level and is suitable to work for dry, damp or wet locations. PWM-90 is equipped with dimming function that varies the duty cycle of the output, providing great flexibility for LED strips applications.

Model Encoding

SPECIFICATION

DIMMING OPERATION

  • Apply one of the three methodologies between DIM+ and DIM-: 0 ~ 10VDC, or 10V PWM signal or resistance.
  • Dimming source current from power supply: 100μA (typ.)

Note :

  1. Min. duty cycle of output current is about 0.15%, and the dimming input is about 6KΩ or 0.6VDC, or 10V PWM signal with 6% duty cycle.
  2. The duty cycle of output current could drop down to 0% when dimming input is less than 6KΩ or less than 0.6VDC, or 10V PWM signal with duty cycle less than 6%.

DALI Interface (primary side; for DA/DA2-Type)

  • Apply DALI signal between DA+ and DA-.
  • DALI protocol comprises 16 groups and 64 addresses.
  • First step is fixed at 0.2% of output

OUTPUT LOAD vs TEMPERATURE

  • STATIC CHARACTERISTIC
  • POWER FACTOR (PF) CHARACTERISTIC

TOTAL HARMONIC DISTORTION (THD)

EFFICIENCY vs LOAD
PWM-90 series possess superior working efficiency that up to 90.5% can be reached in field applications.

LIFE TIME

**Block Diagram

**

Mechanical Specification

Recommend Mounting Direction

Installation Manual

Cautions

  • Before commencing any installation or maintenance work, please disconnect the power supply from the utility. Ensurethat it cannot be re-connected inadvertently!

  • Keep proper ventilation around the unit and do not stack any object on it. Also a 10-15 cm clearance must be kept when the adjacent device is a heat source.

  • Mounting orientations other than standard orientation or operate under high ambient temperature may increase the internal component temperature and will require a de-rating in output current.

  • Current rating of an approved primary /secondary cable should be greater than or equal to that of the unit. Please refer to its specification.

  • For LED drivers with waterproof connectors, verify that the linkage between the unit and the lighting fixture is
    tight so that water cannot intrude into the system.

  • For dimmable LED drivers, make sure that your dimming controller is capable of driving these units.PWM series require 0.15mA each unit.

  • Tc max. is identified on the product label. Please make sure that temperature of Tc point will not exceed limit.

  • DO NOT connect “DIM- to Vo-“.

  • Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minutes.

  • The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.