SAFETY INFORMATION
For your safety and correct operation of the appliance, read this manual
carefully before installation and use. Always keep these instructions with the
appliance even if you move or sell it. Users must fully know the operation and
safety features of the appliance.
The wire connection has to be done by specialized technician.
-
The manufacturer will not be held liable for any damages resulting from incorrect or improper installation.
-
The minimum safety distance between the cooker top and the extractor hood is 650 mm (some models can be installed at a lower height, please refer to the paragraphs on working dimensions and installation).
-
If the instructions for installation of the gas hob specify a greater distance, this must be respected.
-
Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood.
-
Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
-
For Class I appliances, check that the domestic power supply guarantees adequate earthing.
-
Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm. The route of the flue must be as short as possible.
-
Regulations concerning the discharge of air have to be fulfilled.
-
Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, etc.).
-
If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. When the cooker hood is used in conjunction with appliances supplied with energy other than electric, the negative pressure in the room must not exceed 0,04 mbar to prevent fumes being drawn back into the room by the cooker hood.
-
The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels.
-
If the supply cord is damaged, it must be replaced from the manufacturer or its service agent.
-
Connect the plug to a socket complying with current regulations, located in an accessible place.
-
With regards to the technical and safety measures to be adopted for fume discharging it is important to closely follow the regulations provided by the local authorities.
WARNING: Before installing the Hood, remove the protective films. -
Use only screws and small parts supplied with the hood.
WARNING: Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards. -
Do not look directly at the light through optical devices (binoculars, magnifying glasses…).
-
Do not flambè under the range hood; risk of fire.
-
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
-
Children should be supervised to ensure that they do not play with the appliance.
-
The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction.
Accessible parts may become hot when used with cooking appliances. -
Clean and/or replace the Filters after the specified time period (Fire hazard). See paragraph Care and Cleaning.
-
There shall be adequate ventilation of the room when the range hood is used at the same time as appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the room).
-
The symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product.
“In case of replacement with halogen lamp use only self-shielded tungsten halogen lamps or self-shielded metal halide lamps.”
CHARACTERISTICS
Dimensions
Components
Ref. | Q.ty | Product Components |
---|---|---|
1 | 1 | Hood Body, complete with: Controls, Light, Blower, Filters |
2 | 1 | Telescopic Chimney comprising: |
2.1 | 1 | Upper Section |
2.2 | 1 | Lower Section |
9 | 1 | Reducer Flange ø 150-120 mm |
10 | 1 | Adapting ring ø 120-125 mm |
15 | 1 | Air Outlet Connection |
Ref. | Q.ty | Installation Components |
7.2.1 | 2 | Upper Chimney Section Fixing Brackets |
11 | 6 | Wall Plugs |
12a | 6 | Screws 4.2 x 44,4 |
12c | 6 | Screws 2.9 x 9.5 |
16 | 2 | Screws M5 x 16 (Optional) |
17 | 1 | Styling rail (Optional) |
18 | 2 | Cap (Optional) |
Q.ty | Documentation | |
1 | Instruction Manual |
INSTALLATION
Wall drilling and bracket fixing
Wall marking:
- Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre of the area in which the hood will be installed.
- Draw a horizontal line at 650 mm above the hob for installation without the back panel, or at height H (height of the visible part of the panel) for installation with the back panel.
- Place bracket 7.2.1 on the wall as shown about 1-2 mm from the ceiling or upper limit aligning the centre (notch) with the vertical reference line.
- Mark the wall at the centres of the holes in the bracket.
- Place bracket 7.2.1 on the wall as shown at X mm below the first bracket (X = height of the upper chimney section supplied), aligning the centre (notch) with the vertical line.
- Mark the wall at the centres of the holes in the bracket.
- Mark a reference point on the horizontal reference line as indicated, 110 mm from the vertical reference line and 209 mm above the horizontal reference line.
- Repeat this operation on the other side.
- Drill ø 8 mm holes at all the centre points marked.
- Insert the wall plugs 11 in the holes.
- Fix the brackets using the 12a (4,2 x 44,4) screws supplied.
- Insert the two screws 12a (4,2 x 44,4) supplied in the hood body fixing holes, leaving a gap of 5-6 mm between the wall and the head of the screw.
REAR PANEL (OPTIONAL)
The Rear Panel must be fitted before fixing the hood body and, for both upper
and lower position fixing, must be fitted at the correct height prior to
installing the bases. As this operation is rather complex, it should be
carried out either by the kitchen installer or a qualified person who knows
the final dimensions of the units.
For the upper fixing position, proceed as follows:
- Rest the back panel on the base, inserting the lower plate between the upper surface and the wall, centring it on the vertical reference line.
- Mark the centres of the two holes in the upper plate.
- Drill ø 8 mm holes at all the centre points marked.
- Insert the wall plugs 11 in the holes.
- Fix the brackets using the 12a screws supplied.
- Fix the back panel (where present) using the 12a screws supplied.
|
---|---
Mounting the hood body
- Hook the hood body onto the screws 12a.
- Fully tighten the support screws 12a.
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney using
either a flexible or rigid pipe ø 150 or 125 mm, the choice of which is left
to the installer.
- To install a ø 125 mm air exhaust connection, insert the reducer flange 9 on the hood body air outlet and the adapting ring ø120-125 10a on the reducer flange.
- Fix the pipe in position using sufficient pipe clamps (not supplied).
- Remove any activated charcoal filters.
Exhausted mode Recommendations and suggestions
Connect the extractor to the exhaust flue through a pipe of minimum diameter
125 mm.
The route of the flue must be as short as possible.
Ideal ducting distance to discharge outlet is maximum of 3 meters straight
run, or 2 meters and one 90 degree bend preferably rigid duct.
Maximum ducting distance should be 3 meters, with one 90 degree bend.
For each additional 90 degree bend, the maximum distance is reduced by 1
meter.
If the ducting is not correct it will increase noise and reduce performance.
RECIRCULATION VERSION AIR OUTLET
- Push fit the air outlet fitting 15 onto the air outlet of the hood body.
- Ensure that the activated charcoal filters have been inserted.
ELECTRICAL CONNECTION
- Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm.
- Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan.
Fix the Utensil Rail
- Position the Utensil rail on the front part of the hood.
- Fix using the Utensil rail to the hood using the Screws 16.
- Insert the plugs 18.
Flue assembly
Upper exhaust flue
- Slightly widen the two sides of the upper flue and hook them behind the brackets 7.2.1, making sure that they are well seated.
- Secure the sides to the brackets using the 4 screws 12c (2,9 x 9,5) supplied.
Lower exhaust flue
- Slightly widen the two sides of the flue and hook them between the upper flue and the wall, making sure that they are well seated.
- Fix the lower part laterally to the hood body using the 2 screws 12c (2,9 x 9,5) supplied.
- On the recirculation version, fit the directional grids 8a – 8b in their housings making sure that the directional symbols are towards the top and front of the hood. Also make sure that they are correctly inserted in the connection extension pieces 14.1.
USE
L | Light | Switches the lighting system on and off |
---|---|---|
M | Motor | Switches the extractor motor on and off |
V | Speed | Sets the operating speed of the extractor: |
1. Low speed, used for a continuous and silent air change in the presence of
light cooking vapour.
2. Medium speed, suitable for most operating conditions given the optimum
treated air flow/noise level ratio.
3. Maximum speed, used for eliminating the highest cooking vapour emission,
including long periods.
CARE AND CLEANING
Grease filters
CLEANING METAL SELF- SUPPORTING GREASE FILTERS
- The filters must be cleaned every 2 months of operation, or more frequently for particularly heavy usage, and can be washed in a dishwasher.
- Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time.
- Wash the filters, taking care not to bend them. Allow them to dry before refitting.
- When refitting the filters, make sure that the handle is visible on the outside.
Grease filters
CLEANING METAL GREASE FILTERS
The filters are washable at least every 2 months of operation, or more
frequently for particularly heavy usage.
- Remove the filters one at a time by supporting them with one hand and turning the safety knobs (pull and turn).
- Wash the filters, taking care not to bend them. Allow them to dry before refitting.
- Refit them and fix them using the safety knobs provided (pull and turn).
Activated charcoal filter (Recirculation version)
REPLACING THE ACTIVATED CHARCOAL FILTER
- The filter is not washable and cannot be regenerated, and must be replaced approximately every 4 months of operation, or more frequently for particularly heavy usage.
- Remove the metal grease filters.
- Remove the saturated activated carbon filter by releasing the fixing hooks.
- Fit the new filter by hooking it into its seating.
- Refit the metal grease filters.
Lighting unit REPLACING OF THE LED UNIT
LED
- To remove the lighting unit a screwdriver can be used in order to slightly press the side part of the unit.
- Remove the unit, remove the electrical connector and replace the unit with a new one. (“To purchase contact technical support”)
Lamp | Power (W) | Socket | Voltage (V) | Dimension (mm) | ILCOS Code |
---|---|---|---|---|---|
4 | ### | 220-240 | 107 x 37 | DRBB/F-4-220-240-E14-35/100 | |
5 | GU10 | 230 | 52 x 50 | DRPAR-5/840-220/240-GU10-35/36 |
DRPAR-5/830-220/240-GU10-35/36
AGA RANGEMASTER GROUP PLC
Clarence Street, Royal Leamington Spa,
Warwickshire, CV31 2AD, England.
Tel: +44 (0) 1926 457400 Fax: +44 (0) 1926 45052
E-mail: consumers@rangemaster.co.uk
www.rangemaster.co.uk
Falcon is a business name of AGA RANGEMASTER GROUP PLC
991.0544.862_ver2 – 210217 – D00004657_01
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>