PerfectPrime AQ9600 Air Quality Particle Counter Instruction Manual

June 15, 2024
PerfectPrime

PerfectPrime AQ9600 Air Quality Particle Counter

Product Overview

  • Air quality detector has the function of measuring PM2.5, and PM10, counting dust particles, temperature, and humidity.
  • The product is provided with high measurement precision, stable performance, simple operation, and is convenient to carry.
  • It is suitable for indoor environments of family, offices, inside of cars natural environments, etc.

Considerations

  1. The electronic sensors and microprocessors used on the product belong to precision electronic device. The product must be kept away from water, fire, inflammable oil and gas or sites with strong electromagnetic interference to prevent influence on/damage to the device.
  2. Don’t block; or avoid strong air or hot air blowing to the air inlet for air sampling.
  3. Please use dry cloth to wipe the instrument case. Don’t use damp cloth or corrosive detergents.
  4. Don’t dismantle and remodel the product without authorization.

Product Description

Product structure and appearance description

  1. Case
  2. Temperature and humidity detection port
  3. Sampling air inlet
  4. LCD screen
  5. Keys
  6. Exhaust port
  7. Battery box
  8. Micro-USB

LCD description

  1. Hour/minute/second
  2. Year/month/day
  3. Battery level indication
  4. Counting unit
  5. Schematic diagram of concentration grade
  6. Display area of particle counting
  7. Humidity
  8. Temperature
  9. Measuring object
  10. Weight unit
  11. Display area of particle weight calculation

Key function description

  1. Power key[ ]: press to power on/off.
  2. Operating measurement key [RUN]
  3. At the main interface, press to start data sampling.
  4. During the sampling period, other keys are Disabled and inoperable. Only the power key will work.
  5. Enter key [ENTER]
  6. In the mode of historical record, confirm the page number of the selected pages.
  7. At the mode of functional parameters, press confirm to enter function change.
  8. At the mode of functional parameters, press confirm the saved items after the change.
  9. SHIFT key [SHIFT]
  10. At the mode of historical record, press-select the unit’s place, ten’s place, and hundred’s place of page number.
  11. At the mode of functional parameters, press-select the functional parameter items to be changed.
  12. Page up key[ ]
  13. At the mode of historical record, used to increase by 1 (+ 1) and page up by one page.
  14. At the mode of functional parameters and the change state: used to increase by 1 (+ 1 ); switching unit and select”yes” or”No”.
  15. Page down key[ ]
  16. At the main interface, press to enter the historical record-> the functional parameter.
  17. At the mode of historical record, used to decrease by 1 (-1) and page down by one page. At the mode of functional parameters and at the change state: used to decrease by1 (-1); switching unit and select”yes” or”No”.
  18. Back key [BACK]
  19. At the mode of historical record and functional parameters, press back to the main interface.
  20. At the mode of historical record, when to change a parameter, press exit from the change.

Remark

  • SOS sampling
  • Cannot switch languages

Function Setting Operation

  1. Historical Record

  2. Page number: Unit’s place/ten’s place/hundred’s place

  3. Check historical record: at the main interface, press [ ] key to enter historical record mode; press the [ENTER] key, and the current page is selected. At the moment, press[ ] key or [ ] key to go through the data. If you want to skip to a certain page directly, input the page number directly. Press the [SHIFT] key to select the unit’s place, ten’s place, and hundred’s place of the page number. Press the [ ] key to increase the value by 1 (+ 1) and press [ ] key to decrease the value by 1 (-1 ).

  4. Functional Parameters

  5. Particle unit: piece/L, ug/m3 Change the particle unit: at the main interface, press [ l key twice to enter the functional parameter mode, and press the [ENTER] key to enter the changing state. Press the [SHIFT] key to select piece/Lor ug/m3. At the moment, press the [ ] key or [Tl key to select your desired unit and press the [ENTER] key to confirm. Press the [BACK] key to return to the main interface.

  6. Time change
    At the main interface, press the [ l key twice to enter the functional parameter mode, and press the [ENTER] key to enter the change state. Press
    [SHIFT] three times to select”No” in the item of” Time Rev”. Press the [ ] key or [Tl key to select”Yes”. Press the [ENTER] key to enter the time change interface. Press the [SHIFT] key to select the items to be changed. Press the [ ] key to increase the value by 1 (+ 1) and press the [ l key to decrease the value by 1 (-1 ). Press [ENTER] to confirm. Press the [BACK] key to return to the main interface.

  7. Temperature unit: °Cl°F

  8. At the main interface, press the [ l key twice to enter the functional parameter mode, and press the [ENTER] key to enter the change state. Press the [SHIFT] key four times to select the items to be changed in “Temp Unit”. Press [ l key or [ l key to select “°C “or” °F ”.

  9. Press the [ENTER] key to confirm. Press the [BACK] key to return to the main interface.

  10. Restore factory-set value

  11. At the main interface, press [ ] key twice to enter the functional parameter mode, and press the [ENTER] key to enter the change state.

  12. Press the [SHIFT] key five times to select the items to be changed in “Rest”. Press[ ] key or [T] key to select”Yes”. Press the [ENTER] key to confirm.

  13. The screen displays “Rest Factory Data .. .”. After completion, press the [BACK] key to return to the main interface. (Users may also use the method to delete data records).

  14. language selection

    • From the main interface, press the [ l button twice to go to the function parameter mode. Press the [ENTER] button to go to the modification state. Press the [SHIFT] button six times to select
      “Language selection”.

    • Press the [ l button or the [ l button to select ‘Chinese’ or ‘English’. Press the [ENTER] button for confirmation, and press the [BACK] button to return to the main interface.

Measurement

  • The instrument should be placed in an open place first measure to avoid blocking the sensor. Press the power key to turn on, and press the [RUN] key on the main interface,the instrument will enter the sampling state. At the moment, do not operate the instrument first.
  • After completion of sampling, the measurement result will be displayed on the display screen finally. Users may enter the “Setting” interface to set the particle unit to realize the switching of measurement mode (cal mode 1/weighing mode).
    • Note: don’t carry out measurements at the time of charging to achieve a more accurate measurement result.

New Air Quality Standard

Battery Charging

Low battery may lead to failure of startup. Please charge it when the indicator shows up.

  1. Use an original adapter and cable for charging.
  2. Connecting the cable with the meter at the USB Interface.
  3. Charging at least 2 hours.
  4. Disconnecting the cable after finishing the charging

Product Specification

Principle of PM2.5 Sensors Optoelectronic type
Sampling method Pumping type
Light sources Laser diode
Grain size channels 0.3 2.5 l0um
Flowrate lL/min
Measurement range 0-1000ug/m3
Resolution ratio 1 ug
Test method Manual
Sampling time sos
Sampling method Pumping type
--- ---
Typical precision <20%
Concentration unit Piece/L I ug/m3
Temperature range 0 -so0c
Typical precision ±1°c
Humidity range 0 -99%RH
Typical precision ±2%RH
Work temperature -10-so0c
Working humidity 10 -90%RH
Stored data 1999 sets
Automatic power off 2 minutes(no key operation)
Power supply 18500 rechargeable lithium battery
Startup current 120mA
Working current About 230mA(voltage4.1 V)
Display method LCD value display
Screen size 2.8 inches
Screen resolution 320*240
Dimension 310g (battery included)
Size 245x 85x40mm

CUSTOMER SERVICE INQUIRIES

  • Your emails are important to us so we strive to reply to all inquiries and emails within 24 hours. In exceptional cases, we may require more time to respond.
  • Thank you for your understanding.
  • For more information about our products and services, please send us an email: at cs@uar1ac1urima.com.
  • For B2B or project-based applications, please send an email: to sa1es@uer1ec1urime.com.
  • FOR MORE INFORMATION ABOUT PERFECT PRIME PLEASE VISIT OUR ABOUT US PAGE AND FEEL FREE TO BROWSE.

Scan the QR Code for the Product Manual page (Multi-Language available for certain products)

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals