TENKER SM9126N TENS EMS Unit Muscle Stimulator User Manual
- June 8, 2024
- Tenker
Table of Contents
- TENKER SM9126N TENS EMS Unit Muscle Stimulator
- SUPPORTS
- INTRODUCTION
- SAFETY WARNINGS
- TRANSPORT AND STORAGE SYMBOLS
- CLEANING AND MAINTENANCE
- Product Specifications
- Features
- SET UP
- OPERATING THE PRODUCT
- MODE INTRODUCTION
- RECOMMEND USE POSITIONS
- RECOMMENDED PRACTICE
- TROUBLESHOOTING
- CONTACT INFORMATION
- FAQs
- Video
TENKER SM9126N TENS EMS Unit Muscle Stimulator
SUPPORTS
A Big Thank You
We’re thrilled that you have chosen to purchase the Electronic Massager
Machine. At TENKER, we’re committed to providing you with products that
enhance your daily life. We also aim to give our customers excellent support.
Should you have any questions or feedback about your new product, simply get
in touch with our customer support team at
1-855-558-8666, or by email at
support@tenker.co. Enjoy your new product!
INTRODUCTION
This Electronic Pulse Massager is a user-friendly product. This Electronic
Pulse Massager delivers electronic impulses to tired and sore muscles. These
impulses are generated by the device and delivered through electrodes to the
direct proximity of the target muscles. The impulses mimic the action
potential coming from the central nervous system to trigger the contraction of
the muscles. Some programs will improve resistance to fatigue and increase
endurance, while others can improve the force produced by the muscle.
This device is portable, compact, and stylish, as well as being controlled by
a microprocessor. It may be helpful in relieving minor aches and pains in
various parts of the body such as the waist, shoulders, Joints, hands, and
feet. The device is especially helpful in relieving stiff neck muscles and
sore muscles from over-exercising. Using it responsibly and properly will
provide you with a relaxing pulse massage. You will feel a real difference
this device can make in your life.
SAFETY WARNINGS
Danger
- Do not use this unit if you are using an implanted electronic medical device such as a pacemaker or other life-maintaining device.
- Do not use this unit if you are wearing electrode medical devices for monitoring health functions.
Warning
-
If you have any of the following conditions, please consult your physician before purchasing or using this device:
Acute conditions, malignant tumors, infectious diseases, pregnancy, implanted devices, heart disease, high fever, abnormal blood pressure, lack of skin sensation or numbness in the extremities, abnormal skin conditions or any condition requiring the active supervision of a physician. -
Please remove the battery from the device when it is not in use.
Notice
- Do not use this device while driving.
- Do not use this device while sleeping.
- Do not use this device in areas with high humidity such as a bathroom.
- Keep this device out of reach of children.
- Stop using this device and consult your physician at once if you feel pain, discomfort, dizziness, or nausea.
- Do not attempt to move the electrode heads while the device is in operation.
- Do not use the device near the heart, on the head, near the mouth, pudendum, or blemished areas of skin.
- Keep the device away from wet, hot places and out of direct sunlight.
- Store the device in a cool, dry place.
- Do dispose of batteries according to the local laws and regulations of your region.
- Medical electrical equipment needs special precautions regarding
- Portable and mobile RF communication equipment can affect medical electrical equipment.
TRANSPORT AND STORAGE SYMBOLS
CLEANING AND MAINTENANCE
Device
- Please use a lightly moistened cloth to clean the device and wipe it gently.
- Make sure the device is off when you clean it.
- Do not let water to get into the device.
Pads
- Make sure both pads not overlapping and make sure your skin is free from any dirt, oil or lotion.
- Applying a few drops water before and after usage will increase the longevity of the pads.
- Place pads on the pad holder or place plastic film on the sticky side of the pad to keep the gel moist.
Product Specifications
Included in this standard package:
- TENS devise x 1 pc
- Large pad x 2pcs
- Medium padx4pcs
- Small pad x 2pcs
- Electric wire x 3 pcs (when using 4 line cables, make sure to use at least 1 pc white(positive) +1 pc blue line (negative) at the time.)
- USB cable & AC adapter x 1 set
- Instruction manual x 1 pc
- Collection board for pad and wire x 1 pc
- Bag x 1 pc
Features
- Big size blue LCD screen
- 2 outputs with 16 modes
- 20 level intensity
- 20 minutes default timer, can be adjustable from 10-60 minutes Rechargeable lithium battery
- Battery indicator to know when need to recharge battery
- AC adapter 110-240v, USB Charger 5v
SET UP
Unpack the box of the product, take the product and accessories out, and connect the electrode pad to the device.
-
The device has two independent channels A&B . Make sure which channels (channel A or B or both) you want to use before you connect wires to the device.
-
Put pads on your skin before turning on the device. Use at least one pair of pads, one pad alone will not work.
-
Two output connector
-
USB port
-
LCD screen
-
Battery indicator
-
On/ off switch
-
Intensity adjustment
-
Mode selector
-
Time adjustment
-
Built-in Mode Selector
-
Pads- sticking board
-
Charger
-
USB cable
-
Massage pads
-
Pad wires
OPERATING THE PRODUCT
- Connect the pads to the wire by clipping them on, and then remove the protective film.
- Place the pads where the massage sensation is desired, and plug them into one of the ports on the device. For additional relief, repeat the procedure by putting another two pads on the desired area and plugging into the second port. Make sure both pads are on the skin and not overlapping and make sure your skin is free from any dirt, oil, or lotion.
- Turn the device on by sliding the on/off switch at the top of the unit to the ‘on’ position. The unit will be now activated.
- Press the “M” button to select a different main mode (there are 6 main modes to choose from, and each main mode contains different sub-modes). Press the center button to select a different sub-mode within the current main mode. Please remember that the strength setting will default to the lowest setting with each mode selection you make.
- Increase the intensity by pressing the + button; decrease the intensity by pressing the – button.
- Press the T button, 10,20,30,40,50,60mins timers could be selected. The default time is 20 minutes.
- Turns off the device.
- Remove the pads from your skin. Gently remove the pads from your skin and place them back on the provided pads holder or protective plastic film. Gently remove by pulling the corner of the pads. Do not pull the leads.
MODE INTRODUCTION
There are several modes to choose from; The “M” cycles through the 6 main
modes, while the silver middle button allows choices (from 2 to 4 varieties)
within that mode.
There are 16 small modes in total:
- Kneading
- Lateral palm kneading
- Flat palm kneading
- Crosscut fist kneading
- Vertical fist kneading
- Acupuncture
- Acupuncture
- Moxibustion
- Acupuncture kneading
- Cupping
- Rubbing reduction
- Cupping
- Fibrillation massage
- Tapping
- Lifting-pinching manipulation
- Vibrating manipulation
- Shiatsu-Deep
- Thai massage
- Shiatsu
- Auto-Combination
- Auto-Combination Massage Mode 1
- Auto-Combination Massage Mode 2
RECOMMEND USE POSITIONS
RECOMMENDED PRACTICE
- The duration suggested for each skin area is 20 min and 2 times per day. Consult with your physician for longer and more frequent uses.
- Start from the lowest intensity and gradually adjust the intensity to a comfortable level on a scale from 1 to 20.
- Good skin care is important for the comfortable use of the device. Be sure the treatment site is clean of dirt and body lotion.
- Keeping the electrode in the collector after use will extend its lifespan. The electrode is disposable and should be replaced when it loses adhesiveness. To purchase additional electrodes, please contact the seller.
TROUBLESHOOTING
If your device is not operating properly, please check below for common
problems and suggested solutions. If the recommended action does not solve the
problem, please contact the seller at
Official email: support@tenker.co
Tel No: 1-855-558-8666
CONTACT INFORMATION
Manufactured by:
Hong Qiangxing (Shenzhen) Electronics Limited Address:4F, Jingcheng Building,
Xicheng Industrial Area, Xixiang Street, Baoan District, Shenzhen, Guangdong,
China Wellkang, Ltd Suite B, 29 Harley Street London, United Kingdom WIG 9QR
OMGD INC
ADD: 245 East Main Street, Suite 115, Alhambra, CA 91801 Made in china
WEEE-Nr: DE83395812
FAQs
What is the difference between TENKER SM9126N and SM9126N?
The only difference between TENKER SM9126N and SM9126N is that TENKER SM9126N comes with a FREE carrying case.
What is the difference between TENKER SM9126N and SM9126?
The only difference between TENKER SM9126N and SM9126 is that TENKER SM9126N comes with a FREE carrying case.
What is the difference between TENKER SM9126N and SM8116?
The only difference between TENKER SM9126N and SM8116 is that TENKER SM9126N comes with a FREE carrying case.
What is the difference between TENKER SM8116 and SM8110?
The only difference between TENKER SM8116 and SM8110 is that TENKER SM8116 comes with a FREE carrying case.
What is the difference between TENKER EMS-081 and EMS-082?
The only difference between EMS-081 and EMS-082 is that EMS-081 has 4 modes, while EMS-082 has 8 modes.
What is the difference between EMS-081 and EMS-082?
The only difference between EMS-081 and EMS-082 is that EMS-081 has 4 modes, while EMS-082 has 8 modes.
How many times a day can you safely use a TENS unit?
TENS units can be used as frequently as you’d like without risk. typically once or twice day for 30 to 60 minutes. Up to four hours of relief are possible with TENS.
How often should you use EMS to build muscle?
The frequency and size of the EMS pulses should be high (between 50 and 100 Hz for young people and approximately 30 Hz for older people), and at least three sessions per week should be performed for at least five to six weeks.
Can you leave a TENS unit on all day?
Only 30 minutes at a time should be allotted for TENS stimulation. A 20-minute break is then suggested to give your skin a chance to rest after utilising TENS in one area of the skin for an extended period of time.
Can the TENS unit be damaged?
TENS is typically thought to be secure. But like any medical operation, it has hazards. For instance, the skin may burn or itch if the electrical current is too strong if the electrodes are put on the incorrect area of the body. The brain, heart, eyes, genitalia, and neck are among the “risk zones.”
What are the disadvantages of TENS therapy?
The majority of users of TENS units may do so without risk, and they typically don’t encounter any negative side effects. However, some individuals may find the buzzing, tingling, or prickling feeling brought on by a TENS unit to be uncomfortable. The adhesive pads may cause allergies in some persons.
How long should you wear a TENS unit?
A pain sufferer should utilize TENS for 20-minute intervals, according to user experience with TENS therapy. The user can apply the pads before going to bed and program the timer to turn off automatically on some TENS devices, such as The Pain Therapy System Pro.
Can TENS cause muscle weakness?
TENS can injure muscles severely if it is used on the human body for an extended period of time since it can lead to waste buildup and muscle exhaustion. Additionally, it has been claimed that TENS does not significantly reduce weariness following intense exercise3,4,5).
Video
Download PDF Link;TENKER SM9126N TENS EMS Unit Muscle Stimulator pdf
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>