THANK YOU
We appreciate the trust and confidence you have placed in Evertbilt through the purchase of this 2-in-1 utility pump. We strive to continually create quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs. Thank you for choOsing Everbilt!

Performance

EVERBILT-UTA02510-2-In-1-Utility-Pump-FIG-13

Safety Information

  • DANGER: Do not pump flammable or explosive liquids Such as oil, gasoline, kerosene, ethanol, etc. Do not use in the presence of flammable or explosive vapors. Using this pump with or near flammable liquids can cause an explosion or fire, resu lting in property damage, serious personal injury, and/or death
  • DANGER: ALWAYS disconnect the power to the pump before servicing.
  • DANGER: Do not touch the motor housing during operation. The motor is designed to operate at high temperatures. Do not disassemble the motor housing.
  • DANGER: Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface, or in water before disconnect the power.
  • WARNING: Release all pressure and drain all water from the system before servicing any component.
  • WARNING: Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing personal injury, and/or property damage.
  • WARNING: Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present a life threatening safety hazard if the insulation becomes damaged or the connection ends fall into water. The use of an extension cord to power this pump is not permitted.
  • WARNING: Wear safety goggles at all times when Working with pumps.
  • WARNING: This unit is designed only for use on 115 volts (single phase),60 Hz, and is equipped with an approved 3-conductor cord and 3-prong grounded plug. Do not remove the ground pin under any circumstances. The 3-prong plug must be directly inserted into a properly installed and grounded 3-prong, grounding-type receptacle. Do not use this pump with a 2-prong wall outlet. Replace the 2-prong outlet with a properly grounded 3-prong receptacle (a GFCI outlet) installed in accordance with the National Electrical Code and local cOdes and ordinances. AIl Wiring should be performed by a qualified electrician.
  • WARNING: Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not use damaged or worn cords.
  • WARNING: Failure to comply with theinstruction and designed operation of this unit may void the warranty. ATTEMPTING TO USE ADAMAGED PUMP can result in property damage, serious personal injury, and/or death.
  • WARNING: Ensure that the electrical circuit to the pump IS protected by a 10 Amp fuse or circuit breaker.
  • CAUTION: Do not lift the pump by the power cord.
  • CAUTION: Know the pump and its applications, limitations, and potential hazards.
  • CAUTION: Secure the pump to a solid base. This will aid in keeping the pump in a vertical orientation. This is critical in keeping the pump operating at maximum efficiency. It will also help prevent the pump from clogging resulting in premature failure.
  • CAUTION: Periodically inspect the pump and system components to ensure the pump suction screen is free of mud, sand, and debris. Disconnect the pump from the power supply before inspecting.
  • CAUTION: Follow all local electrical and safety codes, along with the National Electrical Code (NEC). In addition, all Occupational Safety and Health Administration (0SHA) guidelines must be followed.
  • CAUTION: Do not run the pump dry. Operating the pump without water will cause damage to the seals and the pump to fail, which voids the warranty.
  • IMPORTANT: The motor of this pump has a thermal protector that will trip if the motor becomes too hot. The protector wll reset itself once the motor cools down and an acceptable temperature has been reached. The pump may start unexpectedly if it is plugged in.
  • IMPORTANT: Ensure the electrical power source is adequate for the requirements of the pump.
  • IMPORTANT: Before using the pump, check the hose for holes or excess wear, which could cause leaks, and ensure the hose is not kinked or making sharp angles. A straight hose allows the pump to move the greatest amount of water quickly, and also check that all hose connections are tight to minimize leaks.
  • IMPORTANT: This pump is made of high-strength, corrosion-resistant materials. It will provide trouble-free service for a long time when properly installed, maintained, and used. However, inadequate electrical power to the pump, dirt, or debris may cause the pump to fail. Please carefully read the manual and follow the instructions regarding common pump problems and remedies.

Warranty

The manufacturer warrants the products to be free from defects in materials and workmanship fora period of two years from date of purchase. This warranty applies only to the original consumer purchaser and only to products used in normal use and service. If within two years this product is found upon examination by the manufacturer to be defective in materials or workmanship, the manufacturer’s only obligation, and your exclusive remedy, is the repair or replacement of the product at the manufacturer’s discretion, provided that the product has not been damaged through misuse, abuse, accident, modifications, alterations, neglect or mishandling. Your original receipt of purchase is required to determine warranty eligibility. The purchaser must pay all labor and shipping charges necessary to replace the product covered by this warranty. This Limited Warranty does not cover products which have been damaged as a result of an accident, misuse, abuse, negligence, alteration, improper installation or maintenance, or failure to operate in accordance with the instructions supplied with the products, or operational failures caused by corrosion, rust, or other foreign materials in the system. Requests for service under this warranty shall be made by returning the defective product to the manufacturer as soon as possible after the discovery of any alleged defect.

The manufacturer will subsequently take conrective action as promptly as reasonably possible. The manufacturer does not warrant and especially disclaims any warranty, whether express or implied, of fitness for a particular purpose, other than the warranty contained herein. This is the exclusive remedy and any liability for any and all indirect or consequential damages or expenses whatsoever is excluded. Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

Pre-Installation

APPLICATION

  • This pump can be used as a submersible utility pump. It is suitable for draining or removing water from the following: pits, sinks, window wells, basements, swimming pool covers, boats, low spot in yards, or other flooded areas.

  • This pump can be also used as a non-submersible transfer pump. t is suitable for draining or removing from the following: water heaters, boats, waterbeds, clogged sinks, aquariums, wash machines, utility sinks.
    WARNING: Risk of pump failure, property damage and bodily injury. Before using this pump to drain a hot water heater, be sure to read the manufacturer’s instructions. The water temperature in the water heater must be cooled down to 95°F or lower before draining with this pump.

  • This pump has not been tested or approved for use in swimming pools or in salt-water marine areas. This pump is not designed to function as a permanently installed sump pump. It is also not engineered to be run continuously as a “fountain” or “waterfall” pump.

  • Do not use where water recirculates.

  • Not designed for use as a swimming pool drainer.

MATERIALS REQUIRED (NOT INCLUDED)

  • NOTE: The hose is not shown to scale.

PACKAGE CONTENTS

EVERBILT-UTA02510-2-In-1-Utility-Pump-FIG-2EVERBILT-UTA02510-2-In-1-Utility-Pump-FIG-14

SPECIFICATIONS

EVERBILT-UTA02510-2-In-1-Utility-Pump-FIG-15

Submersible Utility Pump lInstallatioon

  • WARNING: Always disconnect power source before attempting to install, service, or maintain the pump. Never handle a pump with wet hands or when standing on wet or damp surface or in water. Fatal electrical shock could occur.
  • CAUTION: Always use the handle to lift the pump. Never use the power cord to lift the pump. To avoid skin burns, unplug the pump and allow time for it to cool after periods of extended use.

Connect the Garden Hose
Attach a 3/4 inch garden hose to the pump outlet. Use a garden hose that is no longer than 25 feet.

Plug in the Pump
Place the pump on a hard surface in water that is at least 11/2 inches deep. Do not place the pump directly on sand, dirt, or mud. Plug the pump into a properly grounded 115V GFCI outlet. Be sure the plus is secure and will not fall into the water. The pump should start immediately.

Operating the Pump

CAUTION: Do not run the pump dry. Operating the pump Without water will cause damage to the seals and will cause the pump to fail, which voids the pump’s warranty.

Allow the pump to run and monitor its progress. Unplug the pump when it has removed water down to approximately 1/2 inch.

Airlock

This pump is a centrifugal utility pump, designed to efficiently remove water. However, it cannot move air. If air is trapped inside the pump (a condition called “airlock”), the pump cannot pump water out even though the pump is completely submerged. This pump has an anti- airlock hole. Air flows out through the anti-airlock hole, eliminating the airlock so that the pump can operate properly. If debris blocks the anti-airlock hole, unplug the pump, clean out the anti-airlock hole, and restart the pump. Alternately, drain the water out of the garden hose, keep the end of the hose out of the water, and plug in the power cord, restarting the pump.

CAUTION: This hole is for anti-airlock purposes only. Leakage of air or water is normal and necessary.

DO NOT REMOVE OR PLUG THIS HOLE!

Non-Submersible Transfer Pump Installation

WARNING: Always disconnect power source before attempting to install, service, or maintain the pump. Never handle a pump with wet hands or when standing on wet or damp surface or in water. Fatal electrical shock could occur.

CAUTION: Always use the handle to lift the pump. Never use the power cord to lift the pump. To avoid skin burns, unplug the pump and allow time for it to cool after periods of extended use.

The following picture shows a typical installation. The suction lift of this unit can get up to 8 feet. Be sure to use the special designed check valve build-in suction strainer included in the package.EVERBILT-UTA02510-2-In-1
-Utility-Pump-FIG-7

Connect the Suction Strainer and Suction Hose

  • Attach the Suction hose included with your μump to the Suctioo Strainer. Make sure the gaskets in the Suctioo hose are airtight or the t11e pump will not pump water.
  • Lay the tile pump on Its side and the bottom cover. Attach the tl1e other end or Ille Suction hose to the tl1e pump Inlet.

Attach the Garden Hose

  • Attach a 3/4 inch Qillden hose to the pump outlet. Use a garden hose that is no longer than 25 feet. Keep both tile Suction hose and Garden hose as s1Jaigllt as possible. The end of the tile Garden lose should be OUT of tl1e water.

Prime the Pump

Unscrew the priming plug. Fill water until the tile suction hose is completely filled and overflowing witl1 water. lighten pro ming plug.

Operating the Pump

NOTE:If the pump is not pumping water in 30 seconds, unplug the pump. Check the connections on the two ends of the Suction hose to make sure there are no air leaks. Repeat the priming instructions.

  • Place the Suction Strainer on a level surface IN the water. The garden hose and pump should be OUT of the water.
  • Plug the pump into a properly grounded 115V GFCI outlet. The pump should start within 30 seconds. Monitor the pump’s progress and unplug the pump before it runs dry.

Care And Cleaning

CAUTION: Always use the handle to lift the pump. Never use the power cord to lift the pump. To avoid skin burns, unplug the pump and allow time for it to cool after periods of extended use.

Do

  • When the power is disconnected, inspect the pump suction screen and remove all debris, then plug the pump back into the grounded (GFC) outlet.

Do Not

  • Do not disassemble the motor housing. This motor has NO repairable internal parts, and disassembly may cause leakage or dangerous electrical wiring issues.
  • Do not lift up the pump by the power cord.

To clean a pump clogged with debris
Unplug the pump from electrical power. Remove debris from the screen .EVERBILT-UTA02510-2-In-1-Utility-Pump-FIG-12

Troubleshooting

Submersible Utility & Non-submersible Transfer. Pump does not start or run .EVERBILT-UTA02510-2-In-1-Utility-Pump-FIG-16

Submersible Utility

Problem 1: Pump does not pump waterEVERBILT-UTA02510-2-In-1-Utility-Pump-
FIG-17

Non-Submersible Transfer

Problem 1: Pump does not prime.EVERBILT-UTA02510-2-In-1-Utility-Pump-
FIG-18

Problem 2: Flow rate is too low.EVERBILT-UTA02510-2-In-1-Utility-Pump-
FIG-19 Questions, problems, missing parts? Before returning to the store call Everbilt Customer Service8 a.m.-6 p.m., EST, Monday-Friday 1-844-241-5521 www.HOMEDEPOT.CA