intelbras IVP 3011 Teto Passive Infrared Sensor User Manual

June 13, 2024
intelbras

intelbras IVP 3011 Teto Passive Infrared Sensor User Manual

IVP 3011 Teto (Ceiling)

Congratulations, you just have purchased a product with Intelbras quality and safety.
IVP 3011 Teto sensor has a 360° view angle and its detection is done by passive infrared rays, reducing the risk of false shots.

Caution and safety

  • LGPD – General Law for the Protection of Personal Data: Intelbras does not access, transfer, capture, or perform any other type of treatment of personal data from this product.
  • Follow all instructions of the manual for product mounting and installation.
  • This movement sensor is to be used in indoor environments.
  • Do not touch on surface of the infrared sensor (PIR). If necessary, use a soft cloth with alcohol to clean.
  • The sensor must be installed where a possible intruder could be easily detected, that is, where a person does transversal movements in relation to the sensor detection beams when entering into the environment. The suggested installation height is 4 m.
  • Do not put objects in front of the sensor that may block scanning.
  • Avoid installing the sensor near to the following interference sources: reflexive surface, areas subject to sudden temperature changes (such as air conditioners and heaters, fans, refrigerators and ovens).
  • Avoid installing in places where sunlight goes directly onto the sensor.
  • Install the sensor in a stable and shake-free place.
  • For your safety, perform test of product and systems at least once a week. It is necessary due to changes in environmental conditions, electronic failures or power outage and flaws. Take all the required precautions to keep your property safe and protected.

Top view scan

Detection range (side view)

FIG 2 Detection range.JPG

Terminal block

  • Tamper: Anti-tamper key
  • (-) GND: negative source
  • (+) 12 V: Positive source
  • Alarm: sensor output

FIG 3 Terminal block.jpg

FIG 4 Terminal block.jpg

1. Technical specifications

FIG 5 Technical specifications.JPG

Note: the infrared detection range can be influenced by the environment.

2. Features

  • Ceiling installation.
  • Digital signal processing (DSP).
  • Automatic temperature compensation.
  • Anti-tamper protection (tamper key).
  • Adjustable infrared sensitiveness (PIR).
  • Optional NC and NO relay output.

3. Product

FIG 6 Product.jpg

  1. Front
  2. Lens
  3. Base
  4. Bolt fixation holes
  5. Cable passage
  6. Jumper P.COUNT (pulse counter)
  7. Jumper Relay
  8. PIR sensor
  9. Jumper LED
  10. LED Indicator
  11. Terminal Block (connectors)
  12. Tamper key (anti-violation)

4. Installation

  • Execute the installation in an area free of obstacles that may hinder the visual field of the sensor.
  • The PIR (P-COUNT) sensitivity adjustment must be done according to each environment.

To attach the sensor in the ceiling, follow the procedure:

  1. Open the front cover pulling it upward (figures 1A and 1B);
  2. Pass the cable through the cable passage orifice in the back cover (Fig. 2);
  3. Pass the cable through the orifice and connect it to the terminal block (item 1.3. Terminal block);
  4. Attach the sensor in the ceiling, passing the screw through the holes in the back cover (Fig. 3).

Note: drilling screw M3 × 25.

FIG 7 Installation.JPG

FIG 8 Installation.JPG

5. Operation

LED jumper is used for LED indication without interfering with the detector. Jumper in ON position (pin 1 & 2) light on. Jumper in OFF position (pin 2 & 3) light off. Factory standard: LED on.

The P.COUNT jumper controls the pulse count for alarm activation. With the jumper in the 1P position, the sensor provides maximum sensitivity (one pulse, pins 1 & 2) With the jumper in the 2P position, the sensor provides intermediary sensitiveness (two pulses, pins 2 & 3), and in this position, the sensor provides proper detection for environments with high incidence of EMI and RFI interferences. Factory standard: 2P.

Note: if the P.Count jumper is open, the sensor sensitivity will be 2P.
The RELAY jumper controls the relay contact status. With jumper in the NC position, the contact is normally closed. With jumper in the NO position, the contact is normally open. Factory standard: NC.

FIG 10 Operation.jpg

FIG 11 Operation.jpg

6. Test

When energized, the LED lights on, indicating that the self-test has been activated by the sensor.
It performs the walk-through test, with transversal movements to sensor detection, by observing the LED indication.

Note: while a movement could be detected, the LED remains on and will indicate open or closed.
Walk through the area where you want to protect to check if it is within the area covered by the sensor. The sensor sensitivity and its installation position will define the coverage area.

FIG 12 Test.JPG

Term of Warranty

It is expressed that this contractual warranty is granted according to the following conditions:

Customer name:
Customer’s signature:
Tax Invoice No.
Date of Purchase:
Model: Serial No.:
Retailer

  1. All parts, pieces and components of this product are warranted against any manufacturing defects, which may arise within a period of 1 (one) year – being 90 (ninety) days of legal warranty and 9 (nine) months subject to contractual warranty – from the date when the Customer purchased the product, according to the product purchase tax invoice, which is an integral part of this Term throughout the Brazilian territory. This contractual warranty expressly includes the product exchanges in case of manufacturing defect. If no manufacturing defect is confirmed, but there is a failure due to improper use, the Customer shall bear any of these incurred expenses.
  2. The product must be installed according to the Product Manual and/or Installation Guide. If your product requires to be installed and configured by a skilled technician, your should seek for a reliable and skilled professional, but the costs of such services are not included in the product price.
  3. Once the defect is confirmed, the Customer shall contact immediately the nearest Authorized Service listed in the report provided by the manufacturer, they are the only professionals authorized to check and remedy the defect within the warranty term provided herein. It it is not observed, the warranty is void, characterized as product infringement.
  4. Eventually, if the Customer requests service at home, he/she may contact the nearest Authorized Service to ask for fee quotation of a technical visit. If it is necessary to withdraw the product to be repaired, the incurred expenses such as transportation and insurance costs, including taking and return after repaired, are under responsibility of the customer.
  5. The warranty will be entirely voided if any of the following cases occur: a) if the defect is not due to manufacturing, but caused by the Customer or by third parties foreign to the manufacturer; b) if the product damages are caused by accident, disasters, agents of nature (lightning, flooding, landslide, etc.), humidity, network voltage, over-voltage caused by accident or excessive network voltage fluctuations), installation/use in disagreement with the user’s manual or due to natural wear of parts, pieces and components; c) if the product had suffered any effects of chemical, electromagnetic, electric or animal (insects, etc.) nature; d) if the product serial number was altered or erased; and e) if the appliance is flawed.
  6. This warranty does not cover data loss, therefore, in case of a product, it is advisable to the Customer to regularly make secure backup of the product data.
  7. Intelbras is not liable for the installation of this product, as well as eventual attempts of fraud and/or sabotage in their products. Keep software and applications up to date, and if necessary, the required network protections against intrusions (hackers). The equipment is warranted against defects under normal conditions of use, and it is important to bear in mind that, because it is an electronic equipment, it is not protected from attempts of frauds or misleading actions that may interfere in its correct operation,
  8. After its useful life, the product must be delivered to an Intelbras authorized support service or perform environmentally proper final disposal in order to avoid environmental or health impacts. If you prefer, useless cells and batteries as well as other Intelbras branded electronic appliances may be disposed at any Green Eletron collection points (electro-electronic residues management company to which we are associated). If you have any questions about the reverse logistics process, contact us by phone (48) 2106 0006 or 0800 704 2767 (from Monday to Friday at 8 AM to 8 PM, and on Saturday at 8 AM to 6 PM) or via e-mail suporte@intelbras.com.br.

Also under these supplementary Term of Warranty, Intelbras S/A reserves the right to alter general, technical or aesthetics features without prior notice.
All images in this manual are for illustrative purposes only.

Customer Support: (48) 2106 0006
Forum: forum.intelbras.com.br
Support via chat: chat.intelbras.com.br
Support via e-mail: suporte@intelbras.com.br
Customer Service: 0800 7042767
Where to buy? Who installs it? 0800 7245115
Imported to Brazil by: Intelbras S/A – Indústria de Telecomunicação Eletrônica Brasileira
Rodovia SC 281, km 4,5 – Sertão do Maruim – São José/SC – 88122-001
CNPJ 82.901.000/0014-41 – www.intelbras.com.br

Made in China

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals