GE current LEDL136 LED Double Ended Type B T8 Tubes Installation Guide
- June 8, 2024
- GE current
Table of Contents
GE current LEDL136 LED Double Ended Type B T8 Tubes
The Type B LED T8 Tubes listed above are to be used with G13 (medium bi-pin)
lamp holders that are either internally or externally shunted
R is a number representing CRI; XX are numbers representing CCT, @ may be any
character(s) representing additional lamp features
BEFORE YOU BEGIN
Read these instructions completely and carefully
- To install the Type B LED T8, please read the entire installation guide carefully.
- To protect against future misapplication, Current recommends installing an in-line fuse: Type 2AG, rated at 1 amp, 500 volts, Littlefuse part number 0477001.MXP or equivalent
Ensure that package includes installation guide, warning label to be attached to luminaire, LED T8 tube. Minimum fi xture volume for 4 lamps is 48 inches long x 24 inches wide x 4 inches deep (4’). Minimum socket spacing is 4.4 inches apart. Product is not intended to be used with dimmers or emergency lighting. This LED T8 tube is not suitable for direct replacement of linear fl uorescent lamps in luminaires where the lamps are connected to a ballast. The technical and safety requirements of the converted luminaire are the sole responsibility of the party doing the conversion and shall comply with the local applicable safety and regulatory laws and standards. The provided Caution label should be placed onto the converted luminaire to indicate that the luminaire has been modified and can no longer be used with conventional fluorescent lamps.
RISK OF FIRE OR ELECTRIC SHOCK
LED Retrofi t Kit installation requires knowledge of luminaire electrical systems. If not qualifi ed, do not attempt installation. Contact a qualifi ed electrician. Install this kit only in luminaries that have the construction features and dimensions shown in the drawings and where the input rating of the retrofi t kit does not exceed the input rating of the luminaire. To prevent wiring damage or abrasion, do not expose wiring to the edges of sheet metal or other sharp objects. Installers should not disconnect existing wires from lampholder terminals to make new connections at lampholder terminals. Instead, installers should cut existing lampholder leads away from the lampholder and make new electrical connections to the lampholder lead wires by employing applicable connectors (or replace with new shunted lamp holders). THIS RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION. THE PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH THE APPLICABLE AND APPROPRIATE ELECTRICAL CODES. THE INSTALLATION GUIDE DOES NOT SUPERSEDE LOCAL OR NATIONAL REGULATIONS FOR ELECTRICAL INSTALLATIONS. Installers should examine all parts that are not intended to be replaced by the retrofi t kit for damage and replace any damaged parts prior to installation of the retrofit kit. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. This lamp operates directly from 120V-347V mains. Do not use Ballast or any starting aid. Do not connect to a voltage higher than 347 volts. To reduce risk of misapplication, Current recommends installing a fuse in series with the Phase or Hot lead and the SHUNTED (Instant Start style) lamp holder(s) per the wiring diagrams below. Only one fuse kit is needed for up to 4 tubes in the same fixture. Ensure the lamp holders are SHUNTED for Double Ended T8 applications.
Installation Instructions
-
Ensure power is off to luminaire by disconnecting the supply voltage.
-
Remove all fl uorescent lamps and ballast/ wiring area cover. Cut the ballast lead wires about 6 inches away from each lamp holder.
-
If two wires come from an existing lamp holder (rapid start type), these two wires should be wired or shunted together.
-
Connect the recommended fuse and fuseholder (not supplied) to the black (hot) wire from the mains.
-
Connect together all of the lampholder leads on one side and connect to the other side of the recommended fuse with suitable wire.
-
Connect together all of the lamp holder leads on the other side of the fi xture and connect to the white or neutralwire from the mains.
-
Replace the ballast / wiring area cover, ensuring no wires are pinched between the cover and the fixture
-
Install the retrofit kit
Caution label in an easy to see location to ensure the user understands the system now uses LED Type B double ended tubes, and the use of fl uorescent lamps may result in damage or injury. -
Install Type B double ended tubes
-
Re-apply power to fi xture and ensure proper operation.
This lamp is designed for general lighting service. This lamp may not be
suitable for use in all applications where a conventional fl uorescent lamp
has been used.
This Class A device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. Any changes or
modifi cations not expressly approved by the manufacturer could void the
user’s authority to operate the equipment. This device complies with CAN ICES-
005A.
NOTE : This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to
provide reasonable protection against harmful interference when the equipment
is operated in a commercial environment. This equipment generates, uses, and
can radiate
radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the
interference at his own expense
www.gecurrent.com
© 2021 Current Lighting Solutions, LLC. All rights reserved. GE and the GE
monogram are trademarks of the General Electric Company and are used under
license. Information provided is subject to change without notice. All values
are design or typical values when measured under laboratory conditions.