PREDRICK RAMOND FR41503 LED Convertible Semi Flush Mount Instruction Manual

June 17, 2024
PREDRICK RAMOND

PREDRICK RAMOND lOGO A Division of Hinkley Lighting, Inc.
33000 PIN OAK PARKWAY
AVON LAKE, OHIO 44012
toll free 800.446.5539
phone 440.653.5500PREDRICK RAMOND FR41503 LED Convertible Semi Flush
Mount

Assembly Instructions

Item No. FR41503

  1. Find a clear area in which you can work.
  2. Unpack fixture and glass from carton.
  3. Carefully review instructions prior to assembly.
    1.To begin, it will be necessary to attached the top loop (1) onto main body frame (a) by threading in to threaded tube (2) and tighten.
    2.Fixture can now be installed. This is accomplished by following instruction before sheet (I S-19) provided. Please read all the instruction starting installation.

Alabaster installation:

  1. To begin installation, first, unwrap the alabaster disc from their packing
  2. After fixture is installed, the alabaster disc can be attached. by taking the alabaster disc and hook it through the slot holes at cage frame.
  3. Now, do the same process until the frame is completely dressed up. Make sure when attaching all alabaster disc that you accidentally do not skip slot holes on the frame.

PREDRICK RAMOND FR41503 LED Convertible Semi Flush Mount -
Fig

FRIS 19 HANGING INSTRUCTIONS

Safety Warning: Read wiring and grounding instructions [FRIS 18] and any additional directions. Turn power supply off during installation. If new wiring is required, consult a qualified electrician or local authorities for code requirements.
STEP 1

  1. Shut off electrical current before stating. If the fixture you are replacing is turned on and off by a wall switch, simply turn the switch off, If not, Remove the appropriate fuse (or open the circuit breakers) until the fixture is dead.
    • DO NOT: resorted current – either by fuse, breaker or switch – until the new fixture is completely wired and in place.

STEP 2

  1. Fasten mounting strap (1 ) to outlet box (a) with the original outlet box screws (2 ) – see Drawing 1 .
  2. Thread nipple (3 ) into mounting strap (1 ).
  3. Thread loop (4 ) onto end of nipple (3 ).
  4. Slip canopy (3 ) over loop (4 ) and adjust height of loop so half of thread area is exposed.

STEP 3 [DRAWING 2]
Half of thread area of loop (4 ) is to be exposed.
This will allow collar (5 ) to be threaded on later.

  1. Taking the chain, determine the length you require to hang the fixture.
  2. Attach one end of the chain to the top loop of the fixture – see Drawing 2 .
  3. Now slip loop collar (5 ) and canopy (b) onto chain.
  4.  Attach other end of chain to loop (4 ). Get assistance for this step since fixture may be heavy and difficult to hold while attaching the chain.

STEP 4

  1. Unwrap supply wire and ground wire and weave them up through the chain.
  2. Slip supply wire and ground wire through center of loop (4 ).
  3. Connect ground wire to mounting strap (1 ) using green ground screw (6 ).
  4. Make electrical connections from supply wire to fixture lead wires. Refer to instruction sheet [FRIS 18 ] and follow all instructions to make all necessary wiring connections.
  5. Slip canopy up firmly against the ceiling and secure by turning the threaded collar (5 ) on loop (4 ) until tight.

FRIS18
WIRING AND GROUNDING INSTRUCTIONS
Safety Warning:
Read wiring and grounding instructions [FRIS 18] and any additional directions. Turn power supply off during installation. If new wiring is required, consult a qualified electrician or local authorities for code requirements.
STEP 1 WIRING INSTRUCTIONS
Indoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – See Drawing 1 or 2.
  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D)
  3. Please refer to the grounding instructions below to complete all electrical connections.

Outdoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – See Drawing 1 or 2.

  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D)

  3. Cover open end of connectors with silicone sealant to form a watertight seal.
    • If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.

  4. Please refer to the grounding instructions below to complete all electrical connections.

PREDRICK RAMOND FR41503 LED Convertible Semi Flush Mount - DRAWING
1

STEP 2 GROUNDING INSTRUCTIONS

Montaje Embutido Accesorios
For positive grounding in a 3 -wire electrical system, fasten the fixture ground wire ( E) (typically copper or green plastic coated) to the fixture mounting strap (1) with the ground screw (2) – See Drawing 1 .
Note: On straps for screw supported fixtures, first install the two mounting screws in strap.
Any remaining tapped hole may be used for the ground screw.
Cadena Hung Accesorios
Loop fixture ground wire ( E) (typically copper or green plastic coated) under the head of the ground screw (2) on fixture mounting strap (1) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors – See Drawing 2 .
Accesorios Posterior Monte
Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector inside post.
Cover open end of connector with silicone sealant to form a watertight seal – See Drawing 3.

PREDRICK RAMOND lOGO

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals