SmartGen HRM3300 Remote Control Module User Manual

June 8, 2024
SmartGen

HRM3300 Remote Control Module
User ManualSmartGen HRM3300 Remote Control Module ZHENGZHOU SMARTGEN TECHNOLOGY CO.,LTD

HRM3300 Remote Control Module

SmartgGen — make your generator smart
SmartGen Technology Co., Ltd.
No. 28 Jinsuo Road
Zhengzhou City
P. R. China
Tel: +86-371-67988888
+86-371-67981888
+86-371-67991553
+86-371-67992951
+86-371-67981000 (overseas)
Fax: 0086-371-67992952
Web: http://www.smartgen.com.cn/
http://www.smartgen.cn/
Email: sales@smartgen.cn

All rights reserved. No part of this publication may be reproduced in any material form (including photocopying or storing in any medium by electronic means or other)  without the written permission of the copyright holder.
Smartgen Technology reserves the right to change the contents of this document without prior notice.
If the colors of actual products are different from the manual, please take the actual product as the standard.

Software Version

Date Version Content
2013-12-05 1.0 Original release.
2015-03-25 1. Modify case dimension.

This manual is suitable for HRM3300 remote control module only.
Clarification of notation used within this publication.

SIGN INSTRUCTION
NOTE Highlights an essential element of a procedure to ensure correctness.
CAUTION! Indicates a procedure or practice, which, if not strictly observed,

could result in damage or  destruction of equipment.
****WARNING!| Indicates a procedure or practice, which could result in injury to personnel or loss of life if not followed correctly.

OVERVIEW AND FEATURES

HRM3300 remote control module is a remote control module for HMC9000 controller. With the help of CANBUS it can carry out remote start/stop of the marine genset, data measurement, alarm display and other functions.
HRM3300 is designed for single generator remote control systems. The module has monitor mode, in which it only monitors, but does not control the genset. Up to 16  HRM3300 modules can be connected to one HMC9000 controller.
The module contains 32-bit ARM microprocessor; it is fitted with a large 480*272 resolution TFT-LCD monitor, selectable English/Chinese interface.
The home page of the monitor is instrument display. The brightness of the LCD monitor and LED light indicators can be adjusted, which enables operation in different  conditions. The module is designed for panel mounting, it has simple structure, simple connections and can be widely used in various situations.

SPECIFICATION

Items Content
Operating Voltage DC18.0V to 35.0V, continuous power supply.
CANBUS Baud rate 125kbps
Max. transmission distance 500m
LCD/LED Brightness 11 Stage adjustable
Total consumption 52W
Overall dimension 266mm x 182mm x 45mm
Panel cutout 214mm x 160mm
Shell material Self extinguishing ABS+PC
Button material Silicon rubber
Working Conditions Temperature: (-25-+70)°C Humidity: (20-93)%RH
Storage Condition Temperature: (-25-+70)°C
Protection Level IP55 Gasket
Weight 0.75kg

DISPLAY

3.1 PUSHBUTTONS

| Stop| Stop running generator in remote mode; During stopping  process, press this button again to stop generator immediately.
---|---|---
| Start| Start genset in remote mode.
| Sound Alarm Acknowledge| In case of sound alarm pressing this button will mute the panel buzzer.
| Light
Alarm
Acknowledge| In case of alarm pressing this button will return flash indicator to its illuminating condition.
| Lamp Test| Pressing this button will illuminate all the LED indicators on the  panel and highlight the LCD monitor.
| Brightness+| Pressing and holding this button can increase brightness of LCD monitor and LED indicators.
| Brightness-| Pressing and holding this button can decrease brightness of LCD monitor and LED indicators.
| Up/Increase| Scroll the screen up.
| Down/Decrease| Scroll the screen down.
| Left| Scroll the pages left.
| Right| Scrolls the pages right.
| Homepage| Press this button to return to the home page; In settings menu press this button to save changes.
| Settings| Press this button to enter  into settings screen;
In settings menu press this button to return to previous menu.

3.2 LCD DISPLAY
Data displayed on the LCD is obtained from HMC9000 via CANBUS port. Press to switchover between the pages of the monitor. Press to return to the
home page and to enter into parameter configuration pages.

3.2.1 MAIN DISPLAY (HOME PAGE)
The main screen displays engine speed, coolant temperature, oil pressure, two batteries voltage and engine status. The main screen looks as follows:

3.2.2 DATA DISPLAY
The main screen is divided into two separate viewing areas: left and right.
Left area has only one page and shows diesel engine operation status and battery status; press to view the right area. Right area is divided into pages: engine page, alarm  page, expansion module data page and event log page etc.

  1. Engine page
    Displays engine speed, sensors 1-8 values, main battery voltage, standby battery voltage, charger voltage, GOV output ratio, total run time and total start times.
    For J1939 engines, an additional ECU page will be displayed. ECU data includes coolant pressure, coolant level, fuel temperature, fuel pressure, inlet temperature,  exhaust temperature, turbo pressure, fuel consumption, total fuel consumption etc (Different engine with different parameters).

  2. Alarm page:
    It displays all kinds of warning alarms and shutdown alarms which detected by controller.

  3. Other parameters page
    HMC9000 main controller’s date and time, inputs/outputs status.

OPERATION

Press and input the password to enter into parameter configuration menu.
Configurable parameters include displayed language, operation mode and password.
The module has two operation modes:

  1. Monitor mode, in which and buttons have no effect.
  2. Control mode, in which the engine can be stopped and started by press and pushbuttons; this mode activates only if HMC9000 is in remote mode.

4.1 REMOTE START/STOP PROCEDURE
Remote mode is selected by pressing the button; a LED besides the button will illuminate to confirm the operation;

  1. Remote start
    Press button to start the gen-set, then preheat delay, safety on delay, start idle delay and warming up delay will be displayed on the screen in turn (according to the  engine settings);

  2. Remote stop
    Press button, then the screen will display cooling down delay, stop idle delay, ETS delay and fail to stop delay in turn (according to the engine settings); Note: If an  alarm condition occurs during starting or stopping procedure, alarm information will be synchronously displayed on HRM3300 LCD.

4.2 ACKNOWLEDGE OPERATION

In case of alarm pressing and buttons will mute the panel buzzer and return flash indicator to its illuminating condition. In case of new alarm situation, sound  alarm will be initiated again and the light indicator will start flashing and the user will have to press the acknowledge buttons again to clear them.

BACK PANEL

HRM3300 controller back panel is shown below:

Terminal connections description:

Terminal Function Cable Size Description
1 B- 1.0mm2 Power supply negative input.
2 B+ 1.0mm2 Power supply positive input.
3 NC Not connected
4 SCR (REMOTE) 0.5mm2 A CANBUS port which communicate

with main control. Impedance-1200
shielded wire with its one end connected to ground is recommended. There is 1200 terminal resistance
inside already; if needed, make
5| CAN(H) (REMOTE)
6| CAN(L) (REMOTE)
7| RE (120Ω
resistance)| | terminal 6, 7 short circuits.
| USB| | Factory use

APPLICATION DIAGRAM

HRM3300 Application Diagram

INATALLATION

Controller is panel built-in design; it is fixed by clips when installed. The controller’s overall dimensions and cutout dimensions for panel, please refers to as following, SmartGen HRM3300 Remote Control Module - Figure
4

HRM3300 Remote Control
Module 2015-03-25
Version1.1

Documents / Resources

| SmartGen HRM3300 Remote Control Module [pdf] User Manual
HRM3300, Remote Control Module, HRM3300 Remote Control Module, Module, HRM3300 Module
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals