SmartGen HRM3300 Remote Control Module User Manual
- June 8, 2024
- SmartGen
Table of Contents
HRM3300 Remote Control Module
User Manual
ZHENGZHOU SMARTGEN TECHNOLOGY CO.,LTD
HRM3300 Remote Control Module
SmartgGen — make your generator smart
SmartGen Technology Co., Ltd.
No. 28 Jinsuo Road
Zhengzhou City
P. R. China
Tel: +86-371-67988888
+86-371-67981888
+86-371-67991553
+86-371-67992951
+86-371-67981000 (overseas)
Fax: 0086-371-67992952
Web: http://www.smartgen.com.cn/
http://www.smartgen.cn/
Email: sales@smartgen.cn
All rights reserved. No part of this publication may be reproduced in any
material form (including photocopying or storing in any medium by electronic
means or other) without the written permission of the copyright holder.
Smartgen Technology reserves the right to change the contents of this document
without prior notice.
If the colors of actual products are different from the manual, please take
the actual product as the standard.
Software Version
Date | Version | Content |
---|---|---|
2013-12-05 | 1.0 | Original release. |
2015-03-25 | 1. | Modify case dimension. |
This manual is suitable for HRM3300 remote control module only.
Clarification of notation used within this publication.
SIGN | INSTRUCTION |
---|---|
NOTE | Highlights an essential element of a procedure to ensure correctness. |
CAUTION! | Indicates a procedure or practice, which, if not strictly observed, |
could result in damage or destruction of equipment.
****WARNING!| Indicates a procedure or practice, which could result in
injury to personnel or loss of life if not followed correctly.
OVERVIEW AND FEATURES
HRM3300 remote control module is a remote control module for HMC9000
controller. With the help of CANBUS it can carry out remote start/stop of the
marine genset, data measurement, alarm display and other functions.
HRM3300 is designed for single generator remote control systems. The module
has monitor mode, in which it only monitors, but does not control the genset.
Up to 16 HRM3300 modules can be connected to one HMC9000 controller.
The module contains 32-bit ARM microprocessor; it is fitted with a large
480*272 resolution TFT-LCD monitor, selectable English/Chinese interface.
The home page of the monitor is instrument display. The brightness of the LCD
monitor and LED light indicators can be adjusted, which enables operation in
different conditions. The module is designed for panel mounting, it has
simple structure, simple connections and can be widely used in various
situations.
SPECIFICATION
Items | Content |
---|---|
Operating Voltage | DC18.0V to 35.0V, continuous power supply. |
CANBUS Baud rate | 125kbps |
Max. transmission distance | 500m |
LCD/LED Brightness | 11 Stage adjustable |
Total consumption | 52W |
Overall dimension | 266mm x 182mm x 45mm |
Panel cutout | 214mm x 160mm |
Shell material | Self extinguishing ABS+PC |
Button material | Silicon rubber |
Working Conditions | Temperature: (-25-+70)°C Humidity: (20-93)%RH |
Storage Condition | Temperature: (-25-+70)°C |
Protection Level | IP55 Gasket |
Weight | 0.75kg |
DISPLAY
3.1 PUSHBUTTONS
| Stop| Stop running generator in remote mode; During stopping process,
press this button again to stop generator immediately.
---|---|---
| Start| Start genset in remote mode.
| Sound Alarm Acknowledge| In case of sound alarm pressing this button will
mute the panel buzzer.
| Light
Alarm
Acknowledge| In case of alarm pressing this button will return flash indicator
to its illuminating condition.
| Lamp Test| Pressing this button will illuminate all the LED indicators on
the panel and highlight the LCD monitor.
| Brightness+| Pressing and holding this button can increase brightness of LCD
monitor and LED indicators.
| Brightness-| Pressing and holding this button can decrease brightness of LCD
monitor and LED indicators.
| Up/Increase| Scroll the screen up.
| Down/Decrease| Scroll the screen down.
| Left| Scroll the pages left.
| Right| Scrolls the pages right.
| Homepage| Press this button to return to the home page; In settings menu
press this button to save changes.
| Settings| Press this button to enter into settings screen;
In settings menu press this button to return to previous menu.
3.2 LCD DISPLAY
Data displayed on the LCD is obtained from HMC9000 via CANBUS port. Press to
switchover between the pages of the monitor. Press to return to the
home page and to enter into parameter configuration pages.
3.2.1 MAIN DISPLAY (HOME PAGE)
The main screen displays engine speed, coolant temperature, oil pressure, two
batteries voltage and engine status. The main screen looks as follows:
3.2.2 DATA DISPLAY
The main screen is divided into two separate viewing areas: left and right.
Left area has only one page and shows diesel engine operation status and
battery status; press to view the right area. Right area is divided into
pages: engine page, alarm page, expansion module data page and event log page
etc.
-
Engine page
Displays engine speed, sensors 1-8 values, main battery voltage, standby battery voltage, charger voltage, GOV output ratio, total run time and total start times.
For J1939 engines, an additional ECU page will be displayed. ECU data includes coolant pressure, coolant level, fuel temperature, fuel pressure, inlet temperature, exhaust temperature, turbo pressure, fuel consumption, total fuel consumption etc (Different engine with different parameters). -
Alarm page:
It displays all kinds of warning alarms and shutdown alarms which detected by controller. -
Other parameters page
HMC9000 main controller’s date and time, inputs/outputs status.
OPERATION
Press and input the password to enter into parameter configuration menu.
Configurable parameters include displayed language, operation mode and
password.
The module has two operation modes:
- Monitor mode, in which and buttons have no effect.
- Control mode, in which the engine can be stopped and started by press and pushbuttons; this mode activates only if HMC9000 is in remote mode.
4.1 REMOTE START/STOP PROCEDURE
Remote mode is selected by pressing the button; a LED besides the button will
illuminate to confirm the operation;
-
Remote start
Press button to start the gen-set, then preheat delay, safety on delay, start idle delay and warming up delay will be displayed on the screen in turn (according to the engine settings); -
Remote stop
Press button, then the screen will display cooling down delay, stop idle delay, ETS delay and fail to stop delay in turn (according to the engine settings); Note: If an alarm condition occurs during starting or stopping procedure, alarm information will be synchronously displayed on HRM3300 LCD.
4.2 ACKNOWLEDGE OPERATION
In case of alarm pressing and buttons will mute the panel buzzer and return flash indicator to its illuminating condition. In case of new alarm situation, sound alarm will be initiated again and the light indicator will start flashing and the user will have to press the acknowledge buttons again to clear them.
BACK PANEL
HRM3300 controller back panel is shown below:
Terminal connections description:
Terminal | Function | Cable Size | Description |
---|---|---|---|
1 | B- | 1.0mm2 | Power supply negative input. |
2 | B+ | 1.0mm2 | Power supply positive input. |
3 | NC | Not connected | |
4 | SCR (REMOTE) | 0.5mm2 | A CANBUS port which communicate |
with main control. Impedance-1200
shielded wire with its one end connected to ground is recommended. There is
1200 terminal resistance
inside already; if needed, make
5| CAN(H) (REMOTE)
6| CAN(L) (REMOTE)
7| RE (120Ω
resistance)| | terminal 6, 7 short circuits.
| USB| | Factory use
APPLICATION DIAGRAM
HRM3300 Application Diagram
INATALLATION
Controller is panel built-in design; it is fixed by clips when installed. The controller’s overall dimensions and cutout dimensions for panel, please refers to as following,
HRM3300 Remote Control