RAB ALED 260W/360W Energy Efficient LED Light Instructions

June 8, 2024
RAB

RAB logo ALED 260W/360W Energy Efficient LED
Light InstructionsRAB ALED 260W 360W Energy Efficient LED
Light ALED 260W / 360W

ALED 260W/360W Energy Efficient LED Light

INSTRUCTIONS
ALED® 260W 360W INSTALLATION
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.
CAUTION: The fixture weighs 80lbs. Make sure pole and hardware supplied by others (if any) can withstand the weight of the fixture.

MOUNTING ARM ON FIXTURE

  1. Remove the Arm Cover from the Arm.
  2. Feed wires from Fixture through Gasket into Arm.
  3. Line up Arm and Fixture. Place flat washers, lock washers and nuts on the Short 3/8-16 Bolts inside the Arm and tighten securely to housing.
  4. Make sure the Gasket is secure between Arm and Fixture.RAB ALED 260W 360W Energy Efficient LED Light - fig 1

MOUNTING FIXTURE DIRECTLY TO POLE

Check that pole is drilled according to Pole Drawing Detail.

  1. Remove the Arm Cover from the Arm.
  2. Feed wires from Fixture through Gasket into Arm. Feed supply wires from Pole through Gasket into Arm.
  3. Insert Long 3/8-16 Bolts through Arm, Gasket, Pole and thread into the Bolster Plate. Be sure the Gasket is between the Arm and Pole and secure with bolts, washers and lockwashers.
  4. Make necessary connections inside the Arm and knot wires for strain relief.
  5. Replace the Arm Cover. Be sure the Gasket on Arm Cover is in place. Tighten Screws (2) and add the Plugs. Secure Pole Cap.

ROUND POLE ADAPTOR ACCESSORY
For use with standard RAB pole drilling.

  1. Drill round pole using the dimensions shown in the Pole Drilling Detail.
  2. Place Round Pole Adaptor/ RPA (ordered separately) and RPA Gasket between the Fixture and drilled Pole as shown.
  3. Line up top holes of the Gaskets and Round Pole Adaptor with top hole in the Pole Drilling Pattern.
  4. Place Long 3/8” Bolts from the ALED through the top hole of the RPA and Gaskets to the Round Pole thread into Bolster Plate.
  5. Feed wires from Fixture through Gasket into Arm. Feed supply wires from Pole through Gasket into Arm. Make necessary connections inside the Arm and knot wires for strain relief.
  6. Replace the Arm Cover, tighten Screws and add the Plugs. Secure Pole Cap.
    RAB ALED 260W 360W Energy Efficient LED Light - fig 3

0-10V DIMMABLE WIRING
Universal voltage driver permits operation at 120V thru 277V, 50 or 60 Hz. For 0-10V Dimming follow the wiring directions shown below.

  1.  Connect the black fixture lead to the (+) LINE supply lead.
  2. Connect the white fixture lead to the (-) COMMON supply lead.
  3. Connect the GROUND wire from fixture to supply ground. Do NOT connect the GROUND of the dimming fixture to the output.
  4. Connect the purple fixture lead to the (V+) DIM lead.
  5. Connect the pink (or gray) fixture lead to the (V-) DIM lead.
  6. Cap the yellow fixture lead, if present. Do NOT connect.RAB ALED 260W 360W Energy Efficient LED Light - fig 4

PHOTOCELL INSTALLATION

Photocell may be installed in the field. Apply weatherproof silicone sealant to all plugs and unused conduit entries.

  1. Knockout hole on top of arm.
  2. Install photocell and wire as per diagram.
  3. Use photocell rated for your supply voltage.

POLE DRILLING DETAIL
For non-RAB poles use these dimensions to drill the pole. This template is not to scale. Please use measurements shown below.RAB ALED 260W 360W Energy
Efficient LED Light - fig 6

CLEANING & MAINTENANCE

CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized.

  1. Clean glass lens with non-abrasive glass cleaning solution.
  2. Do not open the fixture to clean the LED. Do not touch the LED.

TROUBLESHOOTING

  1. Check that the line voltage at the fixture is correct. Refer to wiring directions.
  2. Is the fixture grounded properly?
  3. Is the photocell, if used, functioning properly?

Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com

RAB logoEasy Answers
rablighting.com
Visit our website for product info
Tech Help Line
Call our experts: 888 722-1000
e-mail  Answered promptly – sales@rablighting.com
Free Lighting Layouts
Answered online or by request
ALED 260W/360W – IN – 1121
RAB WARRANTY: RAB’s warranty is subject to all terms and conditions found at rablighting.com/warranty.
73391-RAB

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals