PETERMANN X-Ray Mat User Manual
- June 8, 2024
- PETERMANN
Table of Contents
PETERMANN X-Ray Mat User Manual
General Information
Thank you for choosing a Peterman product.
Please read the user manual carefully before using the product for the first time!
The current understanding in modern occupational health and safety is that
people in nursing professions experience significant work-related physical
strain. Back injuries are common.
There are many situations in which a patient has to be transferred from a bed,
a wheeled stretcher, ambulance stretcher, an X-Ray table or a wheelchair to a
different stretcher or seat. The strain on the user and the patient / care-
dependent can be reduced significantly through the use of transfer aids.
The use of transfer aids should be conditional upon the user having learned to
use the equipment properly.
The user has to decide for themselves what equipment is suitable to the
patient’s situation and the intended sequence of movements.
The X-Ray Mats are part of a product line which was developed specifically as
X-ray table pads for moving patients.
The product may only be used for the specified purpose and under the specified
conditions.
The information in this user manual is for the patient who is being
transferred and moved, as well as the user performing the transfer / position
change.
Contact us if you require additional information or assistance using the
Peterman product.
Product versions
- Item no.: PMF-8200 X-Ray Mat 650 mm
- Item no.: PMF-8220 X-Ray Mat 850 mm
Accessories
No accessories are available for this device.
Scope of delivery
- X-Ray Mat
- User manual
Storage, transport
- Store/transport: at -5°C – 40 C
- Other: protect from sunlight.
Service life/lifecycle
If the product is used in accordance with the safety instructions, then the
expected product service life is five years.
However, the effective service life may vary depending on the frequency and
intensity of use and the number of cleaning and disinfection cycles.
Perform regular function checks on the product and be sure to observe the
safety information (see item 2)
Safety information
WARNING: indicates a potential danger which could lead to personal injury or material damage.
- It is the responsibility of the organization / the user to determine, on the basis of the circumstances (weight / health condition of the patient) and the capabilities of the user, whether several users may be required for the transfer and/or whether additional safety measures are required.
- Defective products may no longer be used.
- Please note that if the X-ray imaging extends over the side handles of the mat, then the seam of the handle strip may be visible.
- The smooth bottom significantly reduces resistance due to friction during repositioning. Ensure that the patient is in a safe position!
- Never leave the patient lying on the X-Ray Mat unattended.
- Ensure that the transfers are performed by the users in a back-friendly manner.
- Weight limits must be observed (200 kg).
Symbols used
| Wipe off| | max. load capacity see item 6
---|---|---|---
| Do not bleach| | Manufacturer
| Do not tumble| | Batch no. / lot no.
| Do not iron| | Identification code
| Do not dry clean| | Conformity mark
| Warning| | Item number
| Observe the user manual| | Medical device label
Function check
Repositioning products are also subject to a natural ageing process. Inspect
the aids regularly and carefully.
Ensure that the product is in sound condition and that the material is not
damaged.
The smooth surface of the special sliding material allows for easy sliding and
moving.
Check these properties – ideally in comparison to a new product.
Defective products may no longer be used!
Using the product
Indication and further use
Due to the wide range of possible applications, the indications cannot be tied
to a specific clinical picture, since XRay mats as an X-ray table support are
suitable for all applications involving people who require assistance.
This product may be reused.
Before reusing the product, be sure to perform a thorough function check (see
item 2.2) as well as cleaning or disinfection of the product. (see item 5)
Contraindications
Contraindications cannot be tied to a specific clinical picture. Observe the safety information under item 2.
Application risks
- Excessively fast movements → risk of falling
Areas of application
The product can be used in health care facilities with x-ray equipment’s.
Application illustration
Application
The X-Ray Mat has been specifically designed as X-ray table pad for the
repositioning of patients. The pleasant surface and the padding offer the
patient a comfortable support during radiography.
The handles on the side of the X-Ray Mat enable one or more users to adjust
its position and to position the patient accurately and in a back-safe manner.
The material of the X-Ray Mat is fully radiolucent.
**** Please note that if the X-ray imaging extends over the side handles of the mat, then the seam of the handle strip may be visible.
Visit our website at www.pm-med.de or watch our
comprehensive product videos on our YouTube channel.
Scan Me
Approved accessories, combination with other products
Peterman transfer aids are part of a comprehensive aid product range, which
are effective and back-friendly for the user and comfortable and supportive
for the patients.
Additional Peterman products may be used according to the situation and
clinical picture. Ask our experts. We are happy to help you!
Product marking / CE
The Petermann X-Ray Mat is a Class I Medical Device and meets the EU-
Regulation 2017/745 of the European Parliament and Council dated 05.04.2017
for medical devices, also called MDR.
Petermann GmbH is certified in accordance with DIN EN ISO 13485 by TÜV Süd,
Medical Devices – Quality management systems applicable to the design and
development, production and distribution of aids for people of limited
mobility.
Cleaning, care and disinfection
All Petermann repositioning and transfer aids can be wet cleaned. Use warm
water and a mild cleaning agent.
If applicable, wipe the product off with a moist cloth and then let it dry
thoroughly.
Don’t use any scouring or bleaching agents or any sharp-edged objects for
cleaning.
When necessary, we recommend wipe disinfection with the product Trionic®
(DGHM/VAH approval, further information upon request). As alternatives to our
proven disinfectant Trionic®, we can also recommend the following
disinfectants for wipe disinfection:
- Mikrobac® Tissues*
- Mikrobac® forte*
- Bacillol® 30 Foam
- Bacillol® 30 Tissues
When using products marked with an *, wipe down again using a water-soaked
cloth after disinfection has been completed, in order to remove residues and
prevent build-up.
For wipe disinfection, please be sure to always follow the instructions
provided by the manufacturer.
Always follow the care instructions on the label of every product as well as
the information in the respective user manual.
Technical Data
Item no. | Material | Colour | Load-bearing capacity |
---|---|---|---|
PMF-8200 | PVC/PES, latex free | blue | 200 kg |
PMF-8220 | PVC/PES, latex free | blue | 200 kg |
Item no. | Description | Dimensions in mm | Weight |
--- | --- | --- | --- |
PMF-8200 | X-Ray Mat | 1900 x 650 x 30 | 2650 g |
PMF-8220 | X-Ray Mat | 1900 x 850 x 30 | 3300 g |
The manufacturing of our products is subject to highest quality standards.
Due to usual manufacturing variations published dimensions and further
information concerning the condition of the product are defined as target
production specifications.
Deviations which might occur are monitored by professional quality management
procedures and do not represent a reduction in performance of the respective
product.
Warranty
- The company Peterman warrants that the product is free from defects in material and workmanship.
- The warranty period is 3 years. It does not cover defects attributable to abrasion, normal wear, improper use or improper cleaning.
- The company Peterman is not liable for accidental or consequential injury or material damage.
Disposal Information
There are no specific disposal regulations X-Ray Mats, they can be disposed of in accordance with applicable national and local regulations.
CUSTOMER SUPPORT
etermann GmbH
Waldweg 3
D-91601 Dombühl
Phone: +49 (0) 9868-9339-0
Email: petermann@pm-med.de
References
- med.de - Ihr Medizinportal | Chirurgie | Krankheiten | Gesundheit | Arztsuche
- Innovative Hilfsmittel - Manuellen Transferhilfen - Petermann DE
Read User Manual Online (PDF format)