PETERMANN X-Ray Mat User Manual

June 8, 2024
PETERMANN

PETERMANN X-Ray Mat User Manual
PETERMANN X-Ray Mat

General Information

Thank you for choosing a Peterman product.

Please read the user manual carefully before using the product for the first time!

The current understanding in modern occupational health and safety is that people in nursing professions experience significant work-related physical strain. Back injuries are common.
There are many situations in which a patient has to be transferred from a bed, a wheeled stretcher, ambulance stretcher, an X-Ray table or a wheelchair to a different stretcher or seat. The strain on the user and the patient / care- dependent can be reduced significantly through the use of transfer aids.
The use of transfer aids should be conditional upon the user having learned to use the equipment properly.
The user has to decide for themselves what equipment is suitable to the patient’s situation and the intended sequence of movements.
The X-Ray Mats are part of a product line which was developed specifically as X-ray table pads for moving patients.
The product may only be used for the specified purpose and under the specified conditions.
The information in this user manual is for the patient who is being transferred and moved, as well as the user performing the transfer / position change.
Contact us if you require additional information or assistance using the Peterman product.

Product versions
  • Item no.: PMF-8200 X-Ray Mat 650 mm
  • Item no.: PMF-8220 X-Ray Mat 850 mm
Accessories

No accessories are available for this device.

Scope of delivery
  • X-Ray Mat
  • User manual

Storage, transport

  • Store/transport: at -5°C – 40 C
  • Other: protect from sunlight.
Service life/lifecycle

If the product is used in accordance with the safety instructions, then the expected product service life is five years.
However, the effective service life may vary depending on the frequency and intensity of use and the number of cleaning and disinfection cycles.
Perform regular function checks on the product and be sure to observe the safety information (see item 2)

Safety information

WARNING: indicates a potential danger which could lead to personal injury or material damage.

  • It is the responsibility of the organization / the user to determine, on the basis of the circumstances (weight / health condition of the patient) and the capabilities of the user, whether several users may be required for the transfer and/or whether additional safety measures are required.
  • Defective products may no longer be used.
  • Please note that if the X-ray imaging extends over the side handles of the mat, then the seam of the handle strip may be visible.
  • The smooth bottom significantly reduces resistance due to friction during repositioning. Ensure that the patient is in a safe position!
  • Never leave the patient lying on the X-Ray Mat unattended.
  • Ensure that the transfers are performed by the users in a back-friendly manner.
  • Weight limits must be observed (200 kg).

Symbols used

| Wipe off| | max. load capacity see item 6
---|---|---|---
| Do not bleach| | Manufacturer
| Do not tumble| | Batch no. / lot no.
| Do not iron| | Identification code
| Do not dry clean| | Conformity mark
| Warning| | Item number
| Observe the user manual| | Medical device label

Function check

Repositioning products are also subject to a natural ageing process. Inspect the aids regularly and carefully.
Ensure that the product is in sound condition and that the material is not damaged.
The smooth surface of the special sliding material allows for easy sliding and moving.
Check these properties – ideally in comparison to a new product.

Defective products may no longer be used!

Using the product

Indication and further use

Due to the wide range of possible applications, the indications cannot be tied to a specific clinical picture, since XRay mats as an X-ray table support are suitable for all applications involving people who require assistance.
This product may be reused.
Before reusing the product, be sure to perform a thorough function check (see item 2.2) as well as cleaning or disinfection of the product. (see item 5)

Contraindications

Contraindications cannot be tied to a specific clinical picture. Observe the safety information under item 2.

Application risks
  • Excessively fast movements → risk of falling
Areas of application

The product can be used in health care facilities with x-ray equipment’s.

Application illustration
Application

The X-Ray Mat has been specifically designed as X-ray table pad for the repositioning of patients. The pleasant surface and the padding offer the patient a comfortable support during radiography.
The handles on the side of the X-Ray Mat enable one or more users to adjust its position and to position the patient accurately and in a back-safe manner.
The material of the X-Ray Mat is fully radiolucent.

**** Please note that if the X-ray imaging extends over the side handles of the mat, then the seam of the handle strip may be visible.

Visit our website at www.pm-med.de or watch our comprehensive product videos on our YouTube channel.
Scan Me
QR. Code

Approved accessories, combination with other products

Peterman transfer aids are part of a comprehensive aid product range, which are effective and back-friendly for the user and comfortable and supportive for the patients.
Additional Peterman products may be used according to the situation and clinical picture. Ask our experts. We are happy to help you!

Product marking / CE

The Petermann X-Ray Mat is a Class I Medical Device and meets the EU- Regulation 2017/745 of the European Parliament and Council dated 05.04.2017 for medical devices, also called MDR.
Petermann GmbH is certified in accordance with DIN EN ISO 13485 by TÜV Süd, Medical Devices – Quality management systems applicable to the design and development, production and distribution of aids for people of limited mobility.

Cleaning, care and disinfection

All Petermann repositioning and transfer aids can be wet cleaned. Use warm water and a mild cleaning agent.
If applicable, wipe the product off with a moist cloth and then let it dry thoroughly.
Don’t use any scouring or bleaching agents or any sharp-edged objects for cleaning.
When necessary, we recommend wipe disinfection with the product Trionic® (DGHM/VAH approval, further information upon request). As alternatives to our proven disinfectant Trionic®, we can also recommend the following disinfectants for wipe disinfection:

  • Mikrobac® Tissues*
  • Mikrobac® forte*
  • Bacillol® 30 Foam
  • Bacillol® 30 Tissues

When using products marked with an *, wipe down again using a water-soaked cloth after disinfection has been completed, in order to remove residues and prevent build-up.
For wipe disinfection, please be sure to always follow the instructions provided by the manufacturer.
Always follow the care instructions on the label of every product as well as the information in the respective user manual.

Technical Data

Item no. Material Colour Load-bearing capacity
PMF-8200 PVC/PES, latex free blue 200 kg
PMF-8220 PVC/PES, latex free blue 200 kg
Item no. Description Dimensions in mm Weight
--- --- --- ---
PMF-8200 X-Ray Mat 1900 x 650 x 30 2650 g
PMF-8220 X-Ray Mat 1900 x 850 x 30 3300 g

The manufacturing of our products is subject to highest quality standards.
Due to usual manufacturing variations published dimensions and further information concerning the condition of the product are defined as target production specifications.
Deviations which might occur are monitored by professional quality management procedures and do not represent a reduction in performance of the respective product.

Warranty

  • The company Peterman warrants that the product is free from defects in material and workmanship.
  • The warranty period is 3 years. It does not cover defects attributable to abrasion, normal wear, improper use or improper cleaning.
  • The company Peterman is not liable for accidental or consequential injury or material damage.

Disposal Information

There are no specific disposal regulations X-Ray Mats, they can be disposed of in accordance with applicable national and local regulations.

CUSTOMER SUPPORT

etermann GmbH
Waldweg 3
D-91601 Dombühl
Phone: +49 (0) 9868-9339-0
Email: [email protected]
Logo.png

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

PETERMANN User Manuals

Related Manuals