EVERBILT SBA033V1 Submersible Sump Pump User Guide

June 4, 2024
Everbilt

EVERBILT SBA033V1 Submersible Sump Pump

EVERBILT-SBA033V1-Submersible-Sump-Pump

Instructions

  1. Ensure basin is clear of all debris and place pump on hard level surface (not dirt or gravel). 14” x 22” minimum basin size required. EVERBILT-SBA033V1-Submersible-Sump-Pump-1
  2. Measure, cut and install discharge fittings, check valve, and piping. Drill a 3/16” hole in the discharge pipe, level with the top of the pump.EVERBILT-SBA033V1-Submersible-Sump-Pump-2
  3. Plug Pump in to GFCI outlet on dedicated circuit with 15 amp breakerEVERBILT-SBA033V1-Submersible-Sump-Pump-3
  4. Test operation by adding water until float rises, pump turns on, and the water level drops. Float will lower with the water level and turn the pump off.EVERBILT-SBA033V1-Submersible-Sump-Pump-4
  5. Install optional basin cover. EVERBILT-SBA033V1-Submersible-Sump-Pump-5