TRIPP-LITE PDUNV 1.9-3.8kW Saingle-Phase 120-240V Basic PDU 14 Outlets C20 with 5 Adapters Owner’s Manual
- June 8, 2024
- Tripp Lite
Table of Contents
**TRIPP-LITE PDUNV 1.9-3.8kW Single-Phase 120-240V Basic PDU 14 Outlets C20 with 5 Adapters Owner’s Manual
**
Package Contents
Highlights
- C20 input with 10-ft. (3.05 m) cord and 5 adapters
- 14 total outlets—12 C13 and 2 C19
- Switchless design prevents accidental shutdown
- Reversible all-metal housing
- 16A circuit breaker protects against overloads.
Package Includes
- Phase 120-240V Basic PDU
- (5) C19 plug adapters
- Mounting brackets
- Owner’s manual
Versatile 16A 120-240V PDU compatible with wide range of voltages to deliver single-phase AC power to multiple loads from a utility outlet, generator or UPS system. Recommended for data centers, server rooms and network closets.
Description
The PDUNV 1.6/3.8kW Single-Phase 120-240V Basic PDU is a versatile no-frills unit for data centers, server rooms and network wiring closets. Perfectly suited for high-density IT environments, the PDUNV features 14 total outlets—four C13 in front and eight C13 and two C19 in the rear.
The C20 input plug with 10-ft. (3.05 m) cord connects to your facility’s compatible AC power source, generator or protected UPS to distribute power to connected equipment. Five C19 plug adapters with locking retainer clips are included for connection in a variety of power environments. The adapters convert the plug to C14 (connects to C13 120-240V), NEMA L6-20P (L6-20R 20A 208/240V), NEMA L5-20P (L5- 20R 20A 120V), NEMA 5-20P (5-20R 20A 120V) or NEMA 5-15P (5-15R 15A 120V).
The switchless design prevents an accidental shutdown, which could lead to costlydowntime. A 16A circuit breaker protects connected equipment from dangerous overloads. The reversible all-metal housing supports a variety of mounting options, including 1U horizontal or 0U vertical mounting in EIA- standard 19-inch racks, under a counter or on a wall or workbench with user- supplied hardware. It also supports toolless 0U vertical mounting with the optional PDUSIDEBRKT (sold separately).
Features
Reliable Single-Phase 16A 120-240V Power Distribution
- Versatile no-frills PDU for data centers, server rooms and network wiring closets
- 14 total outlets—4 C13 in front, 8 C13 and 2 C19 in rear
- C20 input with 10-ft. (3.05 m) cord and 5 plug adapters
- Rear-panel grounding lug
- 16A circuit breaker protects against overloads
C19 Plug Adapters Included
- For connecting to AC power in various power environments
- Locking retainer clips included
- Adapters: C14, NEMA L6-20P, NEMA L5-20P, NEMA 5-20P and NEMA 5-15P
Switchless Design
- Prevents accidental shutdowns and costly downtime.
Versatile Installation Options
- Reversible all-metal housing faces front or rear in rack
- Supports 1U horizontal or 0U vertical mounting in EIA-standard 19 in. racks
- Also mounts on wall, workbench or under a counter
- Supports toolless 0U vertical mounting with optional PDUSIDEBRKT (sold separately)
Specifications
OVERVIEW
|
---|---
| UPC Code| 037332127204
| PDU Type| Basic
| INPUT
| PDU Input Voltage| 120; 125; 127; 200; 208; 220; 230; 240
| Recommended Electrical Service| Single-phase 16/20A 120-240V service
| Maximum Input Amps| 16
| Input Connection Type| C20 inlet accepts included C19-C20 cable with
included plug adapters
| PDU Plug Type| NEMA 5-15P; NEMA 5-20P; NEMA L5-20P; NEMA L6-20P; IEC-320
C14; IEC-320 C20
| Input Phase| Single-Phase
| Input Cord Length (ft.)| 10
| Input Cord Length (m)| 3.05
| OUTPUT
| Output Capacity Details| 3.84kW (240V), 3.68kW (230V), 3.52kW (220V),
3.33kW (208V), 3.2kW (200V), 2.03kW (127V), 1.92kW (120V) /16A total capacity;
16A max per C19 outlet; 12A (10A CE) max per C13 outlet
| Frequency Compatibility| 50 / 60 Hz
| Output Receptacles| (12) C13; (2) C19
| Output Nominal Voltage| 120-240V
| Overload Protection| 16A circuit breaker
| SURGE / NOISE SUPPRESSION
| Automatic Shut-Off| No
| PHYSICAL
| Material of Construction| Metal
| Form Factors Supported| 1U rackmount, 0U vertical mount, wallmount and
under-counter mounting supported
| Minimum Required Rack Depth (cm)| 19.81
| Minimum Required Rack Depth (inches)| 7.8
| Outlets Measurement (Center to Center)| Distance between Front (C13) outlets
= 28.75mm; Distance between Rear (C19) outlets = 55mm; Distance between Rear
(C13) outelts = 28.75mm
| PDU Form Factor| Horizontal (1U)
| Shipping Dimensions (hwd / in.)| 2.40 x 11.00 x 20.20
Shipping Dimensions (hwd / cm)| 6.10 x 27.94 x 51.31
Shipping Weight (lbs.)| 7.00
Shipping Weight (kg)| 3.18
Unit Dimensions (hwd / in.)| 1.750 x 19.000 x 4.250
Unit Dimensions (hwd / cm)| 4,44 x 44,45 x 10,8
Unit Weight (lbs.)| 3.20
Unit Weight (kg)| 1.45
ENVIRONMENTAL
Operating Temperature Range| 0C ~ 40C (32F ~ 104F)
Storage Temperature Range| -30°C to +50°C (-22°F to +122°F)
Relative Humidity| 5-95% non-condensing
Operating Elevation (ft.)| 0-10,000
Operating Elevation (m)| 0-3000
FEATURES & SPECIFICATIONS
TVSS Grounding| Grounding lug
STANDARDS & COMPLIANCE
Product Certifications| IEC 62368-1; CAN/CSA-C22.2 No. 107.1 (Canada); UL
62368-1
Product Compliance| RoHS; CE (Europe); FCC Part 15 Class A (USA)
WARRANTY & SUPPORT
Product Warranty Period (Worldwide)| **** 5-year limited warranty
© 2022 Eaton. All Rights Reserved.
Eaton is a registered trademark.
All other trademarks are the property of their respective owner
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>