LARK 83196 Luminaire Instruction Manual
- June 8, 2024
- LARK
Table of Contents
83196 Luminaire
Instruction Manual
Mounting Instruction
Item no: 83196
- Find a clear area in which you can work.
- Unpack fixture and glass from carton.
- Carefully review instructions prior to assembly.
Shut off electrical current before starting. If the fixture you are replacing is turned on and off by a wall switch, simply turn the switch off. If not, remove the appropriate fuse (or open the circuit breakers) until the fixture is dead.DO NOT restore current – either by fuse, breaker, or switch until the new fixture is completely wired and in place.
- Determine the desired height the pendant will be installed.
- The fixture is supplied with assorted stem sizes. Determine what combinations of stems are needed to achieve desired length. see Drawing 1
- Slip stems over wire and thread first stem onto top of pendant, longest stem first. Repeat this process until all required stems are threaded together.
- Slip wire through center hole of canopy swivel and thread swivel onto the top of the last stem installed.
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY
ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW
WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR
CODE REQUIREMENTS.
Make electrical connections from supply wire to fixture lead wires. Refer to
instruction sheet (I.S. 18) and follow all instructions to make all necessary
wiring connections. Then refer back to this sheet to complete installation of
this fixture.
Mounting Plate Installation Instructions
ADDITIONAL ANCHOR POINTS
DRAWING 1- INSPECTION CABLES
Item No. 83196
IMPORTANT: THIS FIXTURE/SIN EXCESS OF 30 LBS. AND
IT IS RECOMMENDED THAT THIS FIXTURE BE MOUNTED INDEPENDENTLY OF THE JUNCTION
BOX. THE MOUNTING PLATE MUST BE MOUNTED TO THE CEILING USING APPROPRIATE
MOUNTING HARDWARE AND BE MOUNTED TO A JOIST OR OTHER STRUCTURE THAT WILL
PROPERLY SUPPORT THE WEIGHT.
NOTE: USE THE APPROPRIATE HARDWARE FOR ANCHORING. DIFFERENT MATERIALS
REQUIRE DIFFERENT HARDWARE. IT IS UP TO THE INSTALLER TO ACQUIRE THE REQUIRED
HARDWARE AND TO ENSURE THE FIXTURE IS INSTALLED INDEPENDENTLY OF THE JUNCTION
BOX.
INSPECTION CABLES
This luminaire is supplied with inspection cablesthat can be hooked onto the
canopy to ease the wiring process during installation
see Drawing 1.
To attach the inspection cables, lift the fixture up, assistance is
recommended, and hook the cable from the mounting plate to the tab in the
canopy. After attaching all the cables the fixture can hang while the wiring
is completed.
After wiring is completed see mounting instructions supplied to finish
installation.
DRAWING1- CANOPY ASSEMBLY
DRAWING 2 – MOUNTING
DRAWING 3 – MOUNTING
wiring grounding instructions
Drawing 1- Flush Moun
Drawing 2-Chain Hun
Drawing 3- Post-Mount
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (IS 18) AND ANY ADDITIONAL DIRECTIOTURN POWER SUPPLY OFF DURING INSTALLATION. IF WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICLOCAL AUTHORITIES FOR CODE REQUIREMENTS.
wiring instructions
Indoor Fixtures
- Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B)with appropriately sized twist on connector – see Drawings 1 or 2.
- Connect negative supply wire (Cl (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
- Please refer to the grounding instructions below to complete all electrical connections
Outdoor Fixtures
-
Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Drawings 2 or 3.
-
Connect negative supply wire (Cl (typically white or the ribbed, markeside of the two-conductor cord) to negative fixture lead (D).
-
Cover open end of connectors with silicone sealant to form a watertight seal. If installing a wall mount fixture, use caulk to seal gaps between the
fixture mounting plate (backpla te) and the wall. This will help prevenwater from entering the out let box. If the wal I surface is lap siding, ucaulk and a fixture mounting platform specially. -
Please refer to the grounding instructions below to complete allelectrical connections.
grounding instructions
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture
ground wire ( E) (typically copper or green plastic coated) to the fixture
mounting strap (M) with the ground screw (S) see Drawing 1.
Note: On straps for screw supported fixtures, first install the two
mounting
Chain Hung Fixtures
Loop fixture ground wire (E) (typicallycoppe r or green plastic coated) under
the head of the ground screw (S) on fixture mounting strap (M) and connect to
the loose end of the fixture ground wire directly to the ground wire of the
building system with appropriately sized twist-on connectors-see Drawing 2.
Post-Mou nt Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to
power supply ground with appropriately sized twist-on connector inside post.
Cover open end of connector with silicone sealant to form a watertight seal –
see Drawing 3.
LARK 33000 PIN OAK PARKWAY, AVON LAKE, OH 44012
Larkliving.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>