Dimension

Dimension

Operation

Installation

Installation

  • Mount the faucet on the washbasin (ø 28–35 mm). Ensure that the o-ring is in it’s slot at the bottom of the raising part.
  • Put the fixing washer (1) and stud nuts (2) in place and tighten the nuts (SW 9 mm). If necessary use the extension screws.
  • Remove the control box cover.
  • Using the four screws supplied, mount the control box (3) onto a suitable place in the cabinet or on the wall below the washbasin, in a position that permits easy access for maintenance.
  • Cut the hose (4) to the proper length.
  • Attach the hose to the connector (5) on the control box.
  • Secure the hose with a hose clamp (6).

Electrical connections

  • Connect the photocell wire (8) to the control box and tighten the cable gland with the nut (9).
  • Connect the 24 V voltage as follows:
  • Remove the connector (10) e.g. by prying off with a small screwdriver.
  • Make sure that the electric wires are not live and then attach them to the connector.
  • Push the connector and wires back into the counterpart.
  • Pull any loose wire through the cable gland and out of the control box. Tighten the cable gland (11) nut.
  • Turn on the water supply to the faucet.
  • Check that the connections are waterproof and that the faucet operates by putting your hand in front of the photocell (12).
  • Replace the control box cover.

PLEASE NOTE!
When connecting the voltage to the appliance, the solenoid valve will always be open for a moment.

Cleaning the Filter (see figures 1 and 2)
If the water flow has decreased, this may be because the filter is dirty. Clean the filter as follows:

  • Shut off the water supply to the faucet.
  • Remove the connecting hose from the control box.
  • Unscrew the connecting nipple (7) and remove the filter from the nipple.
  • Clean the filter under running water.
  • Reassemble the parts.

Troubleshooting

Symptom Cause / Solution

Water flow doesn’t stop until 8 seconds even if the flow period is set smaller

  • The sensing range is too long
  • Check that the photocell is clean
  • The solenoid valve is damaged

Water flow is low and weak

  • Filter is dirty

No water comes out of the faucet

  • Check the water supply to the control box

  • The solenoid valve is damaged
    Power failure

  • The photocell is covered or damaged

Flow period is too long or short

  • Adjust the flow period