oras Electra 6130 Faucet Washbasin Installation Guide

June 3, 2024
Oras

oras Electra 6130 Faucet Washbasin Installation Guide


Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc., registered in the U.S. and other countries.
Google Play and the Google Play logo are trademarks of Google Inc.
The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use of such marks by Oras Group is under license. Other trademarks and trade names are those of their respective owners.

Dimension

Dimension

Operation

Installation

Installation

  • Mount the faucet on the washbasin (ø 28–35 mm). Ensure that the o-ring is in it’s slot at the bottom of the raising part.
  • Put the fixing washer (1) and stud nuts (2) in place and tighten the nuts (SW 9 mm). If necessary use the extension screws.
  • Remove the control box cover.
  • Using the four screws supplied, mount the control box (3) onto a suitable place in the cabinet or on the wall below the washbasin, in a position that permits easy access for maintenance.
  • Cut the hose (4) to the proper length.
  • Attach the hose to the connector (5) on the control box.
  • Secure the hose with a hose clamp (6).

Electrical connections

  • Connect the photocell wire (8) to the control box and tighten the cable gland with the nut (9).
  • Connect the 24 V voltage as follows:
  • Remove the connector (10) e.g. by prying off with a small screwdriver.
  • Make sure that the electric wires are not live and then attach them to the connector.
  • Push the connector and wires back into the counterpart.
  • Pull any loose wire through the cable gland and out of the control box. Tighten the cable gland (11) nut.
  • Turn on the water supply to the faucet.
  • Check that the connections are waterproof and that the faucet operates by putting your hand in front of the photocell (12).
  • Replace the control box cover.

PLEASE NOTE!
When connecting the voltage to the appliance, the solenoid valve will always be open for a moment.

Cleaning the Filter (see figures 1 and 2)
If the water flow has decreased, this may be because the filter is dirty. Clean the filter as follows:

  • Shut off the water supply to the faucet.
  • Remove the connecting hose from the control box.
  • Unscrew the connecting nipple (7) and remove the filter from the nipple.
  • Clean the filter under running water.
  • Reassemble the parts.

Troubleshooting

Symptom Cause / Solution

Water flow doesn’t stop until 8 seconds even if the flow period is set smaller

  • The sensing range is too long
  • Check that the photocell is clean
  • The solenoid valve is damaged

Water flow is low and weak

  • Filter is dirty

No water comes out of the faucet

  • Check the water supply to the control box

  • The solenoid valve is damaged
    Power failure

  • The photocell is covered or damaged

Flow period is too long or short

  • Adjust the flow period

Download the App

Connecting

Oras App

QR Code
apps.oras.com

Safety Instructions


cleaning.oras.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals