RAB HA4 HALED Modular Downlight Instructions
- June 8, 2024
- RAB
Table of Contents
RAB HA4 HALED Modular Downlight
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE
REFERENCE.
RAB fixture must be wired in accordance with the National Electrical Code and
all applicable local codes. Proper grounding is required for safety. THIS
PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE
BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND
THE HAZARDS INVOLVED.
TO PREVENT ELECTRICAL SHOCK, POWER SHOULD BE TURNED OFF AT THE FUSE BOX BEFORE INSTALLATION. SAFETY WARNINGS:
- WARNING To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
- INSTALLATION SHOULD ONLY BE PERFORMED AFTER POWER TO THE FIXTURE HAS BEEN DISCONNECTED.
- These instructions shall be included on an information sheet packaged with each unit.
- This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
WHAT’S IN THE BOX
OPTIONAL ACCESSORIES
REQUIRED ACCESSORIES
INTERCHANGEABLE TRIM FOR 6’’ MODULE (HA6)
INSTALLATION
-
Turn power OFF from the fixture before installation
-
Use template inside box to cut hole in ceiling. (Fig.1)
-
Disconnect the fixture from driver box (Fig.2)
-
Mount the appropriate trim (Round or Square) on the module. Twist the trim to lock on the module securely. (Fig.3)
-
Open the driver box and remove the knockout(s). (Fig.4)
-
Insert the electrical supply cable through the knockout and secure with a terminal. Wire driver box (Fig.5) , white-white, black – black, green – green/ground.
-
Place all wiring and connections back into the box, close the cover and select desired CCT. (Fig.6)
-
Place the driver box into celling and connect the fixture to driver box . lifting both retention tabs upward. (Fig.7)
-
Push until the trim sits flush against the ceiling. (Fig.8)
TROUBLESHOOTING
- Check that the line voltage at the fixture is correct. Refer to wiring directions.
- Is the fixture grounded properly?
CLEANING & MAINTENANCE
CAUTION: Be sure fixture temperature is cool enough to touch.
Do not clean or maintain while fixture is energized.
- Do not open fixture to clean the LED. Do not touch the LED.
- Do not touch reflector.
- Do not clean any fixture surface with wood-base cleaning material such as paper towels or tissues.
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.
rablighting.com Tech Help Line e-mail
Visit our website for product info Call our experts: 888 722-1000 Answered
promptly – sales@rablighting.com
Free Lighting Layouts
Answered online or by request
© 2022 RAB LIGHTING Inc.
Cranbury,. New Jersey08512 USA
HALED Light
Engine-lN-0522
Read User Manual Online (PDF format)