CITEL N121102k Parafoudre Coaxial HF RF Coaxial Surge Protector Installation Guide

June 8, 2024
CITEL

CITEL N121102k Parafoudre Coaxial HF RF Coaxial Surge Protector

CITEL-N121102k-Parafoudre Coaxial-HF-RF-Coaxial-Surge-Protector-
PRODUCT

Technical Data

CITEL-N121102k-Parafoudre Coaxial-HF-RF-Coaxial-Surge-
Protector-FIG- \(1\)

Male and Female 4.3/10 connectors are also available

Application example

Location

P8AX surge protector must be installed in series on the coaxial cable:

  • A. At the entrance of the building or cabinet.
  • B. At the tower top, close to antenna interface, if necessary.

For critical applications, an additional protector near the equipment to be protected is recommended.CITEL-N121102k-Parafoudre Coaxial-HF-RF-Coaxial-
Surge-Protector-FIG- \(2\)

Installation

Earthing over BK-xxxCITEL-N121102k-Parafoudre Coaxial-HF-RF-Coaxial-
Surge-Protector-FIG- \(3\)

Earthing over well grounded PanelCITEL-N121102k-Parafoudre Coaxial-HF-RF-
Coaxial-Surge-Protector-FIG- \(4\)

Earthing over cable shoeCITEL-N121102k-Parafoudre Coaxial-HF-RF-Coaxial-
Surge-Protector-FIG- \(5\)

Important notes

The following points must be strictly observed to insure the efficiency:

  • A. Equipotentiel bonding network: all the grounding conductors of the installation must be interconnected and connected to the installation network.

  • B. Optimized connection of the protector to the grounding network:

    • To reduce the residual voltages during lightning discharge currents, the connection of the protector to the ground network must be as short as possible (less than 50 cm) and has a proper cross section (at least 4mm²).

    • The “Feed-through mounting” type fits perfectly all these requirements.
      WARNING : for good contact, remove carefully all paintings or insulating coatings.

    • The product is rated IP66 (Protected from high pressure water jets from any direction). To enhance the existing outdoor rating, seal tape can be added to coaxial connection during installation

Maintenance

CITEL-N121102k-Parafoudre Coaxial-HF-RF-Coaxial-Surge-
Protector-FIG- \(6\)

ATTENTION

  • Installation must be performed only by electrically skilled operator.
  • National electrical installation rules must be followed.
  • The unit must be used only as surge protector and according the conditions described in this document.
  • The device must be selected according to the application and the voltage (see Table 1).
  • If the signal is interrupted, then the unit is defect and must be replaced

This document could be modi ed without notice. Updated Information on Website

www.citel.us
www.citel.us
www.citel.com.cn
www.citel.ru
www.citel.in

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals