“`html
Specifications
- Model: RRU71717M RRU51717M RRU31717M
- Size: 17 x 17 x 2.5mm
Product Information
General Description
The Ex10 UHF RFID Module(1-Port) is based on the E310 chip
design, Gen2 Extension Ready, with ultimate small size, low power
consumption, and low cost. It comes in an SMD form factor with a
maximum RF output of 27dBm, making it suitable for various small
desktop and mobile devices. The module supports ISO18000-6C(EPC
C1G2) protocol tags and offers excellent multi-tag anti-collision
functionality.
Features
- Self-intellectual property
- Supports IMPINJ E710/E510/E310 designs
- Frequency band: 865~868MHz/902~928MHz
- RF output power up to 27dBm (adjustable)
- Effective distance up to 6m*
- Maximum inventory speed up to 1000pcs/s (using E710) or
600pcs/s (using E510) or 350 pcs/s
Characteristics
Absolute Maximum Ratings:
- Power Supply: -20 ~ +65 V
- Operating Temp: -40 ~ +85 °C
- Storage Temp: -40 ~ +85 °C
Electrical and Mechanical Specification
Under TA=25°C, VCC=+5V unless specified:
- Power Supply: 3.6-5V
- Current Dissipation: 360mA (active), 67mA (standby)
- Frequency: 865~868MHz (ETSI), 902~928MHz (FCC)
- RF Output Power: up to 27dBm
- Receive Sensitivity: -74dBm (using E310), -81dBm (using E510),
-87dBm (using E710)
Interface
NO. | SYMBOL | COMMENT |
---|---|---|
1 | VCC | Power Supply |
Mechanical Data
(UNIT: mm)
Product Usage Instructions
FAQ
Q: Can I customize the frequency band for this
module?
A: Yes, frequency customization is optional for
the Ex10 UHF RFID Module.
“`
Ex10 UHF RFID Module(1-Port)
RRU71717M RRU51717M RRU31717M
Ex10 UHF RFID Module(1-Port)
Model: RRU71717M RRU51717M RRU31717M
Size: 17 x 17 x 2.5mm
Page 1 Total 4
Ex10 UHF RFID Module(1-Port)
RRU71717M RRU51717M RRU31717M
GENERAL DESCRIPTION
Based on the E310 chip design, Gen2 Extension Ready, ultimate small size, low
power consumption, low cost, SMD form factor, maximum RF output of
27dBm,making it the best choice for various small desktop and mobile
devices.Additionally, sub-versions based on the E710 and E510 are available.
FEATURES
Self-intellectual property; Designed with IMPINJ E710/E510/E310 and support
ISO18000-6C(EPC C1G2) protocol tag,
featuring excellent multi-tag anti-collision functionality;
865~868MHz/902~928MHz frequency band(frequency customization optional); FHSS
or Fix Frequency transmission; RF output power up to 27dbm(adjustable);
Positioning holes used to facilitate connection to external antenna; Effective
distance up to 6m*(with external 3.81dBi antenna and tag E41); Maximum
inventory speed up to 1000pcs/s (using E710) or 600pcs/s (using E510) or 350
pcs/s
(using E310); Tag buffer size up to 1000PCS@96bits EPC; Low power dissipation
with single +3.6~5.5VDC power supply; Support RSSI; Capable of continuous
operation for 24 hours×365 days; Support on-the-site firmware upgrading.
Effective reading distance and tag interrogation speed are directly related to
the antenna, tags, and the working environment.
CHARACTERISTICS
Absolute Maximum Ratings
ITEM
SYMBOL
Power Supply
VCC
Operating Temp
TOPR
Storage Temp
TSTR
VALUE 6
-20 ~ +65 -40 ~ +85
Page 2 Total 4
UNIT V
Ex10 UHF RFID Module(1-Port)
RRU71717M RRU51717M RRU31717M
Electrical and Mechanical Specification
Under TA=25,VCC=+5V unless specified
ITEM
SYMBOL
MIN
TYP
Power Supply
VCC
3.6
5
Current Dissipation
IC(active) IC(standby)
360
Frequency
FREQ
–
67(standby)
865~868(ETSI) 902~928(FCC)
RF Output Power
PRF
Receive Sensitivity
SR
5
-74(using E310) -81(using E510) -87(using E710)
MAX 5.5 600(27dBm)
27
UNIT V mA
MHz dBm
dBm
INTERFACE
NO. SYMBOL
1
VCC
2
GND
3
EN
4
GPO2
5
GPI1
6
GPI2
7
RXD
8
TXD
9
RST
10
GPO1
11
GND
12
ANT
13
GND
14
GND
15
NC
16
NC
17
NC
18
NC
19
VOUT
20
GND
COMMENT Power Supply
Ground Enable, active high General Output 2 (3.0V TTL level) General Output 1
(3.3V TTL level compatible) General Output 2 (3.3V TTL level compatible)
Serial data Input (3.3V TTL level compatible) Serial data Output (3.3V TTL
level compatible) Module reset, active low General Output 1 (3.0V TTL level)
Ground Antenna Ground Ground Reserved Reserved Reserved Reserved 3.0V output
(max. 20mA) Ground
Page 3 Total 4
Ex10 UHF RFID Module(1-Port)
MECHANICAL DATA (UNIT: mm)
RRU71717M RRU51717M RRU31717M
Application Information
1. When designing fixed reader, please take care of heat sinking and remember
to make sure the heat sinker of the module is closely and stably attached to
the reader’s bottom plate; 2. Please refer to User’s Manual for detailed
protocol description.
Remark: 1. Specifications are subject to change, please pay attention to our
latest version. 2. Shenzhen RoyalRay Science and Technology Co., Ltd. reserves
the right to the final interpretation of the above terms.
Page 4 Total 4
Shenzhen RoyalRay Science and Technology Co., Ltd Tel: +86 755 25531562 25606619 25636705
Website: www.rr-rfid.com
Fax: +86 755 25531562 Email: support@rr-rfid.com market@rr-rfid.com
ADD: Suite FC, 4F, A1 Building, Xiufeng Industrial Park,NO.2 Xiufeng Road, Longgang District, Shenzhen, P.R.C.
FCC Radiation Exposure Statement The modular can be installed or integrated in mobile or fix devices only. This modular cannot be installed in any portable device, for example, USB dongle like transmitters is forbidden. This modular complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This modular must be installed and operated with a minimum distance of 20 cm between the radiator and user body. If the FCC identification number is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. This exterior label can use wording such as the following: “Contains Transmitter Module FCC ID: 2BA5U-RRU31717M or Contains FCC ID: 2BA5URRU31717M” When the module is installed inside another device, the user manual of this device must contain below warning statements: 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. The devices must be installed and used in strict accordance with the manufacturer’s instructions as described in the user documentation that comes with the product. The host product manufacturer is responsible for compliance to any other FCC rules that apply to the host not covered by the modular transmitter grant of certification. The final host product still requires Part 15 Subpart B compliance testing with the modular transmitter installed. The end user manual shall include all required regulatory information/warning as shown in this manual, include: This product must be installed and operated with a minimum distance of 20 cm between the radiator and user body.
FCC Statement This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures: -Reorient or relocate
the receiving antenna. -Increase the separation between the equipment and
receiver. -Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected. -Consult the dealer or an experienced
radio/TV technician for help. To assure continued compliance, any changes or
modifications not expressly approved by the party. Responsible for compliance
could void the user’s authority to operate this equipment. (Example- use only
shielded interface cables when connecting to computer or peripheral devices).
This equipment complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference, and (2) This device must
accept any interference received, including interference that may cause
undesired operation.
FCC Radiation Exposure Statement: The equipment complies with FCC Radiation
exposure limits set forth for uncontrolled enviroment. This equipment should
be installed and operated with minimum distance 20cm between the radiator and
your body.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>