KAYOBA 50461 Solar Powered Bilge Pump Instruction Manual

June 4, 2024
KAYOBA

KAYOBA 50461 Solar Powered Bilge Pump

KAYOBA-50461-Solar-Powered-Bilge-Pump-PRODUCT-IMAGE

SAFETY INSTRUCTIONS

Read the operating instructions carefully before use!
Save them for future reference.

  • The pump is designed to remove standing fresh or salt water. If the pump is used for a fluid other than water, the.user is responsible for any consequential damage.
  • The pump is spark protected.
TECHNICAL DATA
  • Connection 29mm
  • Flow 60 I/min
  • Dimensions B130xH150xD110 mm
  • Power cord length 1m
  • Voltage 12 V
  • Output power 108W
DESCRIPTION

KAYOBA-5KAYOBA-50461-Solar-Powered-Bilge-Pump-010461-Solar-Powered-Bilge-
Pump-01

  1. Cable

  2. Cable connection

  3. Pump housing

  4. Seal

  5. Motor

  6. Cover

  7. Oil seal

  8. Impeller

  9. Lock ring

  10. Pump cover

  11. Self-tapping screw

  12. Strainer bas

  13. Pump

  14. To the outlet above the waterline

  15. Screw

  16. Strainer with snap fastener

  17. Adapter

  18. Switch

INSTALLATION

Install the pump

NOTE:

  • The bilge pump must be installed at the lowest part of the hull.
  • The strainer base must be installed correctly before the pump is installed and started.
  1. Loosen the strainer base from the pump by pressing in the snap fasteners on the side of the pump.
  2. Position the strainer base so that the outlet hose can be connected at a suitable angle.
  3. Screw the strainer base in place according to the description below:
    • Installation on wood: fasten with stainless steel screws.
    • Installation on glass fibre: first install a piece of wood and then secure the strainer base to the wood with stainless steel screws.
  4. Install the pump on the strainer base using the two snap fasteners.
Conned the hose

NOTE:

  • The hose should be routed horizontally or upwards, without loops or bends where water can stagnate, so that the hose can be emptied completely.
  • For most installations, a hose with an 19 mm ID should be routed through the hull to give maximum pump flow. The pump will not be damaged if connected to a hose with a smaller diameter. However, the flow will be less.
  1. Connect a hose with a 19 mm ID to the outlet connector and secure with a stainless steel clip.
  2. Place the hole for hose routing through the hull at least 30 cm above the waterline, to prevent water from entering when the pump is turned off.
Cable routing

NOTE:

  • Use cables with a cross sectional area of at least 1.3 mm2
  • If the pump is placed more than 6 m from the battery, the cables must have a cross sectional area of at least 2.1 mm2
  • Conductors with a too small cross section can overheat and cause a voltage drop and reduced pump capacity.
  1. Place all cable connections as high as possible from the water level. Protect using a marine-approved sealant.
  2. Secure the cables with insulated clips or plastic cable ties.
  3. Fit the positive cable from the battery with a fuse.
    • The panel switch with integrated fuse holder can be used.
    • Only use a fuse of the correct size.
  4. Connect the pump’s brown connector to the positive battery terminal. The pump must be connected with the correct polarity, otherwise it will run backwards.
  5. Check that the impeller rotates in the direction indicated by the arrow on the pump base by looking into the inlet opening. Never insert your fingers or other objects in the inlet opening.

KAYOBA-50461-Solar-Powered-Bilge-Pump-4

  1. Fuse
  2. Brown cable
  3. Battery
  4. Earth
  5. Pump

MAINTENANCE

TROUBLESHOOTING

Problem            Possible cause       Action

Small flow| Clogged valve| Clean the outside of the strainer and clear the area around the impeller, if necessary.
---|---|---
Blocked outlet pipe. Backwash the pipe to clear it.

Low battery voltage. Check the battery voltage and charge the battery, if necessary.

| Creased outlet hose.| If the hose must be rerouted with sharp bends, use a hose that will not crease.
The pump gives no water| Cable connections| Check that all the connections do not show signs of corrosion. Carefully pull each conductor to ensure it is correctly fitted. Make sure that no cables hang down into the water.
Tripped fuse| Check that the fuse is the right size. Check through the inlet opening that the impeller is not blocked.
Cable overheated Melting insulation| Combination of blocked impeller and wrong fuse size.| Check that the impeller is not blocked and rotates freely.

Use a fuse of the correct size. Replace damaged cables and/

or switch.

---|---|---
The fuse trips repeatedly| Incorrect fuse size or blocked impeller.| Use a fuse of the correct size.
Check that the impeller is not blocked by fishing line or the like.

STORAGE

  • The pump is not affected by temperatures below O °C, but it cannot be used if ice-bound or surrounded by ice.
  • Never try to start the pump if it is ice-ice-bound or surrounded by ice.