RAB MVS-OD Microwave Motion Sensor Instructions

June 9, 2024
RAB

RAB MVS-OD Microwave Motion Sensor

FEATURES

RAB-MVS-OD-Microwave-Motion-Sensor-FIG-7

PERFORMANCE

Operating voltage 12 ± 2V DC
Operating current 30mA
Output DIM 0-10V
Stand-by power <0.5W
Brightness 70%/80%/90%/100%
Detection area 25%/50%/75%/100%
Hold time 5s/10min/30min/60min
Daylight threshold 10Lux/30Lux/50Lux/100Lux/Disable
Stand-by period 5s/30min/60min/+∞
Stand-by dimming level 10%/20%/30%/50%
Microwave frequency 5.8GH ± 75MHz
Microwave power <0.5mW
Detection angle 30-150°
Control line Pink: 12V ; purple: DIM+ ; Gray: GND/DIM-
Mounting height Max 15M (ceiling mounted)
Detection range Max Ø15m (ceiling mounted) Max 20m(wall mounted)
Operating temperature -25°C~+60°C
IP rating IP65

MVS SENSOR FACTORY SETTINGS

BRIGHTNESS 100%
HOLD TIME 1 Minute
DAYLIGHT Disabled
SENSITIVITY 50%
STAND-BY DIMMING LEVEL 20%
STAND-BY TIME 1 Minute

DIMENSIONS

  • Weight: 0.14lb

WIRING DIAGRAM

DETECTION COVERAGE

RAB-MVS-OD-Microwave-Motion-Sensor-
FIG-4

LUX ON-OFF

Sensor automaticaly turns off light when ambient brightness exceeds preset lux level. Following preconditions apply to use the Lux On-
Off function:

  • Stand-by period: +oo
  • Stand-by dimming level: 109%, 206, 309% or 509%
  • Daylight threshold: 10Lux, 30Lux, 50Lux or 100Lux

RAB-MVS-OD-Microwave-Motion-Sensor-FIG-3

  • When ambient brightness is higher than preset lux level, light automatically turns off
  • When motion detected while ambient brightness is insufficient, light DIMs 100%
  • Light dims to stand-by level when there is no motion detection after hold time
  • When ambient brightness is higher than preset lux level, light automatically turns offRAB-MVS-OD-Microwave-Motion-Sensor-FIG-2

INSTRUCTIONS

RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.comRAB-MVS-OD-Microwave-Motion-Sensor-
FIG-1

REMOTE FOR MVS-OD SENSOR

Remote Display Area

  • BRIGHTNESS (70%/80%/90%/100%)
  • DAYLIGHT (10lx/30lx/50l/100lx)
  • STANDBY DIM (10%/20%/30%/50%)
  • HOLD TIME (10S/1min/10min/30min)
  • SENSITIVITY (20%/50%/75%/100%)
  • STANDBY TIME (+ ∞/1min/30min/60min)

Button Setting Area

  • ON/OFF (Long press the “ON/OFF” button until the brightness indicator light is on (First-row).
    Press to turn on or turn off the fixture.)

  • BRIGHTNESS (Press to adjust dimming level 70%/80%/90%/100%. pre-set)
    Note: MVS Sensor Brightness factory setting is 100%.

  • SEND (Press to save settings after each change. The indicator light confirms the save setting.)
    Note: MVS Sensor factory setting hold time is 1 minute.

  • DAYLIGHT (Long press the button until the daylight indicator light is on. Press to adjust daylight threshold 10lx/30lx/50lx/100lx.) Note: MVS Sensor daylight threshhold factory setting is disabled.

  • SENSITIVITY (Press to adjust sensitivity 20%/50%/75%/100%.)
    Note: MVS Sensor sensitivity factory setting is 50%.

  • STANDBY DIM (Press to adjust stand-by dimming level 10%/20%/30%/50%.)
    Note: MVS Sensor standby dimming level factory setting is 20%

  • STANDBY TIME (Press Standby Dim to adjust time + ∞ / 1min, 30min, 60min).
    Note: With Daylight activated , choose:

    • Unlimited stand-by time (+ ∞): Default mode: light control, turn on/off: choices: 10/50 lux, 30/100 lux 100/200 lux; or
    • Light threshold mode choices: 10 lux, 30 lux, 100 lux (if light level is < preset lux and motion is detected, light will turn on at present lux).
      note: MVS Sensor standby dimming level factory setting is 1 minute.
  • RESET (Press “RESET” button, products with DIP switch will be controlled by DIP switches; Otherwise all the setting will change is Brightness 70%/ Hold time 10s/Sensitivity 20%/ Daylight threshold disable/ Stand-by dimmer level 10%/ Stand-by time + ∞ .

  • TEST The button “TEST” is for testing purpose after debugging. Pressing this button, the sensor goes to test mode (hold time is only 3s).

    • Press to increase the brightness (0%-100%).
    • Press to reduce the brightness (100%-0%).

PROGRAMMING GUIDELINES

  1. If you want to send a setting, it will only work if the remote control is on. If you do not press any button within 10 seconds, the indicator light will go out.

  2. When using “ON/OFF” button, the rest of the buttons except the “ON/OFF”,
    “BRIGHTNESS” and “SEND” buttons will be disabled.

  3. When using “TEST” button, the rest of the buttons except the “TEST”, “SENSITIVITY” and “SEND” button will be disabled.

  4. Every change requires you to press the “SEND” button to save.

  5. Because of the power supply DIMMING ratio difference, when using different power, “BRIGHTNESS” and “STANDBY DIM” adjust percentage of the power will have difference with the measured power.

© 2022 RAB LIGHTING Inc. MVS-OD SENSOR
REMOTE CONTROL – IN – 0322 73724-RAB

rablighting.com
Visit our website for product info

Tech Help Line
Call our experts: 888 722-1000

e-mail Answered promptly – sales@rablighting.com

Free Lighting Layouts Answered o

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals